AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Comparison

Low-speed spindle at 5 to 10 rpm: VFD or servo with gearbox

Motors, gearboxes and drives sizing Published 11 min read By AutomateDirectUSA engineering team

Short answer

Continuous 5-10 rpm spindle rotation with proportional following is VFD work: gearbox, spindle encoder and electronic gearing in the motion controller. Commanded spindle angles and coordinated position moves are servo work. Size the drivetrain from spindle torque, not the motor kW figure: 100 Nm at 5 rpm is about 52 W, and a 12 Nm servo behind a 10:1 gearbox gives a calculated 120 Nm before losses.

On this page
  1. VFD or servo for a spindle that runs at 5 to 10 rpm?
  2. Does an encoder on a VFD make it a position drive?
  3. How much motor does 100 Nm at spindle speed actually take?
  4. What gearbox ratio does a 12 Nm servo need to reach 100 Nm?
  5. What ratio does a geared induction motor need instead?
  6. Will the motor overheat on continuous duty at low speed?
  7. Which drivetrain do I order for each duty?
  8. Questions asked

Match the drivetrain to the motion the controller actually commands, not to the habit of calling every spindle an axis. Continuous rotation in the 5 to 10 rpm window, with the traverse following measured spindle turns, is VFD work: a three-phase induction motor, a gearbox, a spindle encoder and electronic gearing in the motion controller. Commanded spindle angles, holding against load and coordinated rotary-linear moves are servo work, because they need a drive that closes a position loop. Size the drivetrain from spindle torque, not from the kilowatt plate: a 100 Nm continuous load at 5 rpm takes about 52 W at the spindle, while 2.2 kW delivered there would mean roughly 4,200 Nm. The sections below give the decision for each duty, the arithmetic behind it, and the thermal checks that keep a continuously running low-speed spindle out of trouble.

VFD or servo for a spindle that runs at 5 to 10 rpm? #

A VFD with a gearbox is the right machine for continuous rotation with proportional following, and a servo is the right machine the moment the controller commands a spindle angle and must hold it, because position control is a different control mode rather than a tighter speed loop.

The two requirements sound similar and size completely differently. A VFD regulates speed: it takes a speed reference and holds output frequency against load. Electronic gearing in the motion controller turns that into a coordinated machine: the spindle encoder reports actual spindle rotation, and the controller commands the traverse in proportion to it, so material winds evenly even while the spindle slows over the domed ends. A servo instead closes a position loop on the spindle itself: the controller commands an angle, the drive runs until measured position equals commanded position, and the axis holds there.

Motion required at the spindle Architecture that serves it Acceptance check
Continuous rotation while the traverse follows measured spindle turns Induction motor, VFD, gearbox, spindle encoder, motion controller with electronic gearing Traverse travel per spindle revolution stays correct through the whole speed profile, including the slower sweep over the ends
Move to a commanded angle and hold against load Servo motor and drive sized on continuous torque, with reduction The settled spindle stays within the required angular error under load
Coordinated rotary and linear positioning moves Servo spindle axis inside a coordinated motion controller Both axes hold the commanded path within their following-error limits

Does an encoder on a VFD make it a position drive? #

No — a spindle encoder on a VFD-fed motor gives the controller a measurement of spindle rotation, which is exactly what electronic gearing needs, but the drive still only executes speed commands, and speed regulation, however tight, is not the command response a position loop closes through.

An encoder measures; the drive mode acts. A speed-mode VFD never receives an angle to drive toward, so measurement resolution cannot create commanded position inside it. A high-resolution encoder is still worth fitting: it improves the gearing resolution the controller sees. What it cannot do is change the drive's control mode.

One reported lathe retrofit makes the ceiling concrete. The spindle ran from a VFD under an external motion controller and held every set speed from about 5 to 5,500 rpm without visible drift, yet no gain setting produced a usable positioning move; raise any gain above zero and the axis ran away. Take that as one reported symptom, not an accuracy specification for drives in general — it shows the gap between holding a speed and following a position command.

