How-to
Sizing a Hydraulic Cylinder Bore for a Linked Lift
Short answer
Size the bore from the maximum cylinder force the elbow linkage demands anywhere in the travel, not from the 2,000 lb payload. With the modeled 4,000 lbf breakaway demand and 2,175 psi of working pressure, the minimum bore is sqrt(4 x 4,000 / (pi x 2,175)) = 1.53 in, so specify a two-inch bore, good for 6,833 lbf at that pressure. Flow, rod buckling and heat are separate checks.
On this page
Size the bore from the maximum cylinder force the elbow linkage demands anywhere in the travel, not from the 2,000 lb payload. The relation is bore = sqrt(4 x F / (pi x P)): with the modeled 4,000 lbf breakaway demand and 2,175 psi of working pressure, the minimum bore is 1.53 in, so a two-inch bore, good for 6,833 lbf at that pressure, is the cylinder to specify. The payload only fixes the ideal power, 3.64 hp; the linkage fixes the force, the stroke and the cylinder speed. Flow, rod buckling and heat are separate checks with their own numbers, and all of them follow the geometry.
The linkage, not the payload, sets the cylinder force #
In this mechanism the arms are pinned to the top and bottom platforms with a pivot at each elbow, and the cylinder pins to the elbows and pushes them apart to raise the structure. Near the fully lowered position the cylinder pushes almost across the load path, so its force multiplies: the geometry model of this build put the start-of-stroke demand above 4,000 lbf against a 2,000 lb payload, roughly double, falling as the lift rises. Treat that as a modeled floor, not a final design load, because it excluded the moving structure's weight, friction and acceleration, but size on it: breakaway is where an undersized cylinder stalls.
| You know this about the platform | Value | What the cylinder actually needs |
|---|---|---|
| Payload | 2,000 lbf | Force peaking above 4,000 lbf at breakaway (modeled) |
| Travel and time | 8 ft in 8 s | Stroke from the linkage geometry, not from the travel |
| Average platform speed | 1 ft/s | Cylinder speed that varies through the stroke; the worst point sets flow |
| Ideal load power | 3.64 hp | Pressure and flow compared at the same instant |
The formulas, in order #
- Extension force: F = P x A, with piston area A = 0.7854 x D² in in² when the bore D is in inches, P in psi and F in lbf.
- Bore from force: D = sqrt(4 x F / (pi x P)), the same relation inverted.
- Flow: Q = A x v x 60 / 231 in US gpm, with v the cylinder speed in in/s and 231 in³ filling a gallon.
- Hydraulic power: hp = P x Q / 1714.
- Retraction: use the annular area 0.7854 x (D² - d²), with d the rod diameter; retract force and retract flow both follow from that smaller area.
P in these relations is the pressure the unit holds at the pump while the flow is actually being drawn. Comparing a pump's rated pressure and its rated flow separately proves nothing. Checking pressure and flow at the worst point of the move, rather than horsepower against payload, is the same discipline as sizing servo reduction for a belt-driven plasma table axis.
The procedure, step by step #
- Model the linkage from fully lowered to fully raised in small steps; every 10% of travel is enough.
- At each step, record the cylinder pin-to-pin length. Stroke is the longest value minus the shortest.
- At each step, find the motion ratio: how much the platform rises for each increment of cylinder extension. Geometry gives it directly, and so does virtual work, force times distance in equal to force times distance out.
- Convert the load to cylinder force at each step: payload plus moving structure weight, plus friction and inertia for a fast cycle. The worst ratio sets the design force, which for this build sits at the start of extension.
- Fix the design pressure: what the unit holds at relief while flowing, not its standby pressure. Here, 2,175 psi.
- Compute minimum area as design force divided by pressure, then minimum bore from that area, and buy the next standard bore above it.
- Verify the real bore: 0.7854 x D² x P must meet the design force with margin for everything the model left out. Thirty to seventy percent above the modeled peak is a workable band; that is a rule of thumb, not a rating.
- At the position where the cylinder moves fastest relative to the platform's motion, compute flow and hydraulic power, and compare both against the pump at the same time.
- Close out rod buckling, the return stroke and heat rejection before ordering.
Sizing the bore for a 2,000 lb elbow-linkage lift at 2,175 psi #
Inputs, each with its origin:
- Payload: 2,000 lbf, the design load.
- Travel and time: 8 ft in 8 s, so average platform speed = 8 ft / 8 s = 1 ft/s (calculated).
- Peak cylinder force: 4,000 lbf, the floor from the linkage geometry model at breakaway (modeled, excluding structure weight, friction and acceleration).
- Design pressure: 2,175 psi, the working pressure quoted for the available unit in the sizing exchange.
- Power unit on hand: 15 hp with a 30 gal reservoir.
- Candidate bores: 1.5 in and 2 in, the sizes proposed in that exchange.
The rule in words: piston area is force divided by pressure; bore is the square root of four times that area divided by pi. Flow is area times cylinder speed, converted to gallons per minute; hydraulic power is pressure times flow divided by 1714.
The arithmetic:
- Minimum area: 4,000 lbf / 2,175 psi = 1.84 in².
- Minimum bore: sqrt(4 x 1.84 / pi) = sqrt(7.36 / 3.1416) = sqrt(2.34) = 1.53 in.
- Check 1.5 in: A = 0.7854 x 1.5² = 1.77 in², so F = 1.77 x 2,175 = 3,843 lbf, which is 157 lbf short of the modeled floor before any unmodeled loads.
