Selecting an Infrared Pyrometer for Conveyor Product Temperature

Sensors, encoders and machine vision on the machine Published 8 min read By AutomateDirectUSA engineering team

Short answer

For a 40-50 °C sintered-ore bed on a rubber belt, choose a fixed long-wavelength infrared pyrometer, not a disappearing-filament optical pyrometer. Mount it so the spot stays inside the bed across the full bed-depth swing, set emissivity against a contact probe near 0.95, and steam-test the installed sensor before arming the high-temperature alarm.

On this page
  1. The selection at a glance
  2. Why infrared, not optical pyrometry, below 60 °C
  3. Spot size, distance and the bed swing
  4. Set emissivity against a contact probe
  5. Steam and humid air over the load
  6. Worked example: spot size for a 600 mm mount over a full bed swing
  7. The output, the threshold and proving the chain
  8. The decision for each case
  9. Questions asked

Use a fixed long-wavelength infrared pyrometer to watch the sintered ore on the transfer conveyor — not a disappearing-filament optical pyrometer, which needs a glowing target and has nothing to compare when the load sits at 40-50 °C. Mount the sensor so its measurement spot stays fully inside the bed across the whole 300 mm bed-depth swing, set emissivity against a contact probe instead of trusting the factory preset, and steam-test the installed head before arming the alarm that protects the belt. Four decisions decide whether that high-temperature alarm is trustworthy: sensor family, optics and mounting distance, emissivity, and the vapor over the load. The table gives each decision and its pass condition; the sections that follow carry the detail, and a worked example sizes the spot across the swing.

The selection at a glance #

Six checks separate an alarm you can trust from one that cries wolf or stays silent. The table states each decision and its pass condition; the sections below carry the reasoning and the numbers.

Decision What to check Accept when
Sensor family Rated range against a 40 to 50 °C product with a below-60 °C alarm The rated range covers the product band; optical filament instruments are excluded outright
Optics and mount Datasheet spot curve at the farthest distance the bed swing allows The spot circle sits wholly on bed or belt at both bed depths
Emissivity Adjustable setting, and a contact probe for comparison Set by probe match on the load; a rough ore bed starts near 0.95
Head environment Ambient rating against heat and vapor at the mounting point The rating covers the real mounting spot, steam included
Output and threshold Head signal against the alarm input; threshold against the belt's rating A standard analog signal the monitor reads; threshold below the belt's rated maximum

Why infrared, not optical pyrometry, below 60 °C #

A disappearing-filament optical pyrometer compares the brightness of a glowing target with an internal lamp — the classic instrument for rolling-mill stock, which glows visibly and arrives at the same viewing position every pass. A cooled bed of ore at this application's operating temperature emits no visible light at all, so that family has nothing to compare and is ruled out here regardless of make or vintage. The question is not which brand but which physics: below the glow, only infrared radiometry works.

The infrared family reaches low temperature comfortably. One manufacturer's comparison table for its handheld condition-monitoring IR thermometers lists a -60 to +625 °C measuring range with ±2 % of reading or 2 °C accuracy, and a 0 to +50 °C ambient operating window; fixed-mount heads sit in the same territory. Take the numbers from the datasheet of the exact head, because two entries can sink the installation: a range that does not reach down to the product, and an ambient limit exceeded by the hot, wet air directly above a warm conveyor. Before any bracket is drilled, borrow a handheld instrument of the same family and read the load from several angles and distances — it is the fastest way to learn how the number behaves on your bed.

Spot size, distance and the bed swing #

A fixed infrared head averages everything inside its spot, and the spot grows with distance. The head must see only the conveyor: a circle that spills onto the frame, an idler or the floor beside the belt blends those surfaces into the reading, and the displayed temperature stops being the product's. Headline distance-to-spot ratios flatter the hardware — one manufacturer's application note on source-size checks measured a unit sold as 12:1 at a 38 mm field of view from a reference distance, an effective 7.9:1 — so size from the measured curve, not the boxed ratio. Then check both extremes of the bed swing: the viewed surface moves through the full swing between full bed and empty belt, and both distances must leave the spot wholly on the load. A larger spot is not automatically wrong; averaged over a lumpy bed it can steady the reading, but only while the circle stays inside it.

