Troubleshooting
Diagnosing a Hydraulic Winder That Stalls Under Tension
Short answer
When raising the tension command stalls the drive roll of a hydraulic winder, first measure the speed-valve command: if the controller is already at full output, the fault is hydraulic capacity — pump flow, relief setting, filter or internal leakage — not control logic. A top speed of 75 against a documented 150 m/min confirms the drive motor is getting about half its designed flow.

On this page
When a two-roll hydraulic winder stalls as you raise the tension command while the braked roll keeps unwinding, the control side is asking for more differential pressure than the power unit can deliver. Put a meter on the speed-valve command first: if the analog output already sits at full scale while the drive stalls, the fault is hydraulic capacity — pump flow, relief setting, filter condition or internal leakage — not your program. A top speed of 75 m/min against a documented 150 m/min rating says the same thing from the other direction: the drive motor is getting about half the flow it was designed for. Fix the hydraulics before writing any closed loop.
What the weight command actually controls #
On this class of winder the speed channel and the tension channel are separate. The speed output drives a proportional flow valve whose card closes a position loop on the spool: you give it a voltage and the card holds the spool there. Nothing in that loop senses cloth speed or cloth tension. The weight output drives a proportional pressure-reducing valve on the brake side with no feedback of its own.
Raising the weight command raises back-pressure on the roll being unwound, and web tension is the difference between what the drive roll pulls and what the brake holds back. The manual scales that setting 0–50 kg, so the tension command is expressed as a tension, not a pressure. One manufacturer's electro-proportional reducing-valve family is documented for remote pressure control up to 285 bar (4,000 psi), several times any textile winder's working pressure — so the valve's rated ceiling is rarely what runs out. The pump and the relief behind it are.
The first check: is the command already at 10 V #
Measure the speed-valve command where it lands, at the proportional card terminals, while the machine is actually stalling. The card input is a 0–10 V signal, so a saturated controller reads full scale. If you read full scale there and the drive still stops as the weight command climbs, the program is doing everything it can and the deficit is hydraulic — work the checklist below. If you read less, the limit is yours: an output clamp, a ramp that never finishes, a scaling error between the m/min setpoint and the volts, or an integrator wound up against a loop it cannot win. Confirm the prop card healthy input stays made through the stall; if it drops, the card is folding back.
Driving the card input directly from a signal source at full scale, with the controller offline, isolates card and valve from the program. Treat that as a live-machine test: guards closed, everyone clear of the rolls and the web path, and know which way the valve moves before you force it, because the drive will answer at full authority.
Hydraulic causes in order of cost to check #
The symptom set — drive roll stops, brake roll keeps unwinding, top speed far below rating — fits several hydraulic faults. Check them in this order, cheapest first, and confirm each before moving on:
- Filter restriction. A clogged element caps the flow that sets top speed and starves the pump exactly when the brake raises load pressure. Confirm with the pressure drop across the element, the clogging indicator if one is fitted, or by inspecting the element.
- Relief or unloader set low, or passing. The relief is the ceiling on drive-line pressure; if it cracks open below brake pressure plus the tension margin, the drive motor stalls there, and the flow it dumps is the speed you lost. Confirm with a gauge in the drive line at full command and watch where pressure plateaus.
- Pump not delivering full flow. A variable-displacement pump not reaching full stroke, or a worn pump losing volumetric efficiency, delivers a fraction of its nameplate at full command. Confirm by measuring delivery against the pump nameplate and by checking case-drain flow: drain flow that grows with pressure is wear leaving the pump.
- Drive-motor internal leakage. A hydraulic motor slipping internally slows and then stalls precisely as differential pressure climbs with the weight command. This winder swaps which roll drives on every pass, which gives you a clean test: if the stall follows the drive circuit across several reversals, the supply is at fault; if it follows one physical motor, that motor is bypassing internally, and its case drain will run hot and heavy.
- Air in the oil. Aeration makes response spongy and the pump noisy, and output can collapse under load. Confirm at the reservoir for foam and bleed the circuit's high points.
- S1 not fully open. S1 is the solenoid shut-off in the brake pressure-regulating branch; a partly open or failing shut-off scrambles brake pressure independently of the weight command. Confirm by energizing it, verifying it opens fully, and watching a gauge in the branch.
