Explainer

Emergency stop on a hydraulic pump or solenoids only

Pneumatics and hydraulics Published 9 min read By AutomateDirectUSA engineering team

Short answer

De-energizing the solenoids and shutting down the pump are different safety functions, not two ways to do the same one. The emergency stop should remove pump power and control stored energy; a guard or light-curtain stop may drop only the valve commands. Venting everything is not a universal answer, because a gravity-loaded cylinder can drop its load.

On this page
  1. What the emergency stop has to do
  2. What stays dangerous after the pump contactor opens
  3. Why the emergency stop should drop the pump
  4. Where a solenoid-only stop belongs
  5. Two circuits, one machine
  6. When venting everything is the hazard
  7. Worked example: opening the nip on a three-roll calendar at e-stop
  8. Deciding the response on your machine
  9. Questions asked

Both answers are right, for two different functions. The emergency stop should remove power from the hydraulic pump and control whatever stored energy the circuit holds, because a stopped pump leaves pressure trapped in hoses, manifolds, accumulators and load-holding valves, and a de-energized solenoid proves only that the coil went dark, not that the spool moved. A stop that drops the solenoid commands and leaves the pump running belongs to a different job: the guard or light-curtain protective stop, where the machine must be back in production within seconds. Which circuit does which job comes out of the machine's risk assessment, not out of habit copied from the machine beside it.

What the emergency stop has to do #

ISO 13850:2015 sets the functional requirements and design principles for the emergency stop function, and it applies whatever energy powers the machine. Read functionally, it asks three things of the e-stop: it acts as a stop command that takes priority over every other function and operating mode, it brings the machine to a safe state, and releasing the actuator must not restart anything — restart takes a deliberate start command from a separate control. What the standard does not do is tell you which contactors to open. That follows from the hazard: identify what sustains the dangerous motion — pump flow, trapped pressure or the load itself — and remove the energy that feeds it.

IEC 60204-1 splits the electrical response into stop category 0, stopping by immediate removal of power, and stop category 1, a controlled stop that keeps power long enough to bring motion down before removing it. A pump circuit is usually category 0: the contactor opens at once and the motor coasts to a standstill. Whatever circuit carries the stop — contactors, relays, and the valve coils if they take part — is designed and verified as a safety function under ISO 13849-1.

What stays dangerous after the pump contactor opens #

Stopping the pump removes the source of new flow. It does not remove the pressure already in the system. Every accumulator stays charged, every cylinder volume stays pressurized, and every load-holding valve keeps holding, because counterbalance valves and pilot-operated check valves respond to pressure signals, not to pump flow. EN ISO 4413, the standard for the safety of hydraulic equipment on machinery, requires every part of the system to withstand the maximum operating pressure of the system or of any component in it, and it treats stored hydraulic energy as a hazard the design has to control — not one that evaporates with the motor.

The load is the second thing that stays dangerous. A vertical cylinder under a gravity load is held by a valve, and the valve holds for exactly as long as its pressure holds. Vent the wrong side and the load moves under its own weight, which is why the reflex answer — dump everything on e-stop — is itself a hazard on some machines, as the calendar example below shows.

The solenoid is the third limit. De-energizing a coil removes the electrical command. It does not prove the spool shifted, does not stop flow past a spool broken or jammed mid-stroke, and does nothing at all about pressure already stored downstream. A coil can be perfect and the valve can still pass flow.

Why the emergency stop should drop the pump #

The pump is the only element in the circuit that can supply energy indefinitely. If a hose lets go, a coupling fails or a spool jams while the pump runs, flow keeps feeding the fault after every e-stop on the machine has been hit. Removing pump power at the e-stop caps what the fault can reach at whatever is already stored, and the stored part is then handled by design rather than by luck.

So the default e-stop response for a hydraulic machine is to open the pump contactor through the safety circuit, paired with a stored-energy sequence chosen actuator by actuator. Where the pump and its motor control center sit in an equipment room far from the machine, add lockable isolation in the supply and return lines near the equipment — high-pressure ball valves with lockout plates are the usual hardware — so service work can be isolated and locked locally. A closed valve is not by itself a safe state: bleed the trapped volume and verify zero pressure at the actuator before breaking a joint.

