Troubleshooting
Why a Stepper Axis Oversteps After a Timing Belt Conversion
Short answer
An axis that stops a fixed increment past target on every repeat after a timing belt conversion is losing steps, not coasting. Convert the measured drift into motor full steps: about half a revolution per repeat points at the new belt drive losing synchronism, a few microsteps after each reversal points at direction setup time, and drift only when two axes run together points at the shared 24 VDC supply.

On this page
- Establish the real error before changing a setting
- Worked example: 2 mm of drift on an axis scaled to 20,000 steps per inch
- Mechanical loss of synchronism in the new belt drive
- Direction setup time after every reversal
- The shared 24 VDC supply under two-axis motion
- The signatures and the decision
- Questions asked
Since the mechanics were changed to a timing belt and pulley, the glue-dispensing axis stops a fixed increment past its taught target on every repeated cycle, and the offset grows each time the same program runs. That signature is lost motion, not overshoot: an axis that coasts or bounces stops short or springs back irregularly, while a constant increment per repeat means commanded pulses are not all reaching the shaft. Convert the measured drift into motor full steps, then work the four checks in this order — physical measurement, a shaft-and-pulley witness mark, a reversal-count correlation, and a two-axis supply test — until one signature matches.
Establish the real error before changing a setting #
On an open-loop stepper, the controller's position display follows the pulses it sent, not the turns the shaft made. Lost steps never enter that count, so the display can read a perfect cycle while the machine walks away from its target. The reported machine taught its target at the 100 mark and stopped near the 102 mark; confirm numbers like that on the steel, not on the screen. From a hard datum, run a fixed number of identical repeats and measure the stop position with a dial indicator or a machinist's scale.
Record these observations before touching any setting, because each one decides between the causes below:
- Commanded travel and measured travel for one cycle — separates physical drift from a display or scaling error.
- The signed error after each identical repeat — a constant increment means accumulation; a random one means compliance or slip.
- Whether the increment appears only after a direction change — the reversal signature points at signal timing, not mechanics.
- The motor-shaft-to-pulley mark relationship after a drift run — a rotated relationship means slip at a joint; a fixed one means the rotor itself is losing steps.
- The error with one axis moving versus two axes moving together — error that appears only together points at the shared supply.
Worked example: 2 mm of drift on an axis scaled to 20,000 steps per inch #
Inputs, and where each comes from:
- Measured drift: 2 mm per back-and-forth repeat — the illustrative shift the machine owner used to describe one repeat, taught at the 100 mark and stopping near the 102 mark; the live complaint was about 1 mm of growth per repeat, so substitute your own measurement.
- Scale: 20,000 commanded steps per inch of axis travel — the reported machine's motion setting.
- Microstepping: 16 commanded microsteps per motor full step — the reported machine's drive setting.
- Motor: 200 full steps per revolution — the figure behind the loss signature quoted for this machine, in which a mechanical loss shows up in exact multiples of 4 full steps, 1/50 of a revolution.
- Conversion: 25.4 mm per inch, exact.
Rule in words: turn the linear drift into inches, multiply by the machine's step scale to get commanded microsteps, divide by the microstep count to get full steps, then divide by the motor's full steps per revolution to see how much of a turn the drift represents.
Arithmetic:
- 2 mm ÷ 25.4 mm/in = 0.0787 in
- 0.0787 in × 20,000 steps/in = 1,575 commanded microsteps (1,574.8 unrounded)
- 1,575 ÷ 16 microsteps per full step = 98 full steps
- 98 full steps ÷ 200 full steps per revolution = 0.49 revolution
The drift is about half a motor revolution per repeat. Run the same arithmetic backwards to get the sizes that matter on this axis: one full step moves the load 25.4 mm × 16 ÷ 20,000 = 0.0203 mm, the four-full-step loss grid sits at 0.081 mm, and a two-microstep timing error is 0.0025 mm per reversal.
Decision: a drift of roughly half a revolution per repeat is hundreds of times larger than the per-reversal timing offset, so on this axis the rotor losing synchronism in the new belt drive is the first cause to chase, and the witness-mark test in the next section confirms it in minutes. If your own conversion lands near a whole full-step multiple but only a few micrometres per event, invert the order and start with direction timing.
Mechanical loss of synchronism in the new belt drive #
The machine repeated correctly on its old mechanics, so the belt path is the first suspect. An axis that slides freely by hand proves low friction; it does not prove that the pulley hub, belt teeth and coupling stay registered through powered acceleration and reversal.
Mark the motor shaft and the pulley with a paint pen, run identical repeats until the drift is measurable, and compare the marks. If the marks stay registered while the drift accumulates, the steps are being lost between rotor and load — the motor is stalling momentarily on acceleration and dropping whole full steps. If the mark relationship jumps by whole steps, the slip is at that joint: a loose set screw, a slipping hub or belt teeth skipping under load. On this machine's motor a mechanical loss should land in multiples of 4 full steps — 1/50 of a revolution, about 7.2° — and the computed half-revolution drift satisfies that grid.
