Explainer
What Identifies the Bus on a Robot Servo Daisy Chain
Short answer
The 48 V pair and four-pin in/out links prove power distribution and a pass-through topology, not a protocol. The bus is identified only by the motor-mounted module's part number, datasheet and documented pinout: first decide whether each module is a drive or an encoder, then name the interface from its documentation before choosing a controller or applying power.

On this page
- Can the wiring alone tell me which bus the robot uses?
- Is the module on the back of each servo a drive or an encoder?
- Can I assume the bus is EtherCAT?
- How do I identify the interface from documents and markings?
- What if the part number search finds nothing?
- What can a multimeter tell me with the power off?
- Which candidate interface fits the evidence?
- When do I commit to a motion controller?
- Questions asked
A surplus six-axis robot with no controller, a heavier red and black pair daisy-chained through every motor, and a four-pin in plus four-pin out link at each motor-mounted module: that describes power distribution and pass-through wiring, not a protocol. Several unrelated interfaces use exactly that layout. This article separates what the wiring proves from what it does not, gives the document-first procedure that names the interface, one power-off measurement that narrows the candidates, and the decision for each case before money goes into a controller. The motors stay unpowered until the power and signal connections are known.
Can the wiring alone tell me which bus the robot uses? #
No. A 48 V pair daisy-chained through every motor proves only power distribution, and the four-pin in/out links prove only a pass-through wiring topology; several unrelated interfaces share that layout, so the protocol is identified elsewhere.
Split what you have into clues, each with a limit:
- The heavier red and black pair, chained motor to motor: consistent with a shared DC bus feeding electronics at every joint. Confirm its voltage and polarity at the supply end before trusting any number. It cannot tell you the modules are drives, only that something at each node consumes power.
- The four-pin in and out links: consistent with pass-through wiring, where each device repeats the line to the next. They cannot establish a protocol, a pin assignment, a signal voltage, or whether the signals are differential.
- The daisy-chain layout itself: a topology, not a protocol. Ethernet-based fieldbuses, CAN, RS-485, and differential encoder links can all arrive as in/out connectors.
Wire gauge separates power from signal only as a rule of thumb: heavier conductors for power, thinner for data. Current draw and heat belong to power compatibility; take them from labels and datasheets, never from conductor thickness.
Is the module on the back of each servo a drive or an encoder? #
Only the module's part number and its documented pinout decide that. A unit bolted to the motor's rear can be an integrated servo drive, an encoder or resolver, a brake driver, or plain feedback electronics, and the heavier red and black wires only show where the power bus runs.
Physics forces the difference into the wiring, so follow the conductors:
- A drive switches full motor phase current, so heavy phase conductors must run from the module into the motor windings — typically three phases, plus a brake pair where one exists. If nothing heavier than signal wiring leaves the module toward the motor can, the phase path is missing and the module is not the drive.
- A feedback device carries only small signals: a supply and data lines, or sine and cosine pairs. Nothing about it needs heavy conductors, and many joints put the feedback element on the gearbox output rather than behind the motor, so an encoder module can sit anywhere on the joint.
No useful printing is common on surplus hardware and is exactly why the steps below exist. Whether the motors themselves are worth building a system around is a separate question, covered in identifying salvage robot servo motors before drive selection.
Can I assume the bus is EtherCAT? #
Not on this evidence. EtherCAT runs on the ordinary Ethernet physical layer, two differential pairs per port, which a four-pin in and four-pin out link can carry; the same four pins equally fit CAN, RS-485, or differential encoder signals, so the connector cannot separate them.
What the technology actually specifies: EtherCAT is a real-time industrial use of Ethernet that needs no special cables and no crossover, and its simplest structure is exactly the line topology you are looking at. Each device processes the passing frame and repeats it to the next, which is why every slave has an in port and an out port, four wires each.
The connector family is a real clue when the module number is not: in IEC 61076-2-101, the 4-pin D-coded M12 connector is the Ethernet coding for 100 Mbit links, X-code covers gigabit, while A-coded M12 typically carries sensor and power wiring. Photograph the keying; it costs nothing and narrows the field.
The decision: do not buy an EtherCAT master because the topology fits. The bus name must come from documentation, or from measurements that match a documented interface. And if the goal is to program your own motion controller, EtherCAT is the hardest of these candidates to write yourself.
How do I identify the interface from documents and markings? #
The document-first route settles it in four steps: record every marking, trace the wiring with power isolated, find the module's datasheet, and confirm role, supply range, pin functions and bus before anything is powered.
- Photograph each motor, each module on both faces, every connector with its keying, the wire colors, and any supply or cabinet hardware. Record every marking, including cast numbers and board silkscreen if a cover comes off without force.
- With power isolated, map the wiring. Number pins from the connector maker's datasheet, not from wire color. Record which IN pins continue straight through to OUT pins — that is the bus passing by — and which pins stop at the module — that is what the module consumes.
- Search the exact identifiers: module part number, robot model, casting marks, connector number. Search the connector number even when the module number draws a blank.
- From whatever document turns up, confirm four things: the module's role, its allowed supply range, its pin functions, and the named communications interface.
The through-versus-stop map from step 2 is what you hand to anyone helping you, and it tells a technician later which pins are worth measuring.
