AutomateDirectUSAMotion LibraryShop the parts catalog

Troubleshooting

How much stretch sets ballscrew thrust bearing preload?

Linear motion, bearings and guides Published 8 min read

Short answer

The service sheet's 65 µm with a 5 µm tolerance is screw stretch of 0.00256 in, working band 0.00236–0.00276 in. A nut that refuses at 0.0013 in is consuming travel in seating, housing or flange movement, so stop forcing it: verify the indicator reference, the outer-ring interference and the stack dimensions, then retension to the band.

On this page
  1. How much movement should I see when tensioning the ballscrew nut?
  2. Why does the nut get hard to turn at 0.0013 in?
  3. Where should the dial indicator sit to read screw stretch?
  4. How much tension does 65 µm of stretch put in the screw?
  5. What do I check in the thrust bearing housing before retensioning?
  6. What does the dual tensioning method mean?
  7. Can I run the axis at half the stretch spec for now?
  8. Why does the reading change after I lock the nut?
  9. Questions asked

A 65 µm stretch specification is 0.00256 in of screw elongation — 0.00236 to 0.00276 in if the 5 µm tolerance reads as ±5 µm — and a nut that goes hard at 0.0013 in has spent half its travel on something that is not stretch. Tighten no further. Work the checks in order: confirm what the sheet measures, set the indicator across the screw, verify the outer-ring fit and the stack dimensions, then retension into the band. This walkthrough converts the spec, separates stretch from housing movement, and gives the decision for each finding.

How much movement should I see when tensioning the ballscrew nut? #

On a 65 µm sheet, expect 0.00256 in of screw elongation — 0.00236 to 0.00276 in across a ±5 µm tolerance — and treat 0.0013 in as a stop signal, not a setting: it is 33 µm, about half the nominal target and below the band.

The sheet specifies a displacement of the screw, not a torque and not a bearing dimension. Convert it once and write the result down: 25,400 µm makes one inch, so 65 µm ÷ 25,400 = 0.00256 in, and reading "tolerance of 5 µm" as ±5 µm puts the limits at 60 µm and 70 µm. Your 0.0013 in converts back as 0.0013 × 25,400 = 33 µm, which is 27 µm short of the lower limit.

Quantity Micrometers Inches
Nominal specified stretch 65 µm 0.00256 in
Lower limit at ±5 µm 60 µm 0.00236 in
Upper limit at ±5 µm 70 µm 0.00276 in
Movement reached before the stall 33 µm 0.0013 in

The whole acceptance band is 10 µm, or 0.0004 in, so the indicator needs 0.0001 in graduations (2.5 µm) or better; a coarser dial cannot hold the tolerance. Write the quantity, units, tolerance and gauge points on the job sheet before anyone picks up a spanner.

Why does the nut get hard to turn at 0.0013 in? #

Because the travel is going somewhere other than screw stretch — closing assembly gaps, seating bearing rings, shifting a loose flange or housing, or dragging the indicator mount — so more force on the nut is not the next step.

Tightening travel is cheap at first because it closes real gaps: ring faces against spacers, a snap ring settling into its groove, thread clearance in the nut. Only after those close does the screw itself stretch, and stretching a stiff screw takes real force, so the nut should tighten progressively across the full travel. A stall at half the travel with torque rising fast means the load path is blocked or the travel is being measured wrong. Check the cheap things first:

What you see First check What confirms it
Reading repeats differently after re-zero Reset the indicator without touching the nut Mount or contact is moving; the reference is unstable
Indicator moves but the screw end barely does Second indicator on the flange or housing Housing or flange shifting; the first reading is not stretch
Nut torques up almost immediately Back the nut out two turns and spin it by hand Galled or fouled threads, not a preload stop
Nut stalls only under heavy torque Micrometer the stack and the bore fit Clearance or a wrong stack consuming the travel

Do not strike the spanner to chase the reading. Hammering a stalled nut seats whatever is binding by denting it, and brinelled races carry that damage for the rest of their life — while hiding exactly why the travel stopped.

Where should the dial indicator sit to read screw stretch? #

Bridge the gauge from a fixed feature on the screw — the ground end journal or a machined face — to the bearing housing, so the only motion it can report is elongation of the free screw length between the thrust bearing and the tensioning nut.