Where a solenoid-only stop belongs #

There is a second safety function on many machines, and it is not the e-stop. When a guard opens or a light curtain is interrupted for a changeover, the hazard to remove is access to the point of operation, and stopping the pump for the one to two seconds the interruption lasts can be undesirable — heat, long recharge, or a process variable that the disturbance ruins. A separate protective-stop circuit that de-energizes the valve solenoids while the pump keeps turning serves exactly that case.

It is only valid if the machine state it leaves is safe at the point of access: the de-energized valves must positively stop or hold every actuator that can reach the operator, including any gravity-loaded axis. The same decision shows up in pneumatics, in stopping a vertical air cylinder on a light curtain trip, where the load wants to fall and the stop function has to hold it rather than idle it.

A solenoid-only stop also has a hard ceiling: the pump stays energized and every stored pressure stays in place, so it cannot do the e-stop's job and must never be wired as its substitute. On a robotic cell the protective stop has to land on the controller as a safety function the same way — for example through configuring a guard input for a protective stop — rather than as a flag in the application program.

Two circuits, one machine #

The way out of the pump-versus-solenoid argument is to stop treating them as alternatives. One circuit is the emergency stop: it deprives everything of power, pumps included, and carries the stored-energy sequence for each actuator. A second circuit is the protective stop: it de-energizes the solenoid valves whenever a guard opens or the light curtain is interrupted, leaving the pump available for the short interruption. They share the actuators but not the final states, and each is built and verified as its own safety function.

Maintenance isolation is the third arrangement and stays separate from both: lockable valves in supply and return near the machine, a bleed path for every accumulator and trapped volume, and a zero-pressure check at each actuator before work starts. Three functions, three defined safe states — that is the design.

When venting everything is the hazard #

The blanket rule — dump all stored pressure on e-stop — fails wherever pressure or the load itself holds something in a safe place. Vent the load-holding side of a gravity-fed cylinder and the load falls. Release the clamp pressure on a workpiece and the part comes loose. A safe state is a defined machine state, not a zero-energy reading.

A three-roll calendar makes the point sharply. The center roll is fixed and the upper roll is pressed against it hydraulically, with an accumulator feeding the control valves. On e-stop, one such design shuts the pump down and fires a valve that connects the accumulator to the lift side of the upper-roll cylinders, raising the roll to open the nip. That adds stored energy during an emergency stop on purpose, because the safe state is rolls separated, not energy at zero. The price is a raised load afterwards, which then belongs to the maintenance regime: mechanical support or a lockable pin before anyone works under it.

The rule underneath both machines: decide, per actuator, what it should do when the e-stop fires — stop, retract, lift, or stay held — and let that decision, not a blanket vent, select the stored-energy hardware.

Worked example: opening the nip on a three-roll calendar at e-stop #

The numbers below are calculated example inputs for a machine of this kind, chosen so the arithmetic is checkable by hand; take the real dimensions, masses and pressures from your own machine's drawings and installed gauges.

Inputs:

  • Upper roll assembly mass: 1,200 kg, carried by one press cylinder (example input).
  • Press cylinder bore: 100 mm (example input).
  • Pressure trapped at the accumulator and press line when the e-stop fires: 140 bar, equal to 14,000,000 Pa (example input).
  • Gravitational acceleration: 9.81 m/s².

Rule in words: a cylinder lifts a load when pressure acting on its bore area produces more force than the load's weight. Weight is mass times g; bore area is π times diameter squared over four; force from pressure is pressure times area.

Arithmetic:

  • Roll weight: 1,200 kg × 9.81 m/s² = 11,772 N, about 11.8 kN.
  • Bore area: π × (0.100 m)² ÷ 4 = 0.00785 m².
  • Pressure needed just to hold the roll clear: 11,772 N ÷ 0.00785 m² ≈ 1,500,000 Pa, about 15 bar.
  • Force the trapped accumulator can deliver on that bore: 14,000,000 Pa × 0.00785 m² = 109,900 N, about 110 kN, roughly 9.3 times the roll's weight.

Result and decision: with the pump dead, the trapped accumulator pressure is still far above the roughly 15 bar needed to lift the roll, with nine times the force in reserve, so routing it to the lift side opens the nip on stored energy alone. The same figures show why venting is the wrong move here: dump that pressure and the roll closes onto the center roll under its own 11.8 kN — the trapping hazard the e-stop exists to remove. The bore-to-force arithmetic is the same one used when sizing a cylinder bore for a linked lift; only the side of the valve the pressure lands on changes. Once the roll is up, a mechanical support or lockable pin goes in before anyone works beneath it.

