Selection guide
Finding a Servo Drive That Accepts a 10V Analog Command
Short answer
The drive's manual must document a bipolar ±10 V command input used by an analog velocity or analog torque mode; a step and direction drive cannot take that signal. Which mode you pick is decided by where the position loop closes: feedback into the controller means velocity or torque mode in the drive. Set full scale so the maximum command equals rated speed or torque and verify the scaling by arithmetic before wiring.
On this page
- Which servo drives accept a bipolar analog command?
- Why can't I connect an analog voltage to a step and direction drive?
- Should the new drive run in velocity mode or torque mode?
- Where should the position loop close: drive or controller?
- What must the drive's manual document before I buy?
- How do I set and verify the analog command scaling?
- Can I convert the analog output to pulses instead of buying an analog drive?
- Which drive matches my motor type and feedback?
- How do I commission the analog axis safely?
- Questions asked
A servo drive will accept a CNC controller's analog output only when its own manual documents a bipolar ±10 V command input feeding an analog velocity or analog torque mode. Drives built for step and direction pulses cannot take that signal, and a general-purpose analog input on an otherwise digital drive does not count. Which analog mode you need is fixed by one fact: which device receives the axis feedback, and therefore closes the position loop. The checks below let you approve or reject a candidate drive from its manual before you spend anything.
Which servo drives accept a bipolar analog command? #
Only drives sold as analog servo drives qualify: their manual lists a bipolar command input of this span feeding an analog velocity or torque mode, and the drive converts the commanded voltage into current commands for the motor.
The bipolar analog command is the classical CNC axis interface: the controller holds a voltage level, the sign carries direction, and the magnitude carries the demand. Marketplace descriptions are routinely vague, because phrases like analog input or multiple control modes tell you nothing. Many drives carry general-purpose analog terminals for a torque clamp or a thermistor without ever using an analog line as the motion command, so those terminals prove nothing.
The mode table in the manufacturer's manual is the deciding document. If the input is not named as the command source in a velocity or torque mode, the drive is out for this controller, no matter what the listing implies.
Why can't I connect an analog voltage to a step and direction drive? #
Because those drives count pulse edges on one terminal and read a logic level on another; a steady analog voltage supplies no edges to count, and no terminal in a step and direction drive interprets a voltage level as speed or torque.
The mismatch runs both ways. A pulse-and-direction drive cannot be driven from an analog-only controller, and an analog-input drive cannot be driven from a controller that only emits pulses. Do not land the analog pair on pulse or direction terminals; that wiring is unsupported and produces no motion.
Low-cost servo kits aimed at stepper-style retrofits are most often pulse-and-direction products, so treat the kit description as a hypothesis until the manual confirms the command interface. The mirror-image problem, a controller velocity output feeding a drive that expects pulses, is covered in driving step and direction inputs from a controller velocity output.
Should the new drive run in velocity mode or torque mode? #
Choose analog velocity mode unless your controller explicitly runs its own velocity loop; then choose analog torque mode, where the drive's torque follows the analog input and speed is governed by the loops above it.
In analog velocity mode the drive turns the motor at a speed proportional to the command and closes its own current and velocity loops. In analog torque mode only the current loop follows the command, and speed is left to the controller. The mode the input works in says nothing by itself about where the loops live; that is a separate wiring question, covered next.
For a retrofit on a controller that closes position only, the standard analog CNC arrangement, buy a drive that documents analog velocity mode and tune the one position loop in the controller. Torque mode buys tighter controller authority when you implement velocity and position loops yourself.
| Drive mode | What the analog line sets | Loops closed inside the drive | Who closes position |
|---|---|---|---|
| Analog velocity | Speed; sign gives direction | Current and velocity | The controller |
| Analog torque | Torque; sign gives direction | Current only | The controller, velocity and position |
| Internal position | Not this line: pulses or a network carry the setpoint | Current, velocity and position | The drive |
Where should the position loop close: drive or controller? #
The position loop belongs to whichever device receives the axis feedback: when the CNC controller's analog card takes encoder feedback and outputs the bipolar command, the controller closes position and the drive must run in velocity or torque mode.
Follow the feedback wires and the answer is decided. If the motor encoder wires only into the drive, the drive owns all three loops and its command is pulses or a network setpoint, and an analog controller cannot close anything around it. If feedback reaches the controller, or a linear scale does, analog is the right interface.
The common retrofit case settles cleanly: a machine keeping its brushed DC axes under one analog controller should get the new axis built the same way, with the controller closed on position and the new drive in analog velocity mode, so every axis tunes under one loop structure.
What must the drive's manual document before I buy? #
Before money changes hands, the manual for the exact hardware revision must show six things: a bipolar command input, the analog mode by name, the scaling parameter, the input wiring, the enable logic, and your motor and feedback in its supported list.
- A command input specified bipolar across the full span, not a unipolar terminal being asked to do bipolar duty.
- A mode named analog velocity, analog speed, analog torque or current mode, with that input named as the command source.
- A scaling parameter that sets full-scale speed or torque at the maximum command, so you can compute rpm or Nm per volt.
- The input circuit: differential pair, input impedance and acceptable wiring, checked against the output drive capability stated in the controller's own manual.
- Enable and fault behavior, including what the drive does at zero command.
- The supported motor type and feedback: brushed DC, brushless with hall commutation, or AC servo with incremental or serial encoder. Resolver-feedback motors need a drive that explicitly lists resolver inputs, which is its own selection problem covered in selecting a replacement servo drive for resolver motors.
