AutomateDirectUSAMotion LibraryShop the parts catalog

Explainer

Are Servo Motor Absolute Encoders Really Battery-Backed

Sensors, encoders and machine vision on the machine Published 6 min read

Short answer

Most servo motors sold as absolute use incremental feedback whose multi-turn count lives in battery-backed memory. The battery feeds a microamp retention circuit, not the operating draw, which is why the hold runs about two years powered down. Change the battery with the control powered so the count survives.

On this page
  1. What 'absolute' covers on these motors
  2. The operating-current figure is not the battery load
  3. The retention budget: a two-year hold against that figure
  4. Changing the battery without losing the count
  5. What actually drops the count
  6. Setting the replacement interval
  7. Questions asked

Most AC servo motors in the Fanuc and Siemens class that are described as having absolute encoders use the battery-backed scheme: a single-turn reading that is truly absolute within one shaft revolution, plus a multi-turn revolution count held in volatile memory that a small battery keeps alive while the machine is off. The battery never carries the roughly 50 mA an encoder draws in normal operation — it feeds a retention circuit in the microamp range — which is why the hold runs about two years of accumulated powered-down time rather than hours. Change the battery with the control powered, and treat time past the hold as borrowed.

What 'absolute' covers on these motors #

Within one shaft turn, the reading comes straight from the encoder's disc or sensing element, so that part of the position is real: the control knows the shaft angle at power-up. What the sensing element cannot know is how many whole turns came before it. On this class of motor, the common arrangement closes that gap with a revolution counter in volatile memory — memory the battery maintains when main power is gone. At the next power-up, the control combines the retained count with the fresh single-turn reading and recovers the full axis position without a homing move.

The position is therefore absolute only as long as the retained count is intact, and two conditions protect it: the battery must keep the memory alive, and the shaft must not be driven farther while unpowered than the backup circuit can track. Feedback types differ, so identify yours before planning anything. Serial-interface encoders behave differently, and battery-less multi-turn absolute types — which sense turns magnetically and are offered on servo and hybrid stepping motor lines — hold position with no battery at all. Match the motor part number against the motor manual's feedback option; identifying geared resolver and encoder feedback on old servos covers the same check for older motors.

The operating-current figure is not the battery load #

The milliamp-level current quoted for a typical rotary encoder is its supply current while the drive or control powers it. At power-off the battery does not feed those electronics at all; it feeds the small retention path that holds the count. Yaskawa's controller documentation gives the sizing rule for that path in plain arithmetic: worst-case battery life equals the battery's amp-hour rating divided by the summed powered-off current of every encoder the battery serves. Where one pack backs several axes, each encoder's powered-off current adds into that sum. While the machine runs, its own supply carries the retention load and the battery is effectively idle — these are primary cells, and nothing in the machine recharges them, so their calendar age counts as much as their powered-down hours.

The retention budget: a two-year hold against that figure #

Inputs, each with its source:

  • Hold target: about two years of powered-down time. A maintenance knowledge base for robot systems publishes approximately two years of controller-off hold as the design figure for encoder backup batteries, and field experience on these servo motors reports at least a couple of years idle.
  • Suspected drain: the typical operating current of a rotary encoder, from the quote above.
  • Method: hold time = battery capacity ÷ powered-off current, the manufacturer rule above.
  • Capacity basis: per 1 Ah of battery capacity, taken as a unit basis; read the real rating from the label of the battery you install.

Rule in words: the charge a hold consumes is current multiplied by time, and the time a battery delivers is its capacity divided by its current.

The arithmetic:

  • Powered-down hours in two years: 2 × 365 × 24 h = 17,520 h.
  • Charge an operating-level load would consume over that hold: 0.050 A × 17,520 h = 876 Ah.
  • Hold that 1 Ah gives at that load: 1 Ah ÷ 0.050 A = 20 h.
  • Retention current implied by the two-year hold, per 1 Ah: 1 Ah ÷ 17,520 h ≈ 0.000057 A, about 57 µA.
  • Ratio of the two currents: 0.050 A ÷ 0.000057 A ≈ 875.

These are calculated figures for these inputs, not measured results. Retention draws under a thousandth of the operating current, and no encoder backup battery is built anywhere near 876 Ah, so the two documented numbers — the operating draw and a two-year hold — can only be true together because the battery feeds a different and far smaller load.

Decision: model the battery as a microamp retention supply, take the amp-hour rating from the label of your specified cell, and plan on roughly two years of accumulated powered-down time from a fresh battery in this class. Past that, expect to re-reference. The control's battery-low alarm, not the calendar, is the primary replacement trigger.

Changing the battery without losing the count #

The retention circuit must stay fed through the swap, and the practical guarantee is main power:

  1. Power the control and amplifiers and let them settle, with all axes stopped. This is work near live electronics — follow the machine manual's battery procedure and its rules for exposed live parts, done only by personnel qualified for live control-cabinet work.
  2. Note each axis's displayed position if you want a before-and-after check.
  3. Fit the specified battery type, observing polarity, and make the swap without delay.
  4. Clear the battery alarm exactly as the manual describes, then confirm that no encoder or reference-position alarm appears.
  5. Write the installation date into the machine log.