Set emissivity against a contact probe #

Emissivity sets how much of the surface's radiation actually reaches the sensor, and the reading is only as good as the setting. Most organic materials and rough, jumbled surfaces — an ore bed of small faces is exactly that — sit near 0.95, which is why many instruments ship preset there. Shiny or mirror-like surfaces are the opposite: they reflect their surroundings and can show the sensor a temperature that belongs to something else entirely. A sintered ore bed is on the friendly side of that line.

Set the value by the documented procedure rather than by faith: measure the viewed surface with a contact probe, then adjust the sensor's emissivity until the infrared reading matches the probe at the same patch, and repeat the comparison across the operating range rather than at one point. If relief contours make the reading wander — the failure one plant met when measuring powder straight from a dryer — change the geometry, as that plant did by fitting a plough to level the powder ahead of the instrument, instead of tuning emissivity against variation that is geometric rather than thermal. Emissivity, response and output scaling are the configuration half of pyrometer selection, and the guide on configuring infrared pyrometer measurement walks through those settings.

Steam and humid air over the load #

The field evidence on steam genuinely disagrees, and both sides deserve belief. Plants running over steaming loads report that ordinary rising vapor gives little trouble; the physics answer is that long-wavelength infrared loses transmission in humid air, which drags readings down. Both can be true at once, because the loss depends on path length and vapor density at the specific mounting point. So treat the optical path through steam as an unknown to be measured, not assumed: mount the head at the shortest practical unobstructed view, then test the installed sensor during the heaviest vapor the process ever produces. A stable reading on a dry day proves nothing about a wet one. If the reading jumps or tracks the vapor instead of the product, shorten the path, tilt the sight across the steam source, or relocate to where the load has already shed its moisture.

Worked example: spot size for a 600 mm mount over a full bed swing #

Inputs, each with its source:

  • Mounting distance from head to empty belt: 600 mm — an example choice for this case; the real frame fixes the real number.
  • Loaded bed raises the viewed surface 300 mm above the empty belt — the bed swing reported for this application.
  • Head optics: sold with a 12:1 distance-to-spot ratio; a manufacturer's application note measured its field of view at 38 mm from that same reference distance, an effective 7.9:1.

Rule in words: spot diameter grows in direct proportion to distance, so the spot at any distance equals the known spot scaled by the ratio of that distance to the distance where the spot is known.

Arithmetic:

  • Full bed: distance = 600 mm − 300 mm = 300 mm; spot = 38 mm × (300 ÷ 300) = 38 mm.
  • Empty belt: distance = 600 mm; spot = 38 mm × (600 ÷ 300) = 76 mm.
  • Cross-check: 600 ÷ 76 ≈ 7.9, the same effective ratio the note measured at the reference distance, as it must be when the spot scales linearly with distance.

Result: mounted 600 mm above the empty belt, this head averages a 38 mm circle on a full bed and a 76 mm circle on the bare belt.

Decision: the far-distance spot binds. Keep the 600 mm mount only if a 76 mm circle stays wholly inside bed or belt everywhere it passes the sensor and the smallest overheated region you must catch exceeds 76 mm. If the bed can run narrower where it passes, or a small hot chunk must trip the alarm, mount closer than 600 mm or select a head whose measured spot curve beats 7.9:1 at your distance — and read the curve, not the boxed ratio, because the nominal 12:1 measured 7.9:1 on the bench.

The output, the threshold and proving the chain #

Choose a fixed-mount head whose signal the alarm monitor already reads: fixed infrared heads commonly offer standard analog outputs such as thermocouple-style signals or a 4-20 mA current loop, and once the spot holds, the head is indifferent to surface level, belt speed and bed-depth changes. A pyrometer answers one question — surface temperature. If the same conveyor also needs speed for residence-time or rate totals, that is a different sensor doing a different job, and measuring RPM with a proximity switch on a pulley covers it.

