5-Phase Stepper Motor Winding Sequence from Ten Leads
Short answer
Ten leads mean five separate windings you can find with an ohmmeter; the running order comes from the voltage each winding generates as you turn the shaft. Map without power, confirm with a current-limited step test, and never open the motor.

On this page
- What the ten leads tell you before any test
- Map the five windings with a resistance matrix
- Read the phase order from generated voltage
- Confirm with a current-limited step test
- Worked example: resistance matrix for a motor with 3.0 ohm windings
- Why the motor stays closed
- The decision for each case
- Questions asked
A ten-lead, five-phase stepper with an unknown winding order does not need to be opened or guessed. The concrete method: measure resistance between all 45 lead pairs to find five isolated winding pairs, then rotate the shaft in one recorded direction and read the cyclic electrical order from the zero crossings of the voltages the windings generate against one fixed reference winding. Confirm the result with a current-limited step test, and leave the motor closed, because opening a permanent-magnet rotor can partially demagnetize it and permanently cut the available torque. The resistance map takes minutes, the generated-voltage sweep a few more, and both need nothing but a multimeter, a two-channel oscilloscope and temporary lead labels.
What the ten leads tell you before any test #
Ten wires and five phases mean each winding has both ends on the connector, so the wire count alone guarantees no internal junction. Calling the arrangement delta needs checking against measurements: five isolated windings let you build the delta or pentagon network outside the motor, and some five-phase motors arrive with the pentagon connection wired internally and only five leads brought out. Which topology you have decides which driver stage can run the motor and which bench tests are valid.
Manufacturer data stays the first choice, because it gives the lead assignments, the connection arrangement and the rated winding current together. For the pentagon connection, Oriental Motor publishes a lead-identification document that includes the improved step sequences for that network; if your motor traces to a datasheet, use it and skip the bench work. If not, the procedure below recovers the map without applying drive power.
Map the five windings with a resistance matrix #
- Disconnect the motor from the driver and remove any external links between leads. Record the connector orientation and any existing wire markings first.
- Label every lead temporarily, 1 through 10.
- Measure resistance between every lead combination, 45 pairs in total, and record the readings in a 10 by 10 matrix. Do not rely on a continuity buzzer alone; the resistance value itself separates a winding from a short or a partial internal path.
- Five pairs that read the winding resistance to each other and open to every other lead are your five windings. Write the pairs down; the measured resistance is also your input for the current check later.
- If one lead shows a conductive path to several others, an internal junction exists. Draw the measured network as one terminal set and treat the motor as a five-lead machine, not five independent coils.
- Recheck any pair that reads far from the others, any open circuit, or any reading that drifts, before any powered test.
A resistance meter cannot tell which end of a winding is which, and it cannot reveal the spatial order of the phases. Both come from generated voltage.
Read the phase order from generated voltage #
The rotor's permanent magnets induce a voltage in each winding as the shaft turns; comparing those voltages winding by winding gives the electrical order without any drive current. It is the same logic a phase rotation tester applies to a three-phase motor, direction and order read from generated voltages, just applied winding by winding here. Before you spin the shaft, secure the motor so nothing walks away mid-test: clamp the body to the bench, keep loose leads away from the rotor and stator faces, and record the rotation direction before the first sweep. Then:
- Pick one winding pair as the fixed reference and mark its two leads plus and minus. These marks define the measurement direction only; they are not a proven motor polarity.
- Connect one oscilloscope channel across the reference winding and the second channel across the next winding, and check probe grounding before connecting either.
- Rotate the shaft repeatedly in one recorded direction, at whatever steady hand speed you can hold.
- Compare polarity and the timing of zero crossings. Peak amplitude varies with hand speed, so judge phase displacement from the zero crossings, not from peak voltage.
- Move the second channel to the next winding and repeat until all five windings have been measured against the unchanged reference.
- The result is a cyclic order of the five windings plus a polarity sign for each. That is the sequence your driver's excitation table needs.
Confirm with a current-limited step test #
Powered confirmation comes last, with the supply's current limit set at or below the nameplate winding current. At standstill, steady DC current is fixed by winding resistance through I = V/R, so choose the applied voltage that lands inside that limit; for the example winding below, that is 3.0 V for a 1.0 A limit.
- Energize one known pair. The rotor locks to that winding.