How much loop gain an axis tolerates before it oscillates is a property of that axis and its drive, which is why notes on axis loop tuning report workable gain factors anywhere from 0.6 to 3.7 between machines. One machine's tuning numbers do not transfer.

An induction motor can serve a positioning application when the whole chain is built for it — a drive running the motor in closed-loop torque or position mode with suitable feedback. An encoder added to a speed-mode VFD is not that chain, and no amount of encoder resolution changes the drive's mode.

How much motor does 100 Nm at spindle speed actually take? #

For a 100 Nm continuous spindle load, the mechanical power is 52 W at 5 rpm and 105 W at 10 rpm, while a 2.2 kW rating delivered at 5 rpm implies about 4,200 Nm at the spindle — a different gearbox, shaft and coupling duty.

Shaft power is P (W) = T (Nm) × 2π × n (rpm) / 60. At the continuous spindle load, n = 5 rpm gives 100 × 31.42 / 60 = 52.4 W and n = 10 rpm gives 104.7 W. Run the same equation backwards, T (Nm) = P (W) × 60 / (2π × n), and 2,200 W delivered at 5 rpm means 4,202 Nm at the spindle; at 10 rpm, 2,101 Nm. Those two lines are the whole argument: at this speed, torque is the sizing quantity and power follows from it.

Before keeping a 2.2 kW plate as a requirement, establish where it came from: a process calculation at some other speed, an existing motor's rating, or an allowance for a second, faster duty this spindle also runs. If winding is the only continuous duty, the steady-state need at the motor shaft works out under 1 Nm once the reduction and a realistic gearbox efficiency are applied (the arithmetic is in the two sections below), and the frame is then chosen on acceleration torque, duty cycle and gearbox capacity rather than on the steady figure.

Size the load properly: calculate process torque over the whole cycle, including the slower passes over the domed ends; add friction and acceleration using the real reflected inertia; separate continuous torque from short-duration peaks and record how long each peak lasts; and decide whether the axis must hold torque while stationary or can be back-driven. Those inputs pick the motor. The kilowatt plate does not.

What gearbox ratio does a 12 Nm servo need to reach 100 Nm? #

A 12 Nm servo motor behind a 10:1 gearbox delivers a calculated 120 Nm at the spindle before efficiency, and 15:1 delivers 180 Nm, so a 100 Nm continuous requirement is met by the 10:1 ratio — provided the 12 Nm figure is continuous torque, not peak.

Ideal spindle torque: T at the spindle = motor torque × ratio × gearbox efficiency. With a ratio of 10, 12 × 10 = 120 Nm before losses; at a typical multi-stage gearbox efficiency of 0.9 — a rule-of-thumb figure, so take the datasheet value for the exact unit — about 108 Nm, still above the requirement. With a ratio of 15, 180 Nm before losses, about 162 Nm at the same assumption, which buys margin for load growth.

Motor speed = spindle speed × ratio. At 10 rpm spindle speed, a ratio of 10 needs 100 rpm at the motor and a ratio of 15 needs 150 rpm; halve both for the low end of the range. Every servo holds continuous torque across that band, but confirm it on the specific torque-speed curve, and confirm the motor rating there is the continuous figure, because peak ratings are short-time figures governed by the manufacturer's curve.

The gearbox decides winding registration as much as the ratio does: check its continuous output torque and thermal rating at your actual speeds, its stated lost motion, its torsional stiffness, and the output bearing's radial and axial capacity for the spindle arrangement. Where that ratio enters the controller — reflected inertia and loop tuning — is worked through in the guide to where the gearbox ratio belongs in a servo axis simulation.