Reduce velocity, not only acceleration and jerk. Acceleration was already reduced in the reported case without effect; velocity was never touched. Ramp time is velocity divided by acceleration: with the two numbers equal in inch-based settings the ramp takes 1 s, and most machines reach speed in a fraction of that, which is why acceleration is normally numerically larger — but the two settings carry different dimensions and there is no rule forcing one above the other. Note the trap that a short move finishes before reaching the set maximum velocity, which is why raising velocity can stop changing the actual speed. Jerk's configured dimensions were never pinned down in the report; record them and tune jerk only after the axis repeats cleanly at reduced velocity.
A motor that loses synchronism is stalling briefly on every repeat; the separate question of whether that harms the motor is answered in whether lost steps after a stall damage the motor.
Direction setup time after every reversal #
The second common cause sits in the step and direction signals. If the direction input's setup time is not met before the first pulse after a reversal arrives, that pulse can step one microstep in the wrong direction, leaving a net offset of two microsteps. Every reversal carries a fresh chance of it, so the error accumulates with the reversal count, not the cycle count — and the motion stays smooth throughout, exactly as reported.
That gives a sharp test. Run a program with many short back-and-forth moves, tally the reversals, and log the drift against the tally: the per-event size is microstep-scale, 0.0025 mm per reversal on the example axis, so it hides inside a single cycle and shows only over hundreds of reversals. Then either lengthen the controller's direction-change lead time — the setup window configured in its step-and-direction output settings — or slow the move velocity so the first pulse lands after the window closes. If the accumulation stops, timing was the cause; if it continues unchanged, return to the mechanics and the supply.
Mistimed pulses can corrupt a count by other routes as well; how a timer-driven pulse train delivers the wrong step count covers the count-side failures that have nothing to do with mechanics.
The shared 24 VDC supply under two-axis motion #
Motor noise that rises when two axes move together, while each axis repeats correctly alone, makes the shared supply a legitimate suspect — but noise alone proves nothing. Measure the DC input at the drive while one axis runs, then while two accelerate together, and hold both readings against the drive's documented input range. Probing an energized cabinet is live electrical work: follow the machine's lockout practice and its risk assessment, and lock out before hands touch terminals.
Then check the rating by arithmetic. The reported drive current was set near 3.13 A per axis, and three axes can run together, so simultaneous motion asks for roughly 9.4 A of motor current before the controller's own load. A supply rated below that sags exactly when two axes accelerate together. The reported case never stated the supply's rated output current or the motors' rated current with parallel-connected windings, so read both from the datasheets of the exact parts before concluding; note that two of the reported motors connect their windings in parallel, which draws more current than a series connection would from the same supply. Torque from a chopper drive leans on its supply voltage, and how to pick stepper motor supply voltage with a chopper drive walks through that trade.
The reported Voltage Clamp setting read correct for 24 V operation; leave that setting alone unless your measurement or the drive's documentation shows a mismatch.
The signatures and the decision #
| Measurement result | Cause | Decision |
|---|---|---|
| Drift per repeat near a whole full-step multiple — half a revolution in the example — with marks staying registered | Rotor losing synchronism in the new belt drive | Slow velocity, then re-tension and re-register the belt drive; the drift should stop |
| Pulley or coupling marks rotated by whole steps after a drift run | Slip at that joint | Re-seat and torque the hub and set screws; check belt tooth engagement |
| A few microsteps of drift after each reversal only | Direction setup time too short | Lengthen the direction lead time or slow the moves |
| Error appears only when two axes run together, with the DC input sagging | Shared supply undersized | Rate the supply for the summed set currents plus the controller load |
| Physical stop stable while only the display drifts | Scaling or program behavior | Correct the program or the scale, not the mechanics |
Fix the fault at its cause and re-run the same measurement protocol: same program, same repeat count, physical measurement from the datum. A correction is proven when the physical stop stops walking across repeats and stays put with all required axes moving together. Where the application cannot tolerate any silent step loss at all, closing the loop does it structurally — converting an open-loop stepper to closed-loop control gives the drive its own shaft feedback, so a lost step alarms instead of accumulating.
Questions asked
Why does the DRO look right while the axis is physically off target?
Measure the stop position on the machine itself, with a dial indicator, a scale or a marked datum, and treat the display reading as the commanded position, not the achieved one.
Can a belt conversion cause lost steps even when every fastener is tight?
Yes. A belt and pulley swap changes the reflected inertia and any ratio in the drive train, so the torque needed to accelerate changes with it. Recompute the inertia and torque demand for the new mechanics against your motor's datasheet torque curve; an axis that had margin on the old screw may now need similar torque at higher speed, where a stepper delivers less. Slowing velocity buys margin back.
My drift is random instead of a fixed increment. What does that point to?
An error that changes size between repeats and never lands near a whole full-step multiple is usually compliance or slip rather than lost synchronism: belt teeth jumping under load, a loose pulley hub, coupling backlash or a loose mount. Check belt tension and fastener torque first, then measure repeatability with the load disengaged to isolate which element moves.
Will a larger DC supply fix overstepping by itself?
Only when measurement shows the shared supply sagging below the drive's documented input range while two axes accelerate together. Size the supply so its rated current covers the sum of every axis's set current plus the controller load, then re-measure under the same two-axis motion. If the voltage holds steady through both tests, the supply is not the cause and the mechanics and timing checks decide.