If the machine must be fully de-energized for the swap, accept that the count will likely be lost and re-establish the reference position per the machine builder's procedure.

What actually drops the count #

Four patterns account for nearly every lost absolute position on a battery-held axis:

  • The hold ran out: powered-down time past the battery's design life, or an aged cell.
  • The backup path opened: an unplugged battery or a disconnected feedback cable interrupts retention exactly like a dead battery.
  • The shaft moved unpowered: rotating the shaft by hand, or letting a vertical axis drift with its brake released, can move the count past what the backup circuit tracks.
  • The spare was already tired: a replacement that spent years in storage can raise the same alarm within weeks.

A different fault with a similar symptom: position that reads wrong after feedback hardware was replaced, rather than after a power cycle, follows travel error after swapping resolver and encoder causes, not battery ones. If the count is lost repeatedly with a fresh, dated battery installed, stop replacing parts and take the motor part number, amplifier model, and the exact alarm text to the machine builder.

Setting the replacement interval #

Decide by case:

  • One battery per axis, fresh cell: set the calendar inside the documented two-year powered-down hold, with the battery-low alarm as the early trigger. As a rule of thumb, replace at eighteen months to leave margin for shelf age before installation.
  • Several axes on one pack: divide the hold by the number of encoders sharing it, because the hold is capacity over the summed powered-off currents. Six similar axes cut a two-year hold to about four months, calculated from the sum rule with equal draws assumed.
  • Machine to be idle for a long period: replace the battery before storage, or keep the control powered so the supply carries the retention load.
  • Battery of unknown age: replace it and date it. An undated cell has no interval.

Questions asked

How can I tell whether my servo motor's encoder needs a backup battery?

Check three places. Match the motor part number to the manual's feedback option, look for a battery wired into the feedback circuit — it sits either at the amplifier or inline on the encoder cable — and search the control's alarm list for an encoder battery alarm. Batteryless multi-turn absolute encoders, which sense turns magnetically, have none of these and hold position with no battery at all.

Several axes share one backup battery. Does that shorten the hold?

Yes, in proportion. Worst-case life is the battery's amp-hour rating divided by the summed powered-off current of every encoder on that battery, so two similar axes halve a two-year hold to about one year, and six cut it to roughly four months. Find which axes share the pack from the machine's wiring documentation before setting any replacement interval.

Does the machine recharge the encoder battery while it runs?

No. These are primary cells; the control runs the retention circuit from its own supply whenever it is powered, and the battery discharges only during power-off. That is why intermittent duty does not refresh a battery — it still ages on the shelf and still spends its capacity on every powered-down hour, so date each cell at installation and test its voltage against the manual's limit at service intervals.

The shaft was turned while the machine was off. Is the stored position still valid?

Assume it is not. The retained count is only true if the backup circuit saw every revolution, and hand rotation, a belt-driven axis rolled along by its pulley, or a vertical axis drifting with the brake released can move it unseen. Re-reference the axis and verify against a known mark before running anything position-dependent.

Should a battery-backed absolute axis home after every power-up?

No — that is the point of the scheme. With the count intact, the control combines it with the single-turn reading at power-up and the axis is ready without a homing move. If an axis demands homing after every power-up, the retention is failing: suspect the battery, its holder, or the backup wiring before blaming the encoder itself.

Keep reading

  • How-to

    How to Identify Geared Resolver and Encoder Feedback on Old Servos

    Treat the resolver plus its geared 1:4 and 1:80 channels as one integrated coarse-and-fine, multi-turn position package: the resolver reads absolute angle within one shaft revolution, and the geared channels count revolutions above it. Identify each channel by resistance checks, ratio counting and waveform capture before choosing a replacement drive, because the resolver model number alone establishes neither commutation nor multi-turn position recovery.

    Sensors, encoders and machine vision on the machine

  • Selection guide

    Choosing Encoder Resolution to Match a Stepper Step Response

    A 50 ppr encoder read in x4 gives 200 counts/rev — one count per 1.8° full step, so the loop sees only before and after each step and ±1 count is ±1.8°. Size the encoder by counts per full step: 10 counts per step, which is 500 ppr in x4 at 2000 counts/rev and 0.18° per count, is the working minimum to reproduce a stepper's damped step response.

    Sensors, encoders and machine vision on the machine

  • Troubleshooting

    Fix Servo Travel Error After Swapping Resolver and Encoder

    Travel that does not match the position display after a resolver-to-encoder swap is a scaling fault: the drive or the technology axis is still converting counts with the other feedback's increments per revolution. Measure one commanded move and divide actual by displayed travel; a constant ratio equal to the resolution ratio names the encoder data. Fix both layers, re-home, then re-tune.

    Servo and stepper motion