Set the alarm threshold below the conveyor belt's maximum rated temperature, and take that limit from the belt supplier's datasheet — no pyrometer specification tells you what the belt survives. Then prove the whole chain under control: compare the head against a contact probe at a mid-range point and near the top of the operating band, requiring agreement within the head's stated accuracy (±2 % of reading or 2 °C on the documented example instrument), aim a handheld infrared thermometer at the same patch as a cross-check, and finally force a condition that crosses the threshold to confirm the alarm actuates. Mounting and aiming happen over a live conveyor: do the work under lockout per your site's procedure and the machine's risk assessment, and never reach toward a running belt to move a sensor or a sample.

The decision for each case #

  • Method: a fixed long-wavelength infrared pyrometer with a standard analog output and adjustable emissivity. A disappearing-filament optical pyrometer is the wrong family outright: it needs a visibly glowing target, and this load never glows.
  • Accuracy below 60 °C: the infrared family covers it, but the number earns trust only when the contact-probe comparison on the actual product agrees with the head within its stated accuracy across the 40 to 50 °C band. Agreement, arm the alarm; disagreement, fix emissivity or optics first.
  • Bed depth: it never corrupts the physics, only the geometry. Compute the spot at both bed heights — 38 mm and 76 mm for the example mount — and require both circles to sit wholly inside the load.
  • Steam: unproven until tested on the installed head. Shortest practical sight path, worst-vapor test, and if the reading follows the vapor rather than the product, shorten or move the path before the alarm goes live.

Questions asked

Is infrared accurate enough below 60 °C?

Yes, provided the head's rated range includes the operating band and you verify it on the product. Low-temperature infrared instruments span from below freezing to several hundred degrees, so a 60 °C alarm point sits well inside the family's reach. Measure the viewed surface with a contact probe at two points across the operating range and require agreement within the head's stated accuracy; if it agrees, the threshold is sound, and if not, correct emissivity or optics before arming anything.

Does the changing bed depth corrupt the reading?

Only through geometry. Deeper or shallower beds move the viewed surface closer to or farther from the head, which changes the spot diameter, so the check is that the spot stays inside the bed at both extremes of the swing. The radiated signal comes from whatever surface is in view; keep that surface the product or the belt and never the frame or the floor beside the conveyor, and the depth changes cost you nothing.

How close to the belt should the head be mounted?

As close as the mechanics allow while the spot stays fully on the load — halving the distance halves the spot, which is the cheapest way to buy margin. Two limits bind before optics do: the head's ambient rating at that mounting point above a warm, steamy load, and access for cleaning, because dust or film on the sensing window shifts the reading in exactly the way an emissivity error does.

What emissivity should the head be set to?

Start near 0.95 for a rough ore bed — jumbled small faces radiate like most organics and rough minerals — then set it properly by matching a contact probe on the actual load at the same viewing spot. Do not carry a setting across a change of product grade, wetness or surface condition; re-run the probe comparison after any change, because the property belongs to the surface, not to the material name.

Keep reading

  • Troubleshooting

    Why an inductive proximity switch cannot sense motion itself

    An inductive proximity switch cannot sense motion: its output reports only whether a metal target is inside the sensing field. To detect a stopped or very slow mechanism, convert the switch's on/off transitions into events, measure the time between identical edges, and trip a slow-or-stopped fault when that interval exceeds a timeout set from the process. Verify first that the target switches the output decisively at both ends of travel.

    Sensors, encoders and machine vision on the machine

  • How-to

    Wiring a Proximity Switch to Trigger a Robot Gripper and Conveyor

    Wire the sensor's positive and 0 V supply wires to the 24 V DC source and the switched output wire to a robot digital input, taking all three terminal assignments from the sensor datasheet rather than wire color. Confirm the input changes state at Menu > I/O > Digital, then prove the 3-second conveyor run lands the part in the next slot over many cycles, because a timed index only matches the slot pitch while travel stays repeatable.

    Sensors, encoders and machine vision on the machine

  • Explainer

    How a Proximity Switch Detects a Target Bolt on an Axis

    The switch detects a deliberate ferrous target: a bolt protruding from the drive rail that sweeps past the sensing face at about 1/32 to 1/16 inch, a credit card's thickness. Detection turns on that gap falling inside the switch's assured operating distance, 0.81 times Sn against mild steel and less for stainless, brass or aluminium. The controller then reads the input; the program decides whether it means home, a pause, or nothing at all.