Troubleshooting
Why Ballscrew Coupling Repair Shifts Absolute Encoder Home Position
Short answer
Reassembling a ballscrew coupling at a new clocking angle moves the slide while a motor-side absolute encoder stays healthy, so the machine coordinate is wrong even though the feedback is fine. Prove the coupling cannot slip, compare the displayed coordinate with a documented datum approached from the normal direction, then re-establish the absolute reference there. A linear scale on the slide keeps its datum; do not re-zero it.

On this page
The ballscrew coupling came apart, went back together a few degrees of shaft rotation off, and now the axis sits somewhere the control cannot see: the absolute encoder is healthy and repeatable, but every machine coordinate it feeds is shifted by the reassembly. Where the feedback measures decides the fix. A rotary encoder on the motor, upstream of the coupling, reads only motor shaft rotation, so the slide can move while the encoder value stays put; the stored reference then points at the wrong physical location and must be re-established at a documented datum. A linear scale bolted to the slide measures the slide itself and keeps its datum, so re-zeroing it would create a second error. Work in this order: prove the coupling cannot slip, compare the displayed coordinate with a documented datum, then re-establish the reference there.
Where the feedback measures decides the fix #
An absolute encoder adjustment is a stored mapping: it records which encoder value corresponds to which machine coordinate, and the control uses that mapping to report position without a reference run. On most servo axes the coupling sits between the encoder's measuring point and the slide, so changing the clocking of the coupling moves the slide position that belongs to every encoder value while the encoder itself stays healthy. That is why a coupling repair shows up as a shifted home position instead of an encoder alarm.
Match the axis to one branch before touching reference data:
- Motor-side rotary absolute encoder: the machine coordinate is wrong by the reassembly shift, and the reference must be re-established at the datum. This is the branch the rest of the article follows.
- Direct linear scale on the slide: turning the coupling does not change the scale's reading, so the datum survives; repair the coupling, verify against the datum, and leave the scale reference alone.
- Incremental encoder or feedback type unclear: resolve the configuration from the axis diagnostics and the electrical drawings before changing reference data. An incremental axis runs its configured homing sequence, and an axis that reaches its reference through a sensor follows the practice in homing an absolute encoder axis to a reference sensor.
Prove the coupling cannot slip first #
A reference written into a coupling that still moves will move again, so the mechanics come first, cheapest check first:
- Both coupling halves fully seated, fasteners secured the way the machine builder specifies, keys and locating features in place.
- A paint mark across the joint between the two halves, then jog the axis through a short stroke and back: the mark must hold. Relative movement means slip, and the coupling comes apart again for repair before any referencing.
- The slide free of hard stops and obstructions, because a wrong machine coordinate makes the control's idea of the travel limits unreliable.
Safety note: with the machine coordinate wrong, software travel limits can believe the axis is farther from the mechanical end stop than it is. Jog at reduced feed with the slide path clear and hands out of the envelope.
Backlash that lives in the coupling rather than the screw has its own search order, set out in oldham coupling backlash on a ballscrew axis: find the source first. If the hub surfaces are scored or the coupling has slipped under load more than once, the durable repair is a new flexible shaft coupling matched to both shaft diameters, not a third attempt at the same hub.
Compare the displayed coordinate against a documented datum #
The datum is the machine builder's calibration position: a reference collar, a gauge surface, an indicator over a known pin, with its machine-coordinate value written into the commissioning record. Do not invent a convenient position, because the number entered later must be that documented value.
Approach the datum from the normal production direction at reduced feed, record the displayed machine coordinate, retreat, and re-approach the same way.
Worked example #
Example inputs: a 10 mm lead screw; the coupling reassembled rotated 30 degrees relative to the screw; a datum whose documented machine coordinate is 100.000 mm.
- Expected shift: 30 / 360 × 10 mm = 0.833 mm.
- First approach reads 100.833 mm. Discrepancy = displayed coordinate - datum coordinate = 100.833 mm - 100.000 mm = +0.833 mm, which matches the coupling shift.