The builder's measurement diagram governs where the gauge points sit, because elongation is proportional to gauge length: the same tension produces half the movement across half the free length, so a setup measuring a different length than the diagram produces a different number for the same preload. If the sheet did not come with a diagram, ask for it. In the meantime, put the magnetic base on the housing, preload the contact along the screw axis on the center of the end face, and watch the base while tightening — a base that walks reads as travel. An indicator standing on the machine frame includes any housing shift in its number, which is why the second indicator in the table above exists.

How much tension does 65 µm of stretch put in the screw? #

About 22 kN — roughly 5,000 lbf — for a 40 mm steel screw with 30 in between supports, at only about 18 N/mm² of stress, so the specification is a bearing preload, not a material limit, and reaching it should not feel like brute force.

This is a calculated example for these inputs, not a measured result:

  • Cross-section: A = π/4 × (40 mm)² = 1257 mm²
  • Free length: L = 30 in × 25.4 = 762 mm
  • Tension: F = δ × A × E ÷ L = 0.065 mm × 1257 mm² × 206,000 N/mm² ÷ 762 mm = 22,080 N ≈ 22 kN ≈ 5,000 lbf
  • Stress: σ = F ÷ A = 17.6 N/mm²

The modulus is steel's 206,000 N/mm². A heavier screw or a shorter span needs more force for the same stretch, since force scales with area and inversely with length — which is why the displacement, not the effort, is the acceptance number. As a rule of thumb using a 0.2 friction factor, 22 kN at a 40 mm nut is about 175 N·m (130 lbf·ft) of torque, but that estimate moves tens of percent with lubrication and seating. That scatter is why the sheet specifies displacement instead of torque; it is the same physics behind how bolt preload varies with friction and seating.

What do I check in the thrust bearing housing before retensioning? #

Check the outer-ring fit and the stack: the builder's instruction for this repair calls for about 0.0005 in of interference in the outer-race space, with the flange ground to suit, and a micrometer comparison of the old and new bearing stacks before the nut is touched again.

Work this list before the nut turns:

  • Support the head on the machine's prescribed restraint and isolate stored energy per your lockout procedure — a servo holding position is not a mechanical support.
  • Lay the axial stack against the arrangement drawing: bearing orientation, spacers, shoulders and locking hardware, each in its documented place.
  • Micrometer the old and new stacks on a surface plate for overall height and outside diameter. A shorter new stack closes late; a taller one bottoms the flange early.
  • Check the outer rings in the housing bore. Visible clearance — daylight — lets the rings walk, and ring movement is what the indicator has been reading instead of stretch. Grinding the flange to recover the fit is the builder's instruction here, not an improvisation.
  • Take the bore's fit class from the bearing manufacturer's tables for your load condition, not from a similar machine.

Axial location of the outer rings belongs to the housing shoulder and flange; the press fit's job is stopping creep, not carrying thrust. If the stack dimensions or the bore fit are wrong, that is the repair — retensioning over them only repeats the stall. Once the checks pass, the setting follows the same ground as fixing ballscrew thrust bearing axial play and preload: seat, zero, turn to the displacement, lock, re-read.

What does the dual tensioning method mean? #

It is the machine builder's named assembly sequence, and the sheet that names it must also show it — which end is restrained, what is finger-tight versus final, and when displacement is read — so ask for that diagram rather than guessing the steps.

"Dual tensioning method" is not an industry term with one fixed meaning; it is what this builder calls its sequence on this assembly. The companion instruction — put 20 percent load on the head, then finger-tighten — is an energized service step, and a controller load display, a percentage of rated motor torque, and an applied mechanical load are three different quantities. Only the builder's procedure says which one it means; do not approximate it by driving the head against a restraint.

If the written sequence does not arrive in time, this two-stage fallback is sound practice: seat the nut finger-tight under the prescribed head condition and zero the indicator, turn the nut until the indicator shows 65 µm of stretch, lock, then re-read and accept only the post-lock number.

Can I run the axis at half the stretch spec for now? #

Only for slow, light positioning moves — 33 µm of stretch leaves the thrust stack under-preloaded, so expect axial play, and do not cut parts until the fit checks are done and the nut is retensioned into the 60–70 µm band.

