Selection guide
Servo drive selection for rigid tapping spindle and feed axes
Short answer
Select the tapping drive pair by whether the interface keeps feed position locked to the spindle's actual angle, not by which protocol is easier to wire. At the spindle's rated 2000 rpm the feed must run 2000 times the thread lead in millimetres per minute, and the 5 Nm spindle rating works out to about 1.05 kW of shaft power. Two independent pulse-train axes need a tension-compensating tap holder or a controller that gears feed to measured spindle angle.

On this page
Take a tapping unit with a spindle servo rated 2000 rpm and 5 Nm, a screw-feed servo rated 2000 rpm and 1.5 Nm with an absolute encoder, and an S7-1214C DC/DC/DC controller. Pick the drives by one criterion: whether the control interface holds feed position to the spindle's actual angle. Rigid tapping means feed travel in millimetres equals spindle revolutions times thread lead, continuously, through entry, cutting and reversal. Two drives that each follow their own pulse train do not hold that relationship. You either gear the feed command to the spindle's measured angle, or you keep independent pulse axes and let a tension-compensating tap holder float the mismatch. The drive family is the easier half: in this drive class the documented motor pairing is the SINAMICS V90 drive with SIMOTICS S-1FL6 motors, taken from the drive's own selection documentation.
The relationship the pair has to hold #
Synchronous tapping — rigid tapping — coordinates spindle rotation and axial feed without relying on a compensating holder to absorb a large mismatch. Thread lead is the axial advance per spindle revolution; for a single-start thread lead equals pitch, and the ISO metric designation carries it: M8 coarse is a 1.25 mm lead.
The defining requirement:
- feed displacement [mm] = spindle revolutions × lead [mm/rev]
- feed speed [mm/min] = spindle speed [rpm] × lead [mm/rev]
At the spindle's rated speed with the 1.25 mm lead, the feed axis must run 2500 mm/min, both directions, with the relationship intact through acceleration and reversal.
The tap binds to actual angle, not commanded angle. Any deviation between the two shows up in the thread as a pitch error:
mismatch [mm] = feed following error [mm] − lead [mm/rev] × spindle following error [rev]
Following error is the difference between commanded and measured position, and it is largest exactly where tapping stresses the pair: during the entry ramp, while the spindle builds speed against the material, and at the bottom of the hole, when both drives step their torque from cutting to withdrawal.
Why two independent pulse axes drift apart #
A pulse-train (PTO) interface sends motion as electrical pulses: the count is distance, the frequency is speed. The controller generates the pulses, the drive's pulse-command input receives them, and the drive closes its position loop on its own motor encoder. Configuring that output stage on the controller side is its own task — see configuring a PLC pulse-output servo axis before PLS2 moves.
Each drive then holds its own command. Nothing in either drive looks at the other axis, so acceleration lag, load-dependent following error and reversal all appear as mismatch between spindle angle and feed position. Work the formula with example values to see the scale: if during reversal the feed lags its command by 0.05 mm while the spindle lags by 0.02 rev, the mismatch is 0.05 − 1.25 × 0.02 = 0.025 mm — about a 2% pitch error on this thread. Those example errors are illustrative, not measured limits. When following error grows past a configured limit the axis trips instead of threading; that fault behavior is covered in troubleshooting a servo axis that faults mid move.
An absolute encoder on the feed axis is worth having, but be clear about what it does: it preserves the machine coordinate across power-off within its counted range. It synchronizes nothing — the feed-to-spindle relationship lives in the command path, not in the feedback memory.
Worked numbers for the example unit #
Shaft power follows P = T × 2π × n / 60, with torque in Nm and speed in rpm. Taking each rating at its simultaneous operating point:
- Spindle: 5 Nm × 2π × 2000 / 60 ≈ 1047 W ≈ 1.05 kW
- Feed screw: 1.5 Nm × 2π × 2000 / 60 ≈ 314 W ≈ 0.31 kW
These are calculated shaft powers for those inputs, not drive input-power ratings and not a complete tapping-duty specification: cutting torque, spindle acceleration and reflected inertia still come from the process and the mechanics.
Feed speed at that same spindle speed: 2000 rpm × 1.25 mm/rev = 2500 mm/min, so the feed motor's speed rating is not the binding limit here — the tap's cutting speed sets how much of the rating you use.
Pulse rate is where pulse-train designs get caught:
pulse frequency [Hz] = motor speed [rpm] × command pulses per motor revolution / 60
The pulses-per-revolution figure is the electronic gearing you configure between controller and drive; how to derive it from the mechanics is the subject of how to calculate step and direction servo pulse scaling. As a worked example, 10,000 command pulses per motor revolution at the spindle's rated speed demands 2000 × 10,000 / 60 ≈ 333 kHz of pulse output per axis, and a cycle that moves both axes together doubles what the controller's output stage must source. Compare that figure against two documented limits — the controller's pulse output maximum and the drive's pulse input maximum, both in the respective manuals — and keep margin. An output-capacity table from one controller line does not transfer to another.
Interface options compared #
| Interface | What it holds | Decisive check | Verdict for rigid tapping |
|---|---|---|---|
| Two pulse-train axes, independent commands | Each axis holds its own command only | Mismatch formula at full depth and reversal, compared with holder float travel | Usable only with a tension-compensating tap holder sized for the computed mismatch |
| Pulse-train feed geared to measured spindle angle | Feed command derived from spindle actual position | Controller supports gearing a pulse axis to a measured value, with fast enough update | Rigid tapping proper; the architecture to build toward |
| Coordinated motion over an industrial network | Controller runs the coordination over one link | The documented motion functions of the exact controller and drive pair | Choose it when the motion package documents axis-to-axis gearing |
| Velocity command, analog or network speed words | Velocity only | None; no position relationship exists in the path | Not a tapping interface on its own |
PROFINET and other industrial networks are wiring convenience until a documented function says otherwise: a drive that accepts network commands does not coordinate with its neighbor unless the controller's motion functions gear them. Check the exact pairing in the maker's function documentation — for this drive family the maker publishes an application example pairing exactly this drive, its 1FL6 motor and an S7-1200-class controller; read which motion functions that example implements before you count on it.