What if the part number search finds nothing? #
Widen the search before measuring anything: photograph every label, connector key and board marking, note the connector type and wire colors, and search the robot's model, the module's casting marks and the connector maker's number in one query, because a first miss is not proof the module is undocumented.
Surplus robots usually carry a badge, a frame plate, or casting marks that identify the model even when the electronics do not; the model leads to manuals that name the original controller, and the controller names the bus. The connector coding from the previous section is the second handle: an Ethernet-coded connector narrows the field, a sensor-coded one widens it.
If a module might be feedback, the motor-side checks in how to identify geared resolver and encoder feedback on old servos apply directly, because resolver and encoder signals can be recognized from the motor side without the module's paperwork.
When every search fails, the modules are undocumented for practical purposes and the case lands in the last row of the comparison below.
What can a multimeter tell me with the power off? #
With power off, one ohmmeter reading narrows the shortlist: about 60 ohms between the two data wires of a four-pin link means terminated differential pair wiring, the signature of a CAN or RS-485 style bus rather than encoder sine and cosine outputs.
A worked example for that reading: CAN is specified with 120 Ω terminators at the two physical ends of the bus (ISO 11898-2), and a terminated RS-485 link follows the same practice (TIA/EIA-485). With the supply disconnected, the two ends sit in parallel across the pair:
R = (120 Ω × 120 Ω) ÷ (120 Ω + 120 Ω) = 14,400 Ω ÷ 240 Ω = 60 Ω
So a reading near that value, on the same two pins of every in and out connector, is consistent with a terminated differential data pair — a calculated example for two 120 Ω terminators, not a measurement of your robot. An open reading, or one that climbs while capacitors charge, means something else: record it and let the documents decide.
One safety note belongs here: never apply a voltage source to unknown pins to see whether the motor moves. A single wrong voltage destroys an encoder or communications input, a motor that does move will move without warning, and the test still cannot tell a drive from an encoder.
Which candidate interface fits the evidence? #
Three candidates cover almost every case, and the part number decides which row you are in: an integrated servo drive with a documented fieldbus, an encoder or feedback module needing separate drives, or a proprietary link with no public documentation.
| Candidate | Evidence that confirms it | Your decision |
|---|---|---|
| Integrated servo drive with a documented fieldbus | Part number and datasheet name the bus; supply range covers the measured bus voltage; phase conductors leave the module toward the motor | Choose a controller that supports that exact fieldbus, with node capacity for every axis |
| Encoder or feedback module | Part number names a feedback device; only signal-level conductors reach the motor | The robot needs drives: size one from each motor's rated current and match each drive's feedback input to the encoder type |
| Proprietary or undocumented link | A pinout exists but no protocol description; every identifier search fails | Do not buy a controller on a guess: replace the modules with documented drives, or accept that the original controller cannot be reproduced |
When do I commit to a motion controller? #
Commit to a controller only when the bus has a name in the documentation. The controller must support that exact interface, its node discovery and its timing, and a daisy-chain layout matches nothing on its own.
The decision per case:
- Documented drives, named bus: choose a controller that lists that fieldbus and holds enough nodes for all six axes, then commission one axis alone at low speed, with the mechanism free to move safely, before adding the rest.
- Encoders: the project is drives plus a controller. The drive side is decided in what decides old servo motor and new drive compatibility; the controller follows from the drives you pick.
- Undocumented link: writing a controller for an unnamed protocol is not a plan. Replace the modules with documented drives, or start the learning project from a documented interface.
At first power-up, verify the controller detects each device, feedback counts plausibly, and no fault appears at enable. Power present with no communication means rechecking pinout, termination and topology against the documentation, not swapping hardware.
Questions asked
If the pair reads about 60 ohms, how do I tell CAN from RS-485?
The part number decides; the resistor cannot. Both practices terminate with 120 ohms at each end, so the reading only proves a terminated differential pair. A CAN datasheet points to a CAN master running the drive's profile, often CANopen; an RS-485 datasheet usually means serial addressing, commonly Modbus RTU, which most controllers can generate. Measure the pins, then go back to the documents.
Does the shared power pair point more toward drives than encoders?
Yes, as a likelihood, not as proof. A daisy-chained supply feeding every node matches how small integrated servo drives are powered, while encoder supplies normally sit between 5 V and 30 V and would not justify heavy conductors chained through the arm. Treat the pair as a strong hint toward drives and still confirm the role from a module label or datasheet before ordering anything.
If the modules turn out to be encoders, what does the robot need to move again?
One servo drive per axis, sized from each motor's rated current, plus a controller whose outputs match those drives and feedback inputs that accept each encoder's signal type. Incremental feedback adds a homing switch or homing routine at every start-up; absolute feedback removes that step. With six axes you are matching six feedback interfaces, so confirm the drive's encoder input first.
Is writing my own EtherCAT master realistic for a first motion project?
No. The master must service every node within a strict cycle, commonly one millisecond or faster, and keep the distributed clocks aligned before any motion logic runs; that is a real-time software project on its own. For learning motion control by programming the controller, a documented CAN or serial link, or pulse-and-direction drives, delivers the same lessons on hardware you can actually debug.