Under-preload shows up as play at every direction reversal, and a ring still loose in its bore will creep and fret there under load. Jogging the axis to finish setup or exercise the screw for a day is tolerable; production cutting is not, because the play goes straight into the work. If the axis shows play or noise beyond that, work through diagnosing ball screw backlash, noise and vibration first before adjusting anything else. The decision: availability today, retension before it cuts.

Why does the reading change after I lock the nut? #

Repeat the displacement check after locking without readjusting anything: if the reading drops, the locking step seated another interface, and the fix is to run the documented sequence again, not to add movement on top of an unexplained change.

Locking disturbs the stack — the locknut's own seating, a tab washer being bent over, thread relaxation. Read the indicator after the lock; a number inside 60–70 µm stands. If it dropped, start the sequence over rather than chasing the loss by feel, because adding turns on top of a locked stack is how preloads end up high, and over-preload announces itself as bearing heat and roughness within the first hours of running. If the reading climbs after locking, something seated on its own: stop and find it, because the movement you added was not all stretch.

Questions asked

How do I convert a stretch spec from micrometers to inches?

Divide micrometers by 25.4 to get thousandths of an inch, since 25,400 µm equals one inch. 65 µm ÷ 25.4 = 2.56 thousandths, so 0.00256 in. The same conversion in reverse — multiply inches by 25,400 — turns your indicator reading into micrometers for comparison with the sheet: 0.0013 in × 25,400 = 33 µm.

Is 65 µm a torque setting in disguise?

No. It is a displacement, and the sheet gives it as one because torque scatters badly: the same nut torque produces different tension depending on thread lubrication, coating and how much turning is wasted seating rings. In the worked example the tension needs roughly 175 N·m at the nut by the 0.2 friction rule of thumb, but that figure can move tens of percent either way, so the indicator reading is the only acceptance number.

What does outer-ring clearance in the housing do to the reading?

It converts nut travel into stack shift instead of screw stretch. With clearance behind the outer races, the rings slide axially as you tighten until they stack up against the flange; your indicator reads that motion, the nut then feels solid, and the screw itself carries almost no tension. Loose rings also creep and fret in the bore under load, which is why the builder specifies interference there for this repair.

Should I micrometer the old bearings against the new ones before tensioning?

Yes, before the nut is touched again, on a clean surface plate: overall stack height, each spacer, and the outside diameters. A replacement stack even a few micrometers shorter or taller changes where the flange bottoms and how much travel remains for stretch. Keep the removed bearings until the repair is signed off so the comparison can be repeated if the first retension fails.

What resolution does the indicator need for a ±5 µm tolerance?

At least 0.0001 in per graduation, which is 2.54 µm. The whole acceptance band is 10 µm, or 0.0004 in wide, so a common 0.0005 in dial spans the entire band in one graduation and cannot qualify the setting. A 0.0001 in dial test indicator, or an electronic indicator with finer resolution, resolves the tolerance with margin; verify its calibration before relying on the reading.

Keep reading

  • Troubleshooting

    Fixing Ballscrew Thrust Bearing Axial Play and Preload

    Measure screw end, bearing housing and table movement separately under a reversing axial force. If 0.0002–0.0003 in of play remains between the screw end and the base after the locknut is correctly tightened, the matched back-to-back set has lost its preload: replace it as a set. Shimming the outer rings without the mounting drawing is not a controlled fix.

    Linear motion, bearings and guides

  • Comparison

    Ballscrew vs Zero-Backlash Leadscrew for Aluminum Milling

    Keep the ballscrew machine. A zero-backlash leadscrew is a sliding nut with a spring, and it holds zero backlash only while axial cutting force stays below that spring preload; a ballscrew's preload is geometric and holds under climb-cut load. The 1 in. screws and granite-epoxy base also out-stiffen 0.5 in. screws in cast aluminum, rotary table or not.

    Linear motion, bearings and guides

  • Troubleshooting

    Diagnosing Ball Screw Backlash, Noise and Vibration First

    Most ball screw backlash, noise and vibration is lost lubrication or worn support bearings, not a worn screw. Grease a grease-fitted nut at least monthly, check axial play at the screw end with a dial indicator, and read drive torque to tell friction from play before ordering parts.

    Linear motion, bearings and guides