How do I set and verify the analog command scaling? #
Set the drive's full-scale speed so +10 V equals the motor's rated maximum speed, then verify one commanded point with arithmetic: at that full scale the drive expects 250 rpm per volt, and a commanded 600 rpm move needs 2.4 V.
Worked example, calculated for these inputs only and not a measured result:
- Motor rated maximum speed, taken from the motor datasheet for this example: 2500 rpm.
- Drive in analog velocity mode, full-scale parameter set to 2500 rpm at the positive maximum command.
- Scaling: 2500 rpm ÷ 10 V = 250 rpm/V.
- Commanded speed at 3.7 V: 3.7 V × 250 rpm/V = 925 rpm; at −3.7 V, −925 rpm.
- Command resolution for a 16-bit controller converter over the 20 V span: 20 V ÷ 65,536 = 0.000305 V per count, which is 0.000305 V × 250 rpm/V ≈ 0.08 rpm per count. Resolution is not the worry.
- Offset check: a 20 mV input offset means 0.020 V × 250 rpm/V = 5 rpm of creep at zero command; trim the offset parameter until zero command holds the shaft still.
Torque mode arithmetic has the same shape: with the motor's rated torque mapped to full command, a 1.9 Nm rating in this example gives 1.9 Nm ÷ 10 V = 0.19 Nm/V, and a 3 V command asks for 0.57 Nm. The controller side of the same conversion chain is explained in how PLC analog input and output modules convert signals, including where resolution is actually lost.
Can I convert the analog output to pulses instead of buying an analog drive? #
Not for an axis whose controller closes the loop: a converter quantizes the controller's continuous output into steps and adds delay inside the loop, so the honest fix is a drive with a native bipolar input or a controller that outputs pulses.
An analog-to-step converter sits between the controller's loop output and the axis, and everything it quantizes and delays degrades the loop the controller is trying to close. As a system decision, replacing the controller to get pulse outputs means re-engineering every axis that currently runs analog, including healthy brushed DC axes you planned to keep. Commit to the analog architecture and buy the analog-input drive; leave the converter idea for open-loop auxiliary motion where nothing closes a loop around the conversion.
Which drive matches my motor type and feedback? #
The drive's power stage must match the motor type: brushed DC motors need a four-quadrant DC servo drive, brushless DC and AC servo motors need a drive that commutates them from hall sensors or an encoder, and AC servo drives are typically sold as matched motor and drive sets.
Brushed motors are the easy retrofit case: any DC servo drive with the right voltage and current and a documented analog command runs them. Confirm the drive's feedback port matches the encoder's supply voltage and logic levels, because older brushed servos often carry higher-voltage encoder electronics than a modern feedback input expects, and the accepted levels are in the drive manual.
Brushless and AC servo motors cannot be separated from commutation: halls, or an encoder the drive can commutate from, plus an initialization routine at power-up. Matched sets avoid that integration risk. If the motor is salvage or surplus, identify it before choosing the drive; identifying salvage robot servo motors before drive selection covers reading the nameplate and feedback first. Check mechanical fit too: shaft diameter, keyway and pilot against your coupling and mount, from the motor drawing.
How do I commission the analog axis safely? #
Bring the axis up decoupled or against its stops with a few hundred millivolts of command: verify zero command holds zero motion, polarity is right in both directions, and the controller's enable chain drops drive enable, all before the load is coupled.
Kill and lock out machine power and confirm the drive's DC bus has discharged before touching command wiring; servo drives hold bus charge after power-off. Then commission in this order:
- With the controller idle and 0 V commanded, enable the drive and confirm the shaft does not move; trim the offset if it creeps.
- Command a small voltage, 0.2 to 0.5 V, one sign then the other, and confirm direction matches the controller's commanded direction. If reversed, swap the command pair at the drive terminals or invert the gain in the controller, never by swapping motor phase wires on a brushless drive.
- Disconnect the feedback and confirm the drive faults rather than running open.
- Couple the load, restore guarding, and tune the controller's position loop from low gains upward until following error settles.
- Record the final scaling, offset and polarity values in the machine file so the next retrofit starts from them.
Questions asked
Can I use a 0 to 10 V controller output with a drive that expects a bipolar input?
Only if the drive documents a unipolar or positive-only command setting. On a bipolar input a positive-only signal gives forward motion and no reverse, because the drive reads negative voltage as the other direction. If the controller is unipolar, pick a drive with a documented unipolar command mode or put a conditioner between them that offsets the unipolar span down to the bipolar one.
What should the drive do when the command is exactly 0 V?
Hold the axis still: in velocity mode the servo lock should keep the shaft from turning, and in torque mode the drive should apply no current beyond what the controller's loops ask for. Creep at a true zero-volt command is an input offset, so trim it, and never leave the command pair floating, because an unterminated input picks up noise the drive will amplify.
Is an analog voltage command less accurate than step and direction?
No. Position accuracy comes from the feedback device and the loops, not from the command wire. A pulse train is itself a sampled approximation of motion, while the analog line carries a continuous demand limited only by the controller's converter, which at 16 bits across the full bipolar span is about 0.3 mV per count. Either interface positions to encoder or scale resolution when the loops are tuned.
Should the analog command be wired single-ended or differential?
Wire it the way the drive's manual shows. Most analog command inputs are a differential pair, and differential over shielded cable rejects the electrical noise a machine's drives and switching supplies create. If the controller has only a single-ended output, tie the drive's negative command terminal to signal ground at the drive end, keep the run short, and route it away from motor power wiring.