Explainer
Adding a Non-Omron Servo Drive to an Omron NJ Machine
Short answer
An Omron NJ can control a non-Omron servo drive only through an interface both devices document at the timing the axis needs: verified EtherCAT with the matching ESI file for coordinated motion, register communication for independent targets, or digital I/O triggering drive-resident moves. An ESI file cannot add EtherCAT hardware a drive lacks, and an Altivar accessory does not fit a Lexium 32.

On this page
- What decides the connection
- An ESI file describes hardware, it cannot add it
- Why an Altivar EtherCAT module is not a Lexium 32 option
- What the Lexium 32 family documents instead
- Who owns the motion profile decides which path fits
- Worked example: follower axis at 500 mm/s beside an existing Omron axis
- The three interfaces that can carry an added axis
- Commissioning the path you picked
- The decision for your machine
- Questions asked
An Omron NJ can control a servo drive from another manufacturer, but only through a command interface both devices document, and only when that interface delivers command updates at the timing the added axis needs. In practice that means one of three paths: verified EtherCAT with the drive's own ESI file for coordinated motion, register communication for independent target positions, or digital I/O triggering moves the drive stores itself. It does not mean installing an ESI file onto a drive that has no EtherCAT port, and it does not mean fitting the EtherCAT module from a different drive family. This article shows how to identify which interface your drive actually has, how the timing requirement decides between the paths, and what commissioning work each path leaves.
What decides the connection #
Two decisions fix the architecture before you touch a laptop to anything. First, which device owns the motion profile: the NJ must generate the trajectory for every axis it coordinates with the existing Omron servos, or the added drive can execute its own profile after receiving a trigger or target. Second, whether the interface physically installed on the drive can carry commands at the update timing that ownership requires.
This is an interface and timing problem, not a motor problem. Motor current, thermal loading and inertia matter when you power the axis for the first time; they cannot make an unsupported protocol supported, and no amount of configuration gives a port the hardware does not have.
An ESI file describes hardware, it cannot add it #
An ESI file — EtherCAT Slave Information file — is the device description the NJ engineering environment reads to configure a slave that is already on the bus. Installing one adds no port, no protocol stack and no process data; it only tells the controller how to talk to EtherCAT hardware that exists. This is why the common advice "just install the ESI file" is only true when onboard EtherCAT has first been confirmed.
A connector shaped like an Ethernet jack is not evidence of a protocol. Modbus TCP and other Ethernet-based protocols use the same RJ45 housing. Confirm the exact drive reference's EtherCAT capability in the manufacturer's own documentation before you plan around it, and read what an EtherCAT label actually tells you about a servo drive before treating a marking on the case as a supported slave profile.
Why an Altivar EtherCAT module is not a Lexium 32 option #
The module that usually gets suggested for this retrofit, the VW3A3601, is documented as an Altivar communication module: a 100 Mbit/s EtherCAT module with two RJ45 connectors, listed for the Altivar drive family. An accessory that belongs to one family does not transfer to another by similarity of name, connector or function.
Schneider Electric's own compatibility documentation states that a Lexium 32M servo drive takes only one communication card, and that the Lexium 32A ships with CANopen as standard. The decision is therefore simple: do not order the Altivar module for a Lexium 32. Read the accessory list published for your exact Lexium 32 reference first, and if a walkthrough of this exact mismatch helps, the page on installing the VW3A3601 EtherCAT module on a Lexium 32M servo drive works through why the two families do not share accessories.
What the Lexium 32 family documents instead #
For the Lexium 32, the documented commissioning route runs through the SoMove software with the Lexium DTM, connected over the drive's CN7 RS485-Modbus port. Communication capability beyond that depends on the variant: the 32M accepts one communication card from its own option list, and the 32A carries CANopen as standard.
Set this against what the NJ side documents. Omron's NJ motion controllers coordinate their axes over the EtherCAT bus, and coordinated motion with the existing servos happens on that network. So the two candidate paths to evaluate are: whether your exact Lexium 32 reference has a documented EtherCAT option of its own, and whether the register interface you can actually build fits the motion requirement. Both answers come from the drive's datasheet and accessory list for that reference — a family name like Lexium 32 alone selects nothing.
Who owns the motion profile decides which path fits #
If the added axis must stay synchronized with the existing Omron servos — a follower, a coordinated pusher, anything where position relationships between axes matter — the NJ owns the trajectory. It must exchange setpoints and feedback with the drive at the controller's motion cycle, predictably, every cycle. A network that is adequate for reading status or occasionally loading a target position is not adequate for that role, because coordination depends on when updates arrive, not whether they arrive eventually. This is the same conclusion other motion platforms document for third-party axes: the engineering page on why one motion controller requires EtherCAT for third-party axes explains the timing argument in detail.
If the axis indexes independently — start, move to a position, stop, signal done — the drive can own the trajectory. The NJ then sends a trigger or a target and the drive executes its locally stored profile. Command latency now affects only when the move starts, not how it runs.