Keep the reduction even though a servo makes full torque at zero speed. Deleting the gearbox hands the entire spindle torque to the motor shaft continuously, which means a far larger motor and frame for no benefit at these speeds. And whatever the ratio, the joint where the gearbox output meets the spindle shaft takes a flexible shaft coupling, sized for the transmitted torque and for the residual misalignment between two shafts mounted separately.

What ratio does a geared induction motor need instead? #

A four-pole motor with a 1,450 rpm nameplate speed needs 145:1 to reach 10 rpm and lands at 9.7 rpm behind a 150:1 unit, while an 8-pole motor at 750 rpm synchronous speed needs only about 75:1 from its loaded plate speed.

Take the ratio from the loaded nameplate speed, never the synchronous speed: ratio = loaded motor speed / top spindle speed. A four-pole motor turns 1,500 rpm synchronous at 50 Hz; the loaded figure is on the plate, and this example takes 1,450 rpm, which divides to 145:1 at the top spindle speed. An eight-pole motor follows synchronous speed (rpm) = 120 × frequency (Hz) / pole count, so 750 rpm synchronous at 50 Hz and 900 rpm at 60 Hz; a plate near 720 rpm loaded gives 72:1. The eight-pole's real advantages are the lower ratio and a motor already running near line frequency — not torque.

The torque side comes from the same plate: rated torque (Nm) = 9,550 × power (kW) / speed (rpm). A 2.2 kW, 1,450 rpm motor is rated 9,550 × 2.2 / 1,450 ≈ 14.5 Nm, which behind 145:1 is roughly 2,100 Nm at the spindle before losses — about twenty times the requirement. Reversed, the steady winding duty needs about 0.77 Nm, roughly 116 W, at the motor shaft once 145:1 and a 0.9 efficiency are applied. If winding is the whole duty, the frame follows from acceleration and duty cycle and will sit nowhere near that plate; keep the plate figure only if the spindle runs a second, faster, power-hungry duty.

Efficiency for a high-ratio unit varies by type: multi-stage spur or helical sets run near the 0.9 used above, as a rule of thumb, while worm sets run lower and usually resist back-driving — take the real figure and the thermal rating from the datasheet. And whether to reach low spindle speed by gearing or by slowing the motor electrically is the trade worked through in the guide to choosing a VFD or a gearbox to slow a motor; gearing keeps the motor near its rated speed, where its fan and its torque curve work as designed.

Will the motor overheat on continuous duty at low speed? #

Yes, if the combination is chosen for continuous duty there: the geared induction motor still turns fast enough to spin its shaft fan, and the servo is selected from its continuous torque envelope at the operating speed, because peak torque is not a continuous rating and motor cooling falls with speed.

There is no universal minimum safe speed to quote. The limits are the motor's cooling at the speed it actually runs, the drive's ability to deliver the needed current there, the load torque itself, and the continuous envelope the manufacturer states for that motor-drive pair.

The induction route hides the problem well: the reduction does the speed-changing, so the motor runs near its rated speed while the spindle crawls, the shaft fan keeps working, and the winding duty loads the motor only lightly. The build that does overheat is an ungeared motor turning a few rpm at full load torque with almost no fan flow; that build needs the manufacturer's low-speed duty data or forced ventilation before it runs continuously.

The servo route has the opposite shape: torque at crawl speed is its home ground, but the continuous envelope at the operating speed governs, not the peak curve, and a servo holding torque while nearly stationary heats with no airflow at all. Size on the stall or low-speed continuous figure on the datasheet, and let peak torque serve only the acceleration bursts it is rated for.

One commissioning check settles the question for your machine: run the winding cycle end to end at its worst continuous point and watch motor temperature against the insulation class limit the manufacturer states. That is a measured result for your machine, and no calculation replaces it.

Which drivetrain do I order for each duty? #

For continuous winding where the traverse follows measured spindle turns, order the VFD, gearbox and spindle encoder and let electronic gearing in the motion controller hold the ratio; for commanded angles or coordinated paths, order the servo with the reduction from the torque arithmetic above.