- Second approach, same direction, reads 100.833 mm again: the discrepancy repeats, so the encoder-to-mechanics relationship changed once, at reassembly, and the axis is a candidate for referencing.
- A second approach that reads 100.620 mm instead moves the discrepancy by 0.21 mm. Slip or backlash is still active, no reference procedure can fix a coupling that will not hold, and the work goes back to the coupling. If the marks hold and the discrepancy still wanders, the feedback element itself is the suspect, and servo encoder disk slip: fixing the commutation angle after a shift is the next branch to rule out.
Re-establish the absolute reference at the datum #
Run this only once the marks hold and the discrepancy repeats, and record the existing reference data and the measured position first so the previous state can be reviewed.
On a SINUMERIK 840D sl with SINAMICS S120 drive objects, the control documents its referencing functions in the manual chapter named Referencing R1; the exact screens and access levels depend on the machine builder's configuration, so the machine's commissioning instructions travel with that chapter. At the drive level, the S120 absolute encoder adjustment sets the actual position value to the reference point held in parameter p2599 when that value lies inside the encoder's measuring range. Whatever the screens are called, the job is the same: place the axis exactly on the datum by the prescribed measurement method and enter the datum's documented machine coordinate as the reference value.
Do not zero the operator display or edit a work offset to make the axis look correct. Work offsets serve the part program; the machine coordinate carries the travel limits, referencing and safety distances, and only the adjustment restores it.
Verify before production: re-approach the datum from the normal direction and confirm the display equals the datum coordinate, then check a second documented point at the far end of travel if the commissioning record has one. An adjustment that disappears again after every power cycle is a data-retention fault rather than mechanics, and why MC_Home absolute encoder adjustment is lost after power cycle covers that branch.
What each result decides #
| Observed result | Decision |
|---|---|
| Motor-side absolute encoder, marks hold, discrepancy repeats | Re-establish the absolute reference at the documented datum |
| Discrepancy changes between approaches | Slip or backlash is active: repair the mechanics, because referencing only moves the error with it |
| Linear scale on the slide reads the datum correctly | Keep the reference, repair the coupling, do not re-zero the scale |
| Displayed motion direction disagrees with physical motion | Configuration fault: correct it before any reference operation |
| No documented datum value exists | Get the machine builder's commissioning data; an entered guess becomes the new travel-limit error |
So the decision for the coupling-repair case in the opening question: prove the coupling, confirm the repeatable discrepancy against the datum, then re-establish the adjustment at that datum with its own coordinate value. For the linear-scale case, the reference is still true: leave it alone and spend the time on the coupling.
Questions asked
Does a gearbox between the motor and the screw change the shift?
It divides it. A 30 degree re-clocking at a coupling on the motor side of a 5 to 1 gearbox turns the screw only 6 degrees, and 6 / 360 × 10 mm is about 0.17 mm of slide movement. A coupling between the gearbox output and the screw applies the full shift at the screw.
Why approach the datum from the normal direction?
The approach direction decides which side of the axis's reversal the measurement lands on. A servo axis settles against its backlash differently depending on travel direction, so a reading taken from the wrong side can carry the full reversal error. That can make a healthy reference look wrong or a slipping coupling look sound, which is why the comparison only counts when the approach direction matches production.
What changes if I replace the encoder itself?
A new absolute encoder arrives with no stored relationship to the machine, and on a servo motor the motor encoder also defines commutation, which needs the drive vendor's alignment procedure before position feedback means anything. After both steps the same sequence applies: prove the mechanics, place the axis at the documented datum and establish the adjustment there with the datum's coordinate value.
A multi-turn counter alarm appeared during this work. Is that the same fault?
No. A multi-turn counter alarm means the encoder lost its revolution count, typically because backup power to the encoder failed, and the count has to be recovered by the encoder vendor's documented procedure before any referencing is meaningful. A coupling shift leaves the encoder healthy with no alarm; the alarm points at the count, the coupling shift at the mechanics.