AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Selection guide

What a NEMA 23 stepper router needs from drivers and supply

Motors, gearboxes and drives sizing Published 7 min read By AutomateDirectUSA engineering team

Short answer

Pick each driver by continuous output current that covers the motor's rated phase current, entered in the peak or RMS basis its manual specifies, never by frame size. The winding voltage on the nameplate is not the supply voltage: choose a bus voltage inside every driver's documented input range and size the supply from winding power, about 5 A at 24 V for three such motors.

On this page
  1. The parts and what decides each
  2. The frame size decides nothing electrical
  3. Driver: continuous current and the setting's basis
  4. Controller: one commanded axis per driver
  5. Supply voltage comes from the driver, not the motor nameplate
  6. Worked example: supply for three motors at rated current
  7. Verify the chain before the first cut
  8. The decision for each part
  9. Questions asked

Not just any driver will do, and the numbers already on the motors decide most of the shopping list. Pick each driver for continuous output current that covers the motors' rated phase current, entered in the peak or RMS basis its manual specifies, never by frame size. Treat the 3.78 V nameplate value as winding data, unrelated to the supply: choose a bus voltage inside every driver's documented input range and size the supply current from winding power rather than phase current multiplied by three. The controller needs one independently commanded axis per motor, with outputs that match the driver inputs electrically. The table gives the pick for each part, and the worked example sizes the supply for this exact set of motors.

The parts and what decides each #

The short answer, expanded in the sections below:

Part Decide it by Verify before wiring
Driver Continuous output current covering the rated phase current, set in the peak or RMS basis its manual states Input voltage range, control input type and logic levels, thermal derating notes
Controller One independently commanded axis per motor, coordinated motion for profile cutting, configurable resolution and direction Electrical match to the driver inputs: voltage levels, common reference, pulse timing
Supply DC voltage inside every driver's documented input range, current sized from winding power Regulation and protection for the computed current, wiring sized to carry it

The frame size decides nothing electrical #

NEMA 23 is a mounting convention: it fixes the motor's face dimensions and hole pattern and states nothing about current, voltage, torque or wiring. Two motors sharing that face can differ in rated current by a wide margin, so a driver bought for NEMA 23 is not a selection at all. Start from the motor datasheet and confirm four things: the number of phases, the lead count, the rated current per winding with the basis it is quoted in, and the winding resistance or the voltage-and-current pair that implies it. Six- and eight-lead motors have series and parallel connections with different rated currents, and the connection you choose changes the current you set; why a stepper motor runs hot walks through that winding-connection and phase-current mechanics.

Driver: continuous current and the setting's basis #

Reject any driver whose continuous output current sits below the rated phase current. Some driver datasheets headline a peak figure; a router holds cutting torque for minutes at a stretch, so the continuous rating, under the manual's stated cooling and mounting conditions, is the number that decides. Check the thermal notes for derating with ambient temperature while you are there.

Then set the current in the basis the driver's manual uses. Motor ratings are usually quoted in RMS amps unless the sheet says peak; driver manuals differ, some specifying the setting in peak amps and some in RMS. If the motor's 4.2 A is RMS and the driver's setting is specified in peak amps, enter 4.2 × 1.414, about 5.9 A; if both documents quote the same basis, enter the rating unchanged. Mixing the bases moves the real winding current by a factor of about 1.4, which either overheats the motor or leaves torque on the table.

Controller: one commanded axis per driver #

Plan one driver per motor and one independently commanded axis per motor: three axes for a conventional router. Check the interface on both sides before buying. Most small bipolar drivers take step-and-direction inputs, often through optocouplers with a signal common; the command source must match the drivers' input voltage levels, polarity and pulse timing as both manuals state, and similarly named terminals are not automatically electrically compatible. The controller or command software must also configure step resolution and direction per axis, and it must generate coordinated multi-axis moves if the machine cuts profiles rather than moves one axis at a time.

Many bench routers make a PC at the machine the command source; where that PC shares an enclosure with dust and swarf, the pick at this point is an industrial mini PC rather than an office desktop. Whatever the command source, take the transmission values, screw lead, pulley ratio and microstep setting, from the machine design, so commanded distances land where the software expects.

Supply voltage comes from the driver, not the motor nameplate #

The nameplate voltage is the DC that drives exactly the rated current through a stationary winding: winding resistance times rated current. A chopper drive ignores that relationship on purpose. It switches a much higher bus voltage into the winding and regulates the current by chopping, which is what lets the winding reach rated current quickly and hold torque at speed. The nameplate number is easy to misread; what a stepper motor's voltage rating means covers that reading in detail.

Choose the bus voltage from the driver's manual: inside the documented input range of all three drivers, above any stated minimum and below any stated maximum, respecting the derating notes. Higher bus voltage recharges winding current faster after every chop and buys torque at top speed; it does not change winding heat at a given current setting, which is copper loss, current squared times resistance. For a first build, 24 V DC is the conservative default, a voltage small bipolar drivers commonly accept, but confirm it against your drivers' range before ordering. Stepper motor supply voltage with a chopper drive works through that interaction further.

Worked example: supply for three motors at rated current #

The inputs, each with its source:

  • Rated current: 4.2 A per winding, the nameplate value on these motors.
  • Winding voltage: 3.78 V per winding, the same nameplate.
  • Windings conducting per motor: two, as in any two-phase bipolar connection.
  • Bus voltage: 24 V DC, the default recommended above and an example value to confirm against your driver manual.

