How to restart a computer automatically after a power outage
Open the PC's BIOS or UEFI settings and select Power On for the setting that controls what happens when input power returns. Then test a complete power interruption and confirm that the workload comes back.
Set the firmware to power on
- Find the system or motherboard model and open its firmware manual. Enter setup using the key given for that model.
- Look in the power settings for the AC recovery option. On a Dell OptiPlex 5050 Tower the manual lists Power Management → AC Recovery. On documented Intel NUC Aptio V firmware the setting is Power → Secondary Power Settings → After Power Failure.
- Choose Power On and save your changes. Last State restores the previous power state, so a PC that was already off can stay off when power returns. Use Power On when it must start in either case.
Bench-test the full restart
Use a bench PC or an approved maintenance window. Shut down cleanly, remove input power using the equipment's service procedure, then restore it. The PC should boot without anyone touching the power button. Record the model, firmware setting and result.
For an unattended workstation, repeat the check in the intended operating mode. Verify that the OS starts, network access returns and the application reaches its ready state. An illuminated power indicator or a sign-in screen only confirms part of that sequence.
Find where restart stops
- Power reaches the PC and it stays off. Reopen firmware setup and verify the saved setting. If the option is missing, check the manual for that board and firmware version.
- The site lost utility power but the PC never lost input power. A UPS can ride through the outage. The firmware reacts to restored power at the PC's input. If the UPS shut down its output, verify its own restart behavior.
- Windows starts and the application is absent. Check whether the program is configured to start at sign-in or whether the vendor supplies a service that starts at boot. Test under the account and permissions the workstation uses.
When comparing replacement computers, specify the required behavior and ask for the exact firmware setting and a verified power-cycle result. See how we verify industrial sourcing requirements.
Dell OptiPlex 5050 Tower firmware options · Intel NUC Aptio V BIOS glossary