AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Explainer

What a magnetic piston symbol means on a pneumatic cylinder

Pneumatics and hydraulics Published 6 min read By AutomateDirectUSA engineering team

Short answer

On a pneumatic cylinder symbol the magnetic piston is drawn as one thick line between the two thin lines that form the piston, a detail cylinder makers such as Festo document on their symbol sheets inside the ISO 1219 cylinder symbol. On a rack-and-pinion rotary actuator the marking stays on the piston, because the external switch senses the piston magnet, never the pinion or the output shaft.

On this page
  1. What does the magnetic piston symbol look like on a pneumatic cylinder?
  2. Which standard defines the pneumatic cylinder symbol?
  3. How do you draw the magnetic piston into a cylinder symbol?
  4. What changes on a rack and pinion rotary actuator symbol?
  5. Does the piston magnet switch tell you the output shaft position?
  6. When should stroke switches be drawn as separate sensor symbols?
  7. How do you record the marking in your own symbol library?
  8. Questions asked

The symbol is simpler than the search suggests: draw the piston as you always do, with two thin lines, and add one thick line between them. That thick line is the manufacturer-documented marking for a magnetic piston — a piston that carries a magnet so externally mounted switches can detect stroke position. Cylinder makers publish the detail in their catalog symbol sheets, drawn inside the standard cylinder symbol. On a rack-and-pinion rotary actuator the rule does not move: the magnet is in the piston, so the marking goes on the piston lines, and the switches that read it belong on the drawing as separate sensor symbols.

What does the magnetic piston symbol look like on a pneumatic cylinder? #

It is one thick line drawn between the two thin lines that already form the piston in the standard cylinder symbol, the marking manufacturer catalogs use for a piston that carries a magnet for external switch detection.

The two thin lines are the piston of the standard double-acting cylinder symbol; the thick line between them says a permanent magnet travels with that piston. Nothing pneumatic changes: same stroke positions, same port markings, same flow paths, so the marking adds nothing to how the circuit is built or commissioned. What it adds is the sensing path — a reed switch or an electronic sensor clamped to the outside of the barrel actuates as the magnet passes, which is how the assembly reports end of stroke, a mid-stroke station or cycle completion to the controller.

Which standard defines the pneumatic cylinder symbol? #

ISO 1219 is the standard that defines the graphical symbols used for fluid power circuits, and it supplies the base cylinder symbol; the magnetic piston appears in manufacturer catalog documentation as a thick line drawn inside that symbol.

ISO 1219 is what your CAD template and every component catalog lean on for the cylinder body: barrel, rod, ports, and the piston drawn as two thin lines. The magnet detail is documented by the cylinder makers rather than as a standalone standard sheet — manufacturer catalog drawings, Festo's among them, show the magnetic core as that thick line between the piston lines. Decision: draw the base symbol to ISO 1219, add the maker's magnet detail, and note in the legend that the detail follows the manufacturer's catalog convention.

How do you draw the magnetic piston into a cylinder symbol? #

Keep the pneumatic symbol unchanged and add exactly one thick line centered between the piston's two thin lines, then let a legend entry say that this line marks a magnetic piston fitted for external switch detection.

  1. Draw the cylinder to the standard base symbol: barrel, rod, ports, piston as two thin lines.
  2. Add one thick line centered on the piston; that line is the entire marking.
  3. Leave every pneumatic fact untouched: positions, port labels and flow arrows must match the same cylinder without the magnet.
  4. Add the legend entry that names the thick line as the magnetic piston marking, so the next reader knows what it declares.

If positions or ports differ, you have drawn a different cylinder, not a magnetic option of the same one.

What changes on a rack and pinion rotary actuator symbol? #

Nothing about the marking moves: the magnet sits in the piston of a rack-and-pinion rotary actuator, so the marking stays on the piston portion of the symbol, never on the pinion or the output shaft.

A rack-and-pinion rotary actuator is a piston, a rack carried by that piston and a pinion on the output shaft; travel becomes rotation inside the body. Manufacturer sheets show the magnetic detail on the piston symbol, not as a dedicated combined mark for the rotary body. Decision: mark the piston, point it at the same legend entry, and never draw a pinion-side magnet mark for hardware that does not exist.

Does the piston magnet switch tell you the output shaft position? #

No: a magnetically actuated switch reports piston position, and on a rack-and-pinion actuator the output angle follows only through the rack geometry, so the drawing may claim piston detection but not direct shaft feedback.

A switch clamped to the barrel actuates when the piston magnet passes it. Any shaft angle quoted from such a switch is derived from geometry, not measured.

Calculated example, for these inputs: piston travel 31.4 mm, pinion pitch radius 10 mm. Output angle in radians = travel / pitch radius = 31.4 mm / 10 mm = 3.14 rad. Converted to degrees, 3.14 rad × (180° / 3.1416 rad) is about 180°. A switch set at the end of that stroke therefore corresponds to roughly 180° of shaft rotation — a calculated result for these inputs, not a measured one.