The rule: a chopper drive draws from the bus roughly the power the windings dissipate, so bus current equals total winding heat divided by bus voltage. The winding resistance follows from the nameplate pair.

The arithmetic:

  • Winding resistance: 3.78 V ÷ 4.2 A = 0.9 Ω per winding.
  • Copper heat, one motor with both windings at rated current: 2 × (the rated current squared) × 0.9 Ω = 2 × 17.64 × 0.9 ≈ 31.8 W.
  • Three motors: 3 × 31.8 W ≈ 95 W.
  • Bus current: 95 W ÷ 24 V ≈ 4 A.
  • The naive alternative, adding the three phase currents to get 12.6 A at 24 V, would call for a 300 W-class supply, about three times the heat those windings can dissipate.

Result: roughly 4 A at the bus carries all three motors at full rated current, and the estimate holds at speed because the drive regulates winding current, not bus current.

Decision: size the supply at the winding-heat total plus margin for driver switching loss and the power that goes into the cut, and round up to the next common rating. For these inputs that is a 24 V supply in the 5 A, 120 W class; enable the driver's idle-current reduction, the setting that lowers current when an axis is at rest, and parked axes draw well below that.

Verify the chain before the first cut #

Wire with power isolated and keep it isolated while touching motor leads: connecting or disconnecting a motor on an energized driver can destroy its output stage. Pair each coil from the datasheet or the manufacturer's specified continuity test, never from wire colors alone. Set each driver's current from the confirmed rating in the manual's basis, set the resolution, and wire step, direction and enable per both manuals with signal wiring kept apart from motor cables. Check protective earth before first power-up.

Enable one axis at a time at low commanded speed and confirm direction, smooth rotation and repeatable incremental moves. An axis that only buzzes or loses position points to coil pairing, current setting, signal common, pulse timing or mechanical binding; correct one discrepancy at a time and retest. Then run coordinated three-axis motion and watch for driver faults, lost steps or supply sag. If behavior changes only when several axes move together, measure the bus voltage at a driver input under that load. Accept the build when each axis, and one coordinated move, complete the intended travel repeatedly without a missed step, wrong direction or fault.

The decision for each part #

  • Driver: continuous output current that covers the rated phase current, with the setting entered in the manual's stated basis; the difference between a peak and an RMS setting is worth a factor of 1.4.
  • Controller: three independently commanded axes whose outputs match the driver inputs, able to coordinate the axes if the machine cuts profiles.
  • Supply: a DC voltage inside every driver's documented input range, 24 V as the conservative default, sized by winding power, which for this set of motors comes to about 5 A at that voltage.

Questions asked

Does the driver or supply need to be NEMA 23 rated too?

No. NEMA 23 is a mounting convention for the motor face: it fixes the flange dimensions and hole pattern and says nothing about current, voltage, torque or wiring. Drivers and supplies are selected from their own documentation, continuous current, input voltage range and control interface, matched against the motor datasheet, never against the frame size.

Why not size the supply by multiplying the phase current by three?

Winding current and DC bus current are different quantities in a chopper drive. The bus delivers roughly the power the windings dissipate: about 95 W for three such motors, or near 4 A at a 24 V bus, not 12.6 A. Size the supply from winding power plus a margin for driver loss and cutting load.

What current do I set if the driver's setting is in peak amps?

Confirm the basis on the motor datasheet first; motor ratings are usually quoted in RMS unless the sheet says peak. If the motor's 4.2 A is RMS and the driver sets peak amps, enter 4.2 multiplied by 1.414, about 5.9 A. If both documents use the same basis, enter the rating unchanged; mixing the bases moves the real winding current by a factor of about 1.4.

Is it normal for these motors to get hot?

Warm to hot is normal at full current: each motor dissipates roughly 32 W of winding heat, and this frame class runs noticeably hot by design. What is not normal is insulation smell, discoloration or a driver thermal fault. Enable the driver's idle-current-reduction feature so parked axes cool, and lower the setting if the machine holds position for long stretches.

Keep reading

  • Explainer

    When a Stepper Driver Is Rated Below the Motor Current

    Nothing burns: a stepper drive set below the motor's winding rating chops the phase current at its setting, so the motor runs a little cooler with proportionally less torque. The checks that decide the pairing are matching the peak or RMS basis of both current labels, keeping the supply inside the drive's documented voltage range, and sizing the supply for every drive on the machine.

    Motors, gearboxes and drives sizing

  • How-to

    Sizing stepper motors for a DIY aluminum CNC mill

    Size each stepper from the torque its axis needs at screw speed: add cutting thrust, friction and (on Z) gravity, divide by screw lead and efficiency, then pick a motor whose torque-speed curve clears twice that demand at rapid speed. For a 300 × 200 × 150 mm aluminum mill on 5 mm ball screws the worked demand is 0.08–0.14 N·m per axis; set driver current at or below the winding's rated phase current and choose supply voltage within the driver's ceiling.

    Motors, gearboxes and drives sizing

  • How-to

    How to Add Series Resistors to Run a 5 V Stepper at 12 V

    Each energized winding path needs a series resistor that drops the difference between supply and winding rating at rated current — here about 6.9 Ω dissipating 6.9 W, so fit a 20 W part per center tap. One shared resistor in the board's supply lead sees both winding currents and drives a lone conducting path to about 1.7 A, so it is out. A higher supply restores torque at speed but does not silence full-step resonance.

    Motors, gearboxes and drives sizing