Deciding the response on your machine #

  1. Define the functions and their safe states. Emergency stop, guard or light-curtain protective stop and maintenance isolation are three functions; write down the required machine state for each before touching the schematic.
  2. Trace every energy path. Follow the hydraulic schematic from each pump and accumulator through every valve to each actuator. Mark trapped volumes, load-holding valves and any axis a gravity load can move; a machine with no visible accumulator can still trap pressure in an isolated volume between valves.
  3. Give each actuator a final state on e-stop: stop, retract, lift or stay held. That decision selects the hardware — a vent valve, a crossover to the lift side, or nothing beyond the load-holding valve already in place.
  4. Build the circuits separately. The e-stop opens the pump contactor and drives the stored-energy sequence; the protective stop de-energizes solenoids only. Confirm on the electrical drawings which contactor and coil circuits each function actually drops, rather than assuming they match.
  5. Prove it by measurement. Trigger each function in a controlled test with the guarded area clear and every load mechanically supported: measure the stopping time and travel of the hazardous motion, and read the residual pressure at the cylinder ports and the accumulator after the pump contactor opens. Record the numbers; they are the evidence the design works.

The stop response is chosen against the machine's risk assessment and the standards named above; this article is design guidance, not a validation of any particular machine.

Questions asked

Does ISO 13850 force you to shut down the pump on every machine?

No. The standard defines what the emergency stop must achieve: it takes priority over every other function, ends the hazard, and releasing it must not restart anything. It does not name the pump. If the risk assessment shows the pump can keep feeding the hazard, an e-stop that leaves it energized fails the function; if the safe state needs pressure retained, the circuit must hold it deliberately rather than by accident.

Why do some old machines keep the hydraulic pump running through an e-stop?

Some relay-logic machines were built that way decades ago, and later control retrofits have been known to carry the old behavior into the new program, so the pattern survives on floors where half the equipment does it one way and half the other. The original prints are the only record of the intent. Treat a pump that runs through an e-stop as an unverified choice and re-derive the safe state from the risk assessment.

Is closing a manual supply valve enough to make the machine safe?

No. A closed valve stops new flow but leaves every downstream volume charged, does nothing for a gravity load held by a counterbalance valve, and can be on the wrong line to begin with. Isolation for service needs a lockable valve in supply and return, a bleed path for accumulators and trapped volumes, and a zero-pressure check at the actuator before any fitting is broken.

What should the schematic review cover before choosing the stop response?

Find every pressure source and every path to an actuator: pumps, accumulators, load-holding and counterbalance valves, pilot-operated checks that trap volumes, and any axis a gravity load can move. On the electrical side, list exactly which contactor and coil circuits each safety function drops. Then mark a deliberate final state for each actuator: stop, retract, lift, or stay held.

Keep reading

  • Explainer

    Can a PLC Servo Valve Stop a Hydraulic Ram Repeatably

    No — not on a PLC analog output alone. Oil compressibility, load and valve null drift move an open-loop stop, so the loop must close on a ram-mounted transducer, which a Delta Motion note says can position heavy loads to better than 0.0005 in. Decide by measuring today's stopping spread against the part tolerance: if the stop switch meets it, modernize the servo positioner and keep the manual fallback.

    Pneumatics and hydraulics

  • Selection guide

    Controlling Hydraulic Cylinder Position From a 0-10V Analog Input

    No. An analog voltage into a hydraulic valve commands spool position and therefore flow, not cylinder position. Use it as the position reference to a closed-loop motion controller with an in-cylinder displacement transducer, and size the valve near 10 L/min for the 7.8 L/min peak of the 1.5-inch-bore example.

    Pneumatics and hydraulics

  • Troubleshooting

    Diagnosing a Hydraulic Winder That Stalls Under Tension

    When raising the tension command stalls the drive roll of a hydraulic winder, first measure the speed-valve command: if the controller is already at full output, the fault is hydraulic capacity — pump flow, relief setting, filter or internal leakage — not control logic. A top speed of 75 against a documented 150 m/min confirms the drive motor is getting about half its designed flow.

    Pneumatics and hydraulics