The pulse wiring itself — pulse and sign lines, differential versus single-ended levels, shield termination at the drive input — has a dedicated walkthrough on wiring a pulse-train servo drive to a PLC.
Matching drive and motor to the two axes #
Rated torque is the continuous operating point; peak torque is the transient capability you spend on acceleration and reversal. Size each axis on both: the spindle needs cutting torque plus acceleration of spindle inertia, and the feed needs screw torque from axial force, lead and efficiency plus its own acceleration term. The ratings quoted for the example unit are starting points, not the completed duty calculation.
Then take the pairing from the drive family's selection documentation, not from memory. In this drive class the documented combination is the SINAMICS V90 drive with SIMOTICS S-1FL6 motors; the drive's catalog lists which drive variants pair with which motor sizes, the feedback interface and the required power and encoder cables for each. Stay inside the documented pairing — a motor from a different family of the same maker will not present the encoder interface the drive expects, and the naming differences on the encoder side are exactly what matching encoder signal names between motor and servo drive walks through. Confirm too that the chosen drive variant's pulse-input maximum covers the pulse frequency computed above, with margin.
For the absolute encoder on the feed axis, decide the reference strategy before purchase; the drive manual's commissioning section documents how each variant recovers its machine coordinate after power-off.
The decision, case by case #
If the controller cannot gear an axis to a measured value: do not present two independent pulse axes as rigid tapping. Specify a tension-compensating tap holder, compute the worst-case mismatch with the formula above at full depth and reversal, and confirm the holder's stated float travel exceeds it with margin. Independent axes plus a compensating holder is the conventional way pulse-train machines tap, and it threads acceptably within the tolerance class the part calls for when the computed mismatch is small against the float.
If the controller can gear an axis to a measured value: gear the feed command to the spindle's actual angle. The spindle's position has to reach the controller continuously — a spindle encoder into a high-speed counter input, or the spindle drive's encoder emulation output; sizing a spindle encoder input for servo feed control is its own step. Then the feed axis follows the measured master and the lead relationship survives ramps and reversals with no holder compliance needed to hold pitch. Measure the lead error at the entry ramp on the first cut and confirm it sits inside the thread tolerance; do not assume it.
If coordinated motion over a network is offered: choose it only when the controller's motion package documents axis-to-axis gearing or camming between the two axes on that specific drive family. Networked drives with independent velocity setpoints are no better than two pulse axes.
Drive and motor selection, either way: pick the variant whose approved motor list covers the continuous and peak points computed above — the documented example in this class being the V90 drive with 1FL6 motors — and verify pulse-input bandwidth, feedback interface and cables against the catalog for that exact variant.
One safety note: a tap that binds turns the spindle into a stalled drive and the part into a lever — set the drive's torque-limit function to the tapping duty and run the first parts at reduced speed with the guard closed.
Checks before the first production cut #
- Direction: command each axis alone. Spindle cutting rotation must correspond to feed advance; withdrawal reverses both.
- Scaling: command 10 spindle revolutions with the feed geared, and measure feed travel. With the 1.25 mm lead the dial should read 12.5 mm; any other reading is a scaling error in the electronic gear.
- Reversal: at full depth, record both axes' following error through the reversal and compute the mismatch. Compare against the holder float or the thread tolerance, whichever governs.
- Entry: dwell at the top of the hole until the spindle reaches synchronized speed before the tap bites, and ramp the pair down the same way.
- Faults: confirm the torque limit produces a controlled stop rather than a coast, and that the cycle recovers from a fault predictably.
Questions asked
Does the feed axis need its absolute encoder for rigid tapping?
It is not what makes tapping rigid. The absolute encoder preserves the feed axis's machine coordinate across power-off within its counted range, so a machine with multiturn absolute feedback restarts without a homing run, while a single-turn encoder still needs a reference after its shaft is turned with the drive off. Synchronization lives in the command path. Check that the counted range covers the full screw travel, and take the recovery procedure from the drive manual for the exact encoder variant.
What happens at the bottom of the hole?
Feed and spindle reverse together, and the lead relationship keeps its sign: withdrawal speed equals rotation speed times lead, in the opposite direction. This reversal is where the mismatch peaks, because both drives step their torque from cutting to withdrawal at once and following error jumps. Record the following error of both axes through a reversal at full depth, and size the compensating holder's float travel against the worst mismatch you record, with margin.
How does the pulse frequency scale with tapping speed?
Linearly with spindle speed. The example 10,000 command pulses per motor revolution at the spindle's rated speed needs roughly 333 kHz from the controller; at half that speed the same scaling needs about 167 kHz, and at a quarter speed about 83 kHz. Whatever speed the cycle uses, the controller's pulse output and the drive's pulse input must both carry it with margin, and both limits come from the respective manuals, not from a rule of thumb.
Can one drive follow the other without the controller in the path?
Only if the drive family offers a follower or electronic-gear mode that gears one axis to a master encoder input, which is a function of the specific drive variant, not of the family name. Where that mode exists it removes the controller's update rate from the loop, but the spindle still needs an encoder output the feed drive can read. Check the function list and terminal specification of the exact drive variant before planning around it.