Worked example: follower axis at 500 mm/s beside an existing Omron axis #
The inputs are illustrative example values for one machine, not measured results. A packaging machine's added pusher must follow an existing Omron conveyor axis: master acceleration from standstill to 500 mm/s at 2000 mm/s², a machine requirement set by the product pitch. The verified EtherCAT path updates commands every 2 ms, the controller's motion cycle. The register path, built from a polled exchange, would deliver a new command every 10 ms, the cycle a typical register implementation achieves.
The rule in words: between command updates the drive holds the last setpoint, so a follower commanded in steps changes speed in steps. Each step equals the master's acceleration multiplied by the command interval.
The arithmetic, in that rule's units: over EtherCAT, 2000 mm/s² × 0.002 s = 4 mm/s per step. Over the register path, 2000 mm/s² × 0.01 s = 20 mm/s per step. A single late poll on the register path delays the axis reaction by a further 10 ms at every start and stop.
The result and the decision it leads to: 4 mm/s is 0.8% of the running speed, small enough that the drive's own smoothing absorbs it. 20 mm/s is 4% of running speed, and on this machine it shows up as visible jerk each time the master accelerates. The coordinated follower therefore requires the verified EtherCAT path. The register path fails this machine's timing requirement and remains correct only if the pusher is redefined to index independently, where a 10 ms start delay costs nothing.
The three interfaces that can carry an added axis #
- Verified EtherCAT with the matching ESI file. The drive has EtherCAT, the manufacturer publishes a device description for that reference, and both devices document the motion operating mode the NJ needs. This is the only path that carries controller-owned coordinated motion.
- Register communication for independent targets. The PLC writes target positions or speeds and status, and the drive executes locally. You must implement the handshake yourself: distinguish a command sent from a command accepted and executed, define what happens on communication loss, and sequence acknowledgments and faults.
- Digital I/O triggering drive-resident moves. The drive stores preset positions or sequences; discrete inputs select and start them, discrete outputs report ready, active, complete and fault. Discrete I/O exchanges commands, never a continuous position trajectory, so it fits fixed independent sequences only.
Before the first torque enable on any of these paths, clear the axis travel: with a new command source the first enabled move can run at full speed.
Commissioning the path you picked #
Confirm the drive and motor pairing first: the added motor's current and feedback must match what the drive is configured for, exactly as for any drive-to-motor selection — the four checks in matching a servo drive to a motor apply before anything moves. When the motor itself came from a different maker than the drive, the checks in what decides a third-party servo motor on a new drive are the same ones to run here.
Then, in order: set the drive's command source to the verified interface so no conflicting source silently wins; build the controller side — the ESI-based slave configuration for EtherCAT, or the documented command-and-acknowledge sequence for register or discrete control; and define units, scaling and positive direction against real machine travel, including gearing, before the first production move. Finally, prove the failure behavior deliberately: pull the network or the enable and confirm the axis goes to the state the machine's risk assessment requires, on purpose, not by accident.
The decision for your machine #
- The drive has onboard EtherCAT and a manufacturer-published ESI file for your exact reference: use the verified EtherCAT path, and it can join coordinated motion with the Omron axes.
- The drive has no EtherCAT and no documented EtherCAT option of its own: no ESI file will help. Use register communication or discrete I/O if the axis indexes independently.
- The axis must coordinate with the existing servos and no verified EtherCAT path exists for the drive: change the drive, not the architecture. A supervisory register link pressed into a synchronized-motion role fails on timing, as the worked example shows.
- Any accessory you are about to order: it must appear on the compatibility list for the drive's full reference, suffixes included. A module for another family stays on the shelf.
Questions asked
Where does the ESI file for a non-Omron EtherCAT drive come from?
From the drive manufacturer's own support or download portal, for that exact drive reference and firmware generation. Device description files are version-specific: an ESI file written for a different model or revision can configure wrong process data and object mappings. If the manufacturer publishes no ESI file for your reference, treat that as evidence the reference was not built for an EtherCAT master of this kind, and re-check the hardware before writing any configuration.
Can I fit the VW3A3601 EtherCAT module to a Lexium 32 servo drive?
No. The VW3A3601 is documented as an Altivar-family communication module, and an accessory that belongs to one drive family is not selected for another by similarity. Schneider Electric's compatibility documentation states that a Lexium 32M takes only one communication card and that the Lexium 32A has CANopen as standard. Choose from the accessory list published for your exact Lexium 32 reference, suffixes included.
Can register communication over Modbus TCP run a coordinated axis on an NJ?
Register communication can load target positions, speeds and status words, which fits independent indexing where a few milliseconds of start delay does not matter. Coordinated motion needs setpoints to arrive at the controller's motion cycle, every cycle, because the controller owns the trajectory between updates. A polled register exchange does not guarantee that timing, so it should not be pressed into a synchronized-motion role that a documented EtherCAT axis is meant to hold.
What should I record before ordering anything for this retrofit?
Record the complete drive reference including every suffix, the communication option card already installed, the motor reference and its feedback type, the NJ controller model and the Sysmac Studio version, and the machine's motion requirement in plain terms: coordinated with another axis or independent, travel, speeds, and how often it moves. Family names and port shapes are not enough. Every one of those entries comes from a nameplate, an installed-card inspection or the machine specification, not from memory of the drive family.