- Check the larger candidate: A = 0.7854 x 2² = 3.14 in², so F = 3.14 x 2,175 = 6,833 lbf, which is 71% above the floor.
- Cylinder speed at the same critical position, lossless check: virtual work sets cylinder speed to platform speed times the inverse force ratio, so v = 1 ft/s x (2,000 / 4,000) = 0.5 ft/s = 6 in/s.
- Flow there: Q = 3.14 in² x 6 in/s x 60 / 231 = 4.9 gpm.
- Pressure the load needs through the larger bore: 4,000 / 3.14 = 1,273 psi, so hydraulic power = 1,273 x 4.9 / 1714 = 3.64 hp, matching the ideal load power. The check closes.
- Unit ceiling: 15 hp at 2,175 psi supplies Q = 15 x 1714 / 2,175 = 11.8 gpm, theoretical; the 3.14 in² piston passes 0.816 gpm per in/s, so full pressure caps cylinder speed near 14 in/s.
Result: minimum bore 1.53 in; selected bore is the larger candidate listed above.
The decision: any bore that cannot deliver the modeled peak force plus margin at your pressure is out, so the 1.5 in is out and the selected bore is in. If the bore you want fails, move the cylinder pins or the elbow geometry to soften the breakaway disadvantage; raising pressure to rescue a small bore is the wrong lever. The 15 hp unit passes the critical position with room, 4.9 gpm at 1,273 psi against an 11.8 gpm capability, and only runs out above roughly 14 in/s of cylinder speed at full pressure. Every number above is a calculated example for these inputs, not a measured result.
Rod buckling and the return stroke #
The stroke is the change in pin-center distance, measured in the model; do not infer it from the 8 ft platform travel. Whatever it turns out to be, the push-loaded rod is a column: its allowable compressive load depends on the unsupported length at full extension, the rod diameter, the end conditions of both mounts (treat clevis-to-clevis as pinned at both ends) and the material. Take the limit from the cylinder manufacturer's buckling data for that stroke and family, and never from burst pressure. The 1.5 in rod proposed alongside the small bore cannot be accepted or rejected without the stroke and the mounts; that is exactly the data the manufacturer will ask for.
If the cylinder must pull the lift down rather than let it descend by gravity, retraction force comes from the annular area, 0.7854 x (D² - d²). Thickening the rod to survive buckling shrinks that annulus, which can force the bore up, which slows extension for the same pump flow. Decide how the load comes down before fixing bore and rod together.
Heat, tank volume and duty cycle #
Useful work per lift is 2,000 lbf x 8 ft = 16,000 ft-lbf. At three lifts a minute the useful average power is 3 x 16,000 / 33,000 = 1.45 hp, and everything the 15 hp unit draws above that ends up heating the oil. The 30 gal tank holds temperature for intermittent duty at about three lifts a minute; for this build the working limit that came out of review was roughly half an hour of continuous cycling, beyond which a cooler must be sized. Treat that as a design warning for these inputs, not a verified thermal rating: fix the duty cycle and the oil temperature limit, then compute the heat rejection.
Keep the load controlled #
A lifting machine with people near it carries obligations on the hydraulic side, and ISO 4413 governs them: the design must stop the load descending when a hose, fitting or valve fails, met in practice with pilot-to-open load-holding valves mounted at the cylinder rather than a closed center alone, and lowering must be metered, stable and protected against overpressure. Build those into the circuit before commissioning, then prove them by test with the real load through the full travel, watching pressure and cycle time, under the machine's risk assessment.
Questions asked
Would a cylinder sized on the 2,000 lb payload alone work?
No. A direct vertical lift of 2,000 lbf at 2,175 psi needs only 0.92 square inches of piston area, about a 1.08 in bore, but the elbow linkage demands over 4,000 lbf at the start of the stroke. Size from the modeled linkage peak, which points to a two-inch bore, or the cylinder will stall as the lift breaks away.
Can the 15 hp unit raise 2,000 lb through 8 ft in 8 seconds?
Yes, on paper. Ideal load power is 3.64 hp, and at the worst linkage position the selected bore (3.14 in² of piston area) needs about 4.9 gpm at 1,273 psi, which is again 3.64 hp. The 15 hp unit can theoretically supply 11.8 gpm at 2,175 psi, so the margin is real but theoretical; confirm the pump's actual flow at pressure before committing.
How do I find the cylinder stroke for an 8 ft platform travel?
Measure it in the linkage model. Stroke is the difference in the distance between the cylinder's pin centers, fully retracted and fully extended. For an elbow linkage it is usually much shorter than the platform travel, and it sets the rod buckling check, the flow per second and the tank volume, so extract it before ordering anything.
Is a 1.5 in diameter rod adequate for this lift?
That cannot be accepted or rejected from the bore alone. Rod buckling depends on the unsupported rod length at full extension, the end conditions of both mounts, the rod material and the peak compressive force, here over 4,000 lbf. Take the rod size from the cylinder manufacturer's buckling data for the exact stroke, and favor the shortest unsupported length you can package.
Why choose hydraulics instead of pneumatics for this lift?
Force and control. Air is springy: a 2,000 lb load riding on an air column has a low natural frequency, so a fast 8 ft move would oscillate and be hard to stop anywhere but a hard stop. Hydraulic oil is stiff, holds position under load and gives smooth, metered descent, which is what a linked lift of this size needs.