Selection guide
Hydraulic Power Unit Sizing for a Lathe Chuck Retrofit
Short answer
Size the power unit from the rotating cylinder, not from an assembly number. Two independent demands set it: pressure times effective area gives pull force, and stroke volume over clamp time gives pump flow. Keep the relief below the lowest rated pressure in the circuit, and treat the 2.25-inch bar requirement as a clearance check no pump setting can fix.

On this page
- Read the cylinder and the bore before any pump number
- Pressure sets pull force
- Flow sets clamp time
- Motor power, standby heat and the reservoir
- Worked example: sizing the unit from the cylinder datasheet
- The selection at a glance
- Commission the circuit before the first cut
- The decision, case by case
- Questions asked
Size a hydraulic power unit for a chuck retrofit from the rotating cylinder's datasheet, not from the machine model or an assembly number. Two independent demands set it: pressure times effective piston area gives the pull force, and stroke volume divided by clamp time gives the pump flow. Moving up to 2.25-inch bar on a machine whose factory chuck option stops smaller is a clearance question first: no relief or pump setting widens a bore. The relief setting then has to sit under the lowest pressure rating anywhere in the clamp circuit, and the reservoir is sized by the heat the standby strategy makes, not by flow alone.
Read the cylinder and the bore before any pump number #
The bar must pass through every element of the clamp path: spindle bore, chuck body, jaw opening, drawtube and the rotating cylinder's through-hole. Each maker publishes a maximum bar capacity and the running clearance it wants for its part, and every one of them must clear the stock you cut. The factory option on this machine tops out at 2.06-inch bar where the job needs 2.25-inch, a 0.19-inch nominal deficit. That gap is hardware, not hydraulics. More pressure does not enlarge a bore and more flow does not add clearance, so the cylinder, drawtube and chuck get selected on published bar capacity before the power unit enters the conversation.
The factory power unit for this retrofit circulates under a single assembly number, 30-8070, reportedly filled by more than one supplier, Parker and Rexroth among them. A number that two suppliers can fill identifies a purchased assembly, not a flow, a pressure or a clearance, so it cannot size your unit. Treat it as an identification lead: give the machine tool builder your serial number and ask for the hydraulic schematic and the installation drawing behind that option. Then size against your own cylinder's datasheet, because the retrofit cylinder is not the one the factory package was drawn around.
A rotating cylinder also carries limits that never appear on the power unit: permitted spindle speed, balance, and often a case drain. Run the checks for a rotating hydraulic ram design at spindle speed before anything is bolted behind the spindle.
Pressure sets pull force #
Force out of the cylinder follows the pressure-area product: force in pounds equals pressure in psi times effective area in square inches. For a solid piston, area is 0.7854 times the piston diameter squared; for the hollow piston a bar-fed cylinder needs, subtract the hole, so area is 0.7854 times the piston diameter squared minus the through-hole diameter squared, all in inches. Take the effective area for each direction and the rated pressure from the cylinder datasheet, because the two areas of a double-acting unit rarely match.
This is the same area-to-force arithmetic you run backwards when sizing a bore for a known load, and here it runs backwards again: the chuck maker's grip table gives the cylinder pull your cut needs at top speed, and the relief setting is that pull divided by the effective area. Jaw grip is not cylinder pull. The ratio between them belongs to the chuck, and it falls as spindle speed rises because jaw mass fights the grip, so the pull requirement and the derating curve both come from the chuck datasheet.
The relief setting is also a ceiling: it stays under the lowest pressure rating in the clamp circuit, hose through valve through cylinder to the drawtube connection. Read the working pressure at the cylinder port, because a gauge on the power unit manifold reports the pump, not the actuator.
Flow sets clamp time #
Speed follows volume over time. Compute the stroke volume as effective area times stroke, then the flow in gpm equals 0.260 times that volume divided by the time in seconds; 0.260 converts cubic inches per second to US gallons per minute, from 60 seconds per minute over 231 cubic inches per gallon. Run the division for clamp and unclamp separately and size the pump on the larger quotient, at working pressure, because valve and plumbing losses come out of what reaches the cylinder. The time target is yours: a bar-fed cycle wants the jaws closed before the spindle winds up, so set the number from the cycle and hold the pump to it.
Motor power, standby heat and the reservoir #
Hydraulic horsepower is pressure in psi times flow in gpm divided by 1,714, the constant that turns those units into hp. Divide by the pump's overall efficiency from its curve, where 0.85 is a fair example, and take the next standard motor size up the nameplate ladder.
A clamp pump works seconds per cycle; what it does the rest of the cycle decides your heat. A fixed-delivery pump dead-headed across a relief converts full power to heat every running minute, at 2,544 BTU/hr per hydraulic horsepower. A pressure-compensated pump or an unloading valve drops standby power to leakage, which is why one of the two belongs on a clamp circuit.
Start the reservoir from the rule of thumb of 2.5 to 3 gallons of tank per gpm of pump, then size it to the heat you must reject rather than to the rule: run the heaviest planned shift and hold bulk oil near 120 °F, adding an oil cooler if it settles past about 140 °F. The cylinder's volume swing in the worked example below moves the level by about 11 cubic inches, a fraction of a gallon; the tank is a heat and cleanliness question, not a cylinder-volume question.
Worked example: sizing the unit from the cylinder datasheet #
Every figure here is an example input or a calculated example for those inputs, not a measured result; in a real job each one comes off a datasheet.
Inputs: 2.25-inch bar, so a 2.50-inch cylinder through-hole as the example clearance choice, with the minimum wall between bar and bore taken from the cylinder maker; 5.00-inch piston diameter; 0.75-inch stroke; double-acting; the chuck datasheet calls for 10,000 lbf of pull and lists a grip-to-pull ratio of 0.30 at standstill, both example figures; the cycle wants jaws closed within 0.5 seconds and open within 0.75 seconds.