Continuous proportional following: the spindle encoder feeds the controller, the traverse becomes a follower axis — the same arrangement as making a follower axis track a master axis with electronic gearing — and the acceptance check is that traverse travel per spindle revolution stays correct through the whole speed profile, slower over the ends and faster on the barrel.

Commanded angle, hold, or coordinated rotary-linear motion: a servo spindle axis, sized on continuous torque at its 50 to 150 rpm motor speed with the 10:1 or 15:1 reduction, accepted at a settled spindle within the required angular error under load. An AC servo, a DC servo or a BLDC all close that loop the same way; the arithmetic above is drive-agnostic.

Both duties in one machine: the servo sized for the continuous winding duty. A speed-mode VFD cannot serve the positioning half regardless of how steady its speed regulation looks on an instrument.

Write the acceptance requirement before ordering: traverse travel per spindle revolution, or spindle angular error under load. If the machine needs both, only the servo architecture closes both. One stopping note belongs with the order: IEC 60204-1 requires the machine's stop category to be chosen from its risk assessment, and a geared spindle carrying continuous torque will not coast to rest the instant drive power is removed.

Questions asked

Should the spindle encoder sit on the spindle or on the motor?

For electronic gearing it belongs on the spindle: the controller gears the traverse to the spindle's actual rotation, and a spindle-mounted encoder sees the drivetrain's compliance and lost motion as they really are. An encoder on the motor shaft measures the motor alone, so gearbox wind-up and lost motion appear as traverse-to-spindle error that no tuning can remove.

Can one drivetrain do the winding duty and occasional angular positioning?

Only with a servo sized for it. Pick the motor on continuous torque at the operating speed with the reduction already chosen, run the winding profile as geared or programmed motion, and treat indexing as a normal positioning move. A speed-mode VFD cannot join that job, because the positioning half needs a drive that closes a position loop.

Is the 12 Nm figure on a servo datasheet safe to use in the ratio calculation?

Only after checking which torque it is. Datasheets state peak and continuous ratings along the torque-speed curve; the ratio arithmetic must use the continuous torque available at your motor speed, here roughly 50 to 150 rpm. Peak ratings cover acceleration bursts of limited duration as defined by the manufacturer's curve and duty limits.

How does gearbox lost motion affect a winding machine?

It matters when the axis reverses or holds under a changing load: the motor can turn through the lost-motion angle before the spindle follows. One-direction winding barely registers it; commanded positioning lands it directly in the angular error budget. Check the stated lost motion of the exact gearbox, and let the ratio and stiffness carry the error budget.

Keep reading

  • Selection guide

    Choosing VFD or gearbox to slow a linear actuator motor

    Choose the mechanical reduction first: a gearbox multiplies the motor's rated torque by the ratio (times roughly 90-95% efficiency), while a VFD only holds rated torque and loses shaft-fan cooling below about half speed. Gear a 1/8 HP motor so it runs at rated speed at maximum travel speed; add a VFD only when travel speed must vary.

    Motors, gearboxes and drives sizing

  • How-to

    How to Choose Servo Gearing for a Ballscrew Router Axis

    Run 3:1 to 4:1 belt reduction on the X and Y axes and 2:1 on Z. The ratio comes from required rapid speed and the continuous torque rating, not the 190 oz-in stall figure; above about 4:1 a single timing-belt stage needs pulleys that do not fit a router.

    Motors, gearboxes and drives sizing

  • Explainer

    AC servo motor and VFD compatibility: what decides it

    A general-purpose V/Hz VFD cannot commutate a permanent-magnet AC servo: reported bench runs pushed 10–12 A into a 2 A motor with no usable torque, and a second servo grumbled and stalled. Buy a drive that documents the motor type, its feedback interface and a speed-control firmware variant, or a matched motor–amplifier pair, and commission uncoupled at the lowest command.

    Motors, gearboxes and drives sizing