The same travel-to-rotation geometry, worked from the motor side of a rack-and-pinion axis, is in calculating pulses per inch for a rack and pinion axis.

Decision: for sequencing and end-of-stroke confirmation, the piston marking plus separate switch symbols is the whole story. The moment the drawing, the controller or the process must treat shaft angle as a measured value, fit a rotary sensor at the output shaft and draw that sensor at the shaft — the piston magnet is not that instrument.

When should stroke switches be drawn as separate sensor symbols? #

Draw each stroke switch as its own sensor symbol beside the cylinder whenever the drawing must show what the controls actually receive, because the thick piston line declares sensing capability, not a wired switch or its set point.

The thick line says a magnet is in the piston; it says nothing about how many switches are fitted, where they sit or what they wire to. Position-switch documentation treats the switches as accessories that confirm position, count cycles or signal completion, and each one is drawn at its own set point on the cylinder. A switch set away from the ends is what makes a mid-stroke hold possible; one such circuit is drawn out in holding a pneumatic cylinder mid-stroke with reed switches.

One safety note: a piston-magnet switch is a position signal for sequencing and confirmation, not a safety function — guarding, interlocks and stored-energy control follow the machine's risk assessment and the applicable machine safety standard.

How do you record the marking in your own symbol library? #

Add one legend entry that names the thick piston line as the manufacturer-documented magnetic piston marking, then apply that same entry to linear cylinders and rack-and-pinion rotary actuators so every drawing in the project reads the same way.

Give the entry plain wording: thick line between the piston lines means magnetic piston, external switch sensing on the barrel, feedback is piston position. Using one entry for linear and rotary bodies keeps a rack-and-pinion drawing from implying shaft feedback it does not have. When the axis needs continuous position instead of discrete stations, the piston magnet cannot supply it, and an analog feedback scheme takes over — path control of a hydraulic cylinder with 4-20 mA feedback works one end to end.

Decisions by case: a standard cylinder with switch detection — the standard base symbol plus the thick piston line. A rack-and-pinion rotary actuator — the same marking on the piston, switches as separate sensor symbols, feedback labeled as piston detection. Shaft angle needed as a measurement — a rotary sensor symbol at the shaft, not the piston magnet.

Questions asked

Can one magnetic piston serve switches at several stroke positions?

Yes. The magnet travels the whole stroke, so switches can be clamped at several stations along the barrel, and each station is drawn as its own sensor symbol at its own set point. The piston carries the marking once; the switches are separate accessories, and how many stations you use is a controls decision, not a property of the magnet.

What physically makes a piston magnetic?

A permanent magnet or magnet assembly is built into the piston itself. The barrel is non-magnetic, so the field passes through the wall and actuates a reed switch or electronic sensor mounted on the outside of the cylinder. The pneumatic circuit is untouched: same ports, same positions, same flow, which is why the marking adds no pneumatics to the drawing.

How is a multi-position cylinder drawn?

Manufacturers document a multi-position cylinder as two separate cylinders joined to act together, and the symbol reflects that composition. Catalog dimensioning takes the retracted rod as the reference position, and each further position must be greater than the sum of the strokes ahead of it. Draw any position switch on the cylinder section it actually senses.

Should the thick line be drawn on a cylinder that has no magnet?

No. The marking exists so the drawing matches the hardware: with no magnet in the piston, the line stays off, and a switch shown on that cylinder would never actuate. A retrofit means ordering the cylinder variant built with the piston magnet, or sensing a different machine feature altogether.

Keep reading

  • Selection guide

    Hydraulic Cylinder Position Sensing in Mud and Sand

    Select the sensing method from the maximum permissible position mismatch, not from the environment alone. At four samples per second, a cylinder moving 100 mm/s travels 25 mm between updates; sensor error and stopping travel add to that. An externally mounted magnetostrictive transducer is the first choice for continuous feedback, a protected cable-extension encoder the second; ultrasonic survives only if the timing arithmetic fits.

    Pneumatics and hydraulics

  • How-to

    Holding a pneumatic cylinder mid-stroke with reed switches

    Energizing both solenoids of a rodded cylinder extends it, because the rod-side area is smaller by the rod area. Drive to the reed switch, drop both outputs so a spring-centered 5-way, 3-position closed-center valve traps the air, and treat reed switches as arrival feedback. For tight tolerances, or wherever losing air could drop the load, use a mechanical stop or a rod lock.

    Pneumatics and hydraulics

  • Explainer

    Why ISA-5.1 has no pneumatic speed controller symbol

    No ISA-5.1 symbol exists for a pneumatic speed controller, and none is missing: ISA-5.1 defines instrument functions, not fluid power hardware. Draw the throttle-and-check unit from ISO 1219 symbols or copy the supplier's catalog symbol for the exact part, define it in the project legend, point the check valve's free-flow arrow for meter-out or meter-in, and mount it at the actuator port.

    Pneumatics and hydraulics