Practical guides for the people who build machines and keep them running: servo and stepper motion, drive and gearbox sizing, belts and couplings, linear guides, pneumatics, sensors and machine vision.
Use a two-position belt drive at 2:1 and 1:2: a 2-inch motor pulley into a 4-inch spindle pulley turns a 2800 rpm motor into 1400 spindle rpm with ideally doubled torque, and reversed it gives 5600 rpm with half torque. Overspeeding with the VFD to 100 Hz makes a calculated 11200 spindle rpm through the overdrive pair, usable only after the motor, belt, pulley and spindle bearing datasheets clear it.
Every machine in this library ends at an operator station. Industrial Monitor Direct builds the touch monitors and panel PCs that go there. Choose a configuration and see the live price.
Q-Series 15.6-inch industrial touch monitor
Hardware for machine control
Panel PCs, touchscreen monitors, fanless mini PCs and stainless enclosures, configured to the job at Industrial Monitor Direct.
A full rack decides a motion retrofit before any drive is chosen: count the slots and the enable, home, limit and fault points every axis adds, and replace the PLC when the demand exceeds what is free. The worked case needs three slots in a rack with none. The stepper command path is verified separately from the two servos, and the panel decision belongs in the same comparison.
Heat with the shaft stopped is holding current at work: an enabled pulse-and-direction driver feeds both windings continuously, and copper loss P = I²R turns that current into heat before a single pulse arrives. Fix it at the driver with idle-current reduction and a datasheet temperature check before you change the PLC's ready and enable wiring.
The 5 V to 2 V collapse means the servo's motor current is flowing through the microcontroller's logic node. A PWM pin supplies milliamps; a servo at startup draws its stall current. Feed the servo power terminals from a supply sized for at least the stall current, and run only the command signal to the pin.
Yes: a permanent magnet DC servo motor runs on a conventional armature-controlled DC drive, but only with the drive's internal field function switched off (P82 = 0 on the 6RA70 family), the shaft mechanically locked before armature current-controller optimization (P51 = 25), and speed-controller optimization (P51 = 26) run afterward. A PM motor keeps its field, so an unsecured shaft can run away during tuning.
Choose the counter mode before you touch a wire: single-channel counting turns a 1000 P/R encoder into 1000 counts per revolution, while quadrature x4 turns the same encoder into 4000. Then verify the encoder's output circuit — driver type, polarity and common — against the counter input's voltage class and wiring terminals from the PLC manual.
Sensors, encoders and machine vision on the machine
A single-turn absolute encoder identifies position only within one motor revolution. A linear axis driven through a ball screw spans many revolutions across its travel, so the controller cannot tell which revolution the motor is in and the machine loses its absolute coordinate at power-off. Fit multi-turn absolute feedback, an absolute linear scale, or a defined reference run at every startup.
Sensors, encoders and machine vision on the machine
An Omron NJ can control a non-Omron servo drive only through an interface both devices document at the timing the axis needs: verified EtherCAT with the matching ESI file for coordinated motion, register communication for independent targets, or digital I/O triggering drive-resident moves. An ESI file cannot add EtherCAT hardware a drive lacks, and an Altivar accessory does not fit a Lexium 32.
A pulse-output stepper system is open loop: the controller's commanded position is its own count of emitted step pulses, and the quadrature encoder gives a separate measured position. Program the two as independent values, compare them in ladder logic after each move, and never reset the position counter or reload the motion profile between absolute moves — every target is an absolute position, so a reset turns each move into a fresh move from zero.
When absolute position keeps vanishing after a clean mastering pass, the mastering is not at fault: the battery-backed encoder is losing its zero, usually through a backup battery at the end of its roughly two- to three-year life. Measure the pack under load, replace it below its window, master once, then run the power-cycle retention test; position that still drifts with a healthy battery means the encoder itself is due for replacement.
An axis that stops a fixed increment past target on every repeat after a timing belt conversion is losing steps, not coasting. Convert the measured drift into motor full steps: about half a revolution per repeat points at the new belt drive losing synchronism, a few microsteps after each reversal points at direction setup time, and drift only when two axes run together points at the shared 24 VDC supply.
Exactly one controller owns the position loop: it compares the demanded position with the 4-20 mA feedback and commands the valve. The PLC's 0-10 V output is either a scaled position reference for that controller or the valve command from the PLC's own PID, never both devices regulating at once. Decide which before scaling, wiring or tuning any gain.
An EtherCAT stepper drive can produce motion today as a cyclic IO device: the master exchanges PDOs only and the drive's internal interpolator builds the profile. A full CiA 402 motion axis needs acyclic CoE mailbox access that the master, the drive's object dictionary and the motion planner all provide. And an axis that enables without visibly moving is usually a scaling problem: at 256 microsteps a 200-step motor holds 51,200 counts per revolution, so command that many counts and expect exactly one turn.