- Effective clamp area: 0.7854 × (5.00² − 2.50²) = 0.7854 × 18.75 = 14.7 in².
- Relief setting: 10,000 lbf ÷ 14.7 in² = 680 psi. Set the relief at 700 psi to cover line and valve losses; delivered pull is the effective area times that setting, about 10,300 lbf, and standstill grip is 0.30 × 10,300, about 3,100 lbf before the chuck's speed derating.
- Clamp flow: 14.7 in² × 0.75 in = 11.0 in³ of stroke volume; 0.260 × 11.0 ÷ 0.5 = 5.7 gpm. Take the clamp direction as governing here and confirm the unclamp quotient from its own area.
- Motor: 700 × 5.7 ÷ 1,714 = 2.3 hydraulic hp; at 0.85 overall efficiency that is 2.7 hp at the shaft, so the next standard size, a 3 hp motor, carries it.
- Standby heat: a fixed pump dead-headed at the relief setting makes 2.3 × 2,544, about 5,900 BTU/hr, every running minute; with a compensated pump or unloader, standby falls to leakage instead.
- Reservoir: 2.5 to 3 times that 5.7 gpm is 14 to 17 gallons, so a 15-gallon tank starts the design and the shift-length oil temperature decides whether it stands.
Calculated example for these inputs: relief at 700 psi, a pump of at least 5.7 gpm, a 3 hp motor and a 15-gallon reservoir behind a compensated pump or unloader. Change the cylinder, the pull requirement or the cycle time and every one of those numbers moves with it.
The selection at a glance #
The table condenses the decision; the worked example above shows the arithmetic behind the first rows.
| Power unit characteristic | What sets it | Where the number comes from |
|---|---|---|
| Relief setting | Required pull divided by effective area, plus a loss margin | Chuck grip table and cylinder datasheet, verified at the cylinder port |
| Pressure ceiling | The lowest rated component in the clamp circuit | Each datasheet, from hose to drawtube connection |
| Pump flow | The larger of clamp volume over clamp time and unclamp volume over unclamp time | Cylinder areas and stroke, your cycle target |
| Motor power | Hydraulic horsepower divided by pump efficiency, next standard frame up | Pump curve, motor nameplate |
| Reservoir and cooling | Standby heat, checked against shift-length oil temperature | Unload method and duty cycle |
| Clamp proof | Pressure at the cylinder circuit plus measured grip, never pump run | Machine builder's interlock logic, chuck maker's force check method |
Commission the circuit before the first cut #
- Confirm the items the power unit manual names: fluid, cleanliness level, supply wiring, grounding and the documented pump rotation check.
- Set the relief and read the working pressure at a gauge on the cylinder circuit. A panel reading on the power unit can mislead; the classic case is a CNC hydraulic pump showing zero pressure after a shop move, a gauge-and-plumbing problem that never touched the clamp circuit.
- Keep the spindle stopped through first pressurization and the first commanded cycles, and follow the machine's documented service and lockout procedures.
- Cycle clamp and unclamp. Check direction, full travel, both times against target, and freedom from interference through the stroke.
- Prove grip with the chuck maker's method, a strain-gauge force washer in the jaws and a representative workpiece, before cutting loads go on. A pump-running signal proves the motor spins and a manifold gauge proves pressure at the pump; neither proves the part is held.
- Keep the machine's loss-of-clamp response and spindle permissive exactly as the builder's documentation defines them.
The decision, case by case #
- For the example job, the 5.00-inch hollow piston with the 2.50-inch through-hole and 0.75-inch stroke holding the example cut, the unit that comes out of the arithmetic delivers at least 5.7 gpm at 700 psi, driven by a 3 hp motor from a 15-gallon reservoir, with a pressure-compensated pump or unloading valve, the relief under the lowest rated component, and clamp pressure proven at the cylinder port.
- For a different cylinder or a faster cycle, the same two formulas stand; recompute from the new datasheets. The bore gate comes first, then pressure, then flow, then motor and tank.
- For the hunt after the factory assembly number, 30-8070 stays an identification lead: use it to open the parts inquiry with the machine tool builder for your serial number and to pull the hydraulic schematic. The numbers that size your retrofit come from your cylinder and chuck datasheets, not from somebody else's assembly.
Questions asked
Does the factory power unit assembly number tell me what pump and motor are inside?
No. An assembly number identifies a purchased assembly, not a flow, a pressure or a clearance, and one number can cover different internal builds; the factory unit for this retrofit is reported under a single number that more than one supplier filled. Even an original unit's label proves little about the internals, so read the tag data on the unit itself and take sizing numbers from your own cylinder and chuck datasheets.
Which direction sets the pump size, clamp or unclamp?
Whichever demands the larger volume per second. The two effective areas of a double-acting rotating cylinder rarely match, so the stroke volumes differ, and the allowed times can differ too. Compute both quotients and size the pump on the larger one, then confirm at the cylinder during commissioning, because valve and plumbing losses show up in the slower direction first.
What pressure should the relief be set to?
Required pull in pounds divided by effective area in square inches, plus a small margin for line and valve losses, and always under the lowest rated pressure in the circuit; verify with a gauge at the cylinder port. If that calculation lands above the circuit's lowest rating, the effective area is too small for the grip you need, and the fix is a larger-area cylinder, not a higher relief setting.
Is a bigger power unit the safe choice for grip?
No. Grip follows pressure and the chuck's geometry, so extra flow buys speed and standby heat rather than holding force, and extra pressure can push past the weakest component's rating. A pressure-compensated pump about a quarter larger than the calculated flow need is the forgiving choice, with the relief set where the cylinder datasheet supports it.