- Energize the next pair in your proposed order and watch the rotor: it should step the same small angle in the same direction every time.
- If the angle changes, doubles or reverses, the order is wrong. Go back to the generated-voltage map rather than hunting by trial and error at higher current.
Keep the test short: a wrong sequence can leave a winding energized and stalled, so a sequence fault and overheating can stack in the same run.
Worked example: resistance matrix for a motor with 3.0 ohm windings #
Inputs, all illustrative example values for this case, not a measured motor: ten unlabeled leads; a digital ohmmeter; an expected winding resistance of 3.0 ohm per winding, taken here as a round example number because the nameplate is unreadable; a bench supply limited to 1.0 A.
Rule in words: two leads belong to the same winding when the resistance between them equals the winding resistance and every other combination reads open. At standstill, steady DC current equals applied voltage divided by winding resistance, and copper loss equals current squared times resistance.
Arithmetic:
- 45 lead pairs are measured. Exactly five combinations, say 1–2, 3–4, 5–6, 7–8 and 9–10, read 3.0 ohm; the other 40 combinations read open. Five isolated windings are confirmed, and the delta or pentagon network will be formed outside the motor.
- Step-test voltage: V = I × R = 1.0 A × 3.0 ohm = 3.0 V. Set the supply to 3.0 V with the 1.0 A limit engaged.
- Copper loss while one winding holds: P = I² × R = (1.0 A)² × 3.0 ohm = 3.0 W.
Decision: with a current-limited supply set this way, the powered step test stays within the example winding's 1.0 A as long as 1.0 A is at or below the nameplate current. With no readable nameplate, keep the powered test to brief confirmations and treat the generated-voltage map as the primary evidence.
Why the motor stays closed #
Opening the housing to read the windings from inspection is the one move that can make the motor permanently worse: opening a permanent-magnet rotor can partially demagnetize it, and partial demagnetization is a recognized magnet fault in permanent-magnet machines, with the lost flux showing up as less available torque. Alnico rotors are the most prone; low-cost ceramic magnets less so; if you do not know which the rotor carries, do not open it. Close internal tolerances also make rotor removal likely to strike the stator and drag ferrous debris into the air gap. This article describes a bench identification method, not a repair or safety validation of the machine the motor feeds.
The decision for each case #
- Winding data or a traceable datasheet exists: use it. It resolves leadout, topology and rated current together, and the bench work becomes a quick confirmation.
- Ten leads and five isolated pairs on the meter: the network forms outside the motor. Take the cyclic order from generated voltage and build the driver's excitation table from it.
- Fewer leads out, or one lead conducting to several others: an internal junction exists. Draw the measured network, treat it as one terminal set, and use a driver topology that matches a pentagon or delta connection.
- No data and an unreadable nameplate: recover the map without power, keep powered tests short and current-limited, or fit a documented motor instead; the same bench checks apply as when reusing a salvaged 5-phase stepper.
Questions asked
How do I tell whether the five windings are joined inside the motor?
Measure the full matrix. If each lead shows resistance to exactly one partner and open to the other eight, the five windings are isolated and the delta or pentagon network is built outside the motor. If a lead conducts to several others, an internal junction exists: draw the measured paths and treat the motor as a single terminal network, the way internally connected five-lead motors behave.
Can I find the sequence without an oscilloscope?
Yes. Wire a two-leaded bicolor LED across each winding and turn the shaft in one direction: each LED flashes with polarity reversal as its winding passes the rotor poles, and the flash order across the five LEDs is the winding sequence. It is coarser than a scope, because the LED threshold and brightness hide small signals, so treat it as an ordering hint and confirm with the current-limited step test.
What keeps an identification test from cooking the windings?
The winding current, not the supply voltage. At standstill a steady DC test current is set by winding resistance, so applied volts divided by ohms is the current; keep that at or below the nameplate winding current with a current-limited supply. Copper loss is current squared times resistance. With a chopping driver the RMS current sets the heating, so a single peak reading understates it.
Why does the motor rock or run wrong even though the windings test fine?
A wrong excitation order drives the rotor to the wrong states, so it rocks, reverses or stalls while the windings stay cool; a cool motor can still have a sequence fault. Conversely, excess current overheats a correctly sequenced motor. A wrong sequence can also leave a winding energized and stalled, so both faults can appear at once, which is why the current limit stays set during the powered confirmation.