Worked example: 75 of 150 m/min at full command #
Inputs, each with its source: documented maximum cloth speed 150 m/min, from the translated OEM manual; achieved cloth speed 75 m/min at full speed command with minimal brake, read from the machine's own encoder on the free-running roll; speed command range 0–10 V and weight setting range 0–50 kg, from the machine's I/O list and the same manual.
The rule in words: with a fixed-displacement hydraulic motor and fixed gearing from motor to roll, cloth speed is proportional to the flow reaching the drive motor, so the ratio of achieved speed to documented speed equals the ratio of delivered flow to designed flow.
The arithmetic:
75 m/min ÷ 150 m/min = 0.50
At full command the drive motor receives about half the flow the machine was designed around. At the full weight setting the web tension is 50 kg × 9.81 m/s² ≈ 490 N — the pull the drive branch must sustain on top of friction and acceleration.
That 50% is a calculated example for these inputs, not a measured flow. The decision: with full-scale voltage verified at the card, a top speed within about 10% of 150 m/min (a rule of thumb covering slip and tolerance) would be tuning territory; half of it is not. Measure pump delivery, relief setting and case drain first, and expect to find one of the hydraulic causes above.
The S1 and S4 valves on the schematic #
S1 is drawn as a solenoid shut-off that isolates the brake pressure-regulating branch: closed, the weight command has nothing to act on; failing part-open, brake pressure wanders for reasons the program never commanded. S4 is the direction valve that swaps feed between the two roll motors, exchanging which roll drives and which brakes at each pass reversal — the same reversing job as the circuit used for auto-reversing a double-acting hydraulic cylinder. One caution when reading the OEM drawing: Italian schematic practice can render a reducing valve where you expect a sequence valve, so confirm each valve's function by energizing one solenoid at a time and watching a gauge rather than trusting the symbol.
Closing the loops after the hydraulics are fixed #
Once the drive reaches its documented speed under full brake, close the loops. Speed is a straightforward PI loop: encoder pulses from the free-running roll give cloth speed in m/min, and the output scales to the speed-valve card. Tension has no feedback on this machine — the encoder counts metres, not newtons — so the weight channel stays an open-loop command until you fit pressure transducers on the drive and brake lines and regulate the differential directly.
Two things to remember while tuning. A loop can only share out the pressure and flow that actually exist; whether a PLC-driven proportional valve can stop a hydraulic ram repeatably depends on that margin, and a winder is no different. And as the wound roll builds, its growing diameter raises the torque needed to hold the same tension, so the weight command needs a diameter term; calculating roll diameter from encoder pulses supplies it.
Questions asked
Why does the braking roll keep unwinding when the drive roll stalls?
Because the two branches stay pressurized independently. When the drive motor can no longer hold differential pressure it stops, while the brake-side reducing valve keeps pressure on the unwinding roll, so that roll keeps turning and dumps loose material. Seeing both at once is the clearest on-machine evidence that the drive branch has run out of capacity rather than the tension command being wrong.
What do the inputs marcia, marcia lenta and marcia pendolomata mean?
Marcia is the run command, marcia lenta is slow run or jog, and marcia pendolomata is the pendulum mode that reverses the winding direction after each pass so material shuttles through the process. They arrive from the other controller, so if they never energize, measure their voltage levels and check the healthy-signal handshake between the two PLCs before looking anywhere else.
Can the encoder close the tension loop by itself?
No. The encoder reports cloth speed and accumulated metres; it cannot see tension. You can detect a stall as a speed collapse and back off the weight command, but true tension control needs pressure transducers on the drive and brake lines so the controller regulates the pressure differential directly. Until then the weight setting is a calibrated command, not a measurement.
How should the speed loop be tuned once the hydraulics check out?
Start with proportional gain alone, low, and raise it until cloth speed follows a step without oscillating. Add integral only as much as needed to erase steady-state error at constant setpoint, and leave derivative at zero because speed derived from pulse counting is stepped. Clamp the output at the valve card's full-scale voltage so saturation is visible on the screen the moment it returns.