How-to
Mounting a concentrated mass on a robot arm link
Short answer
Treat a 3 to 4 kg attachment bolted to a robot arm link as a link load-model change, not a bigger tool payload: it adds 29 to 39 N and a gravity moment equal to weight times the perpendicular lever arm, which changes with pose. Weigh the complete assembly, find its center of mass and lever arms, keep the bulk feeder on an external support, and take the numbers to the robot manufacturer before any link mount runs.

On this page
- Does a 3 to 4 kg attachment on an arm link need a load-model change?
- What does the attachment's weight do to each joint axis?
- Which numbers do you measure before mounting the attachment?
- Why is a cable harness along the arm different from a bulk feeder?
- Can a tool payload setting or a calibration edit absorb the attachment?
- Where should a welding wire feeder sit instead of the arm?
- What do you send the manufacturer for approval?
- Questions asked
Treat a 3 to 4 kg attachment fixed to an arm link as a change to that link's load model, not as a larger tool payload. The attachment adds 29 to 39 N of weight, and what every joint upstream of the mount feels is that weight times the perpendicular lever arm from the joint axis to the attachment's center of mass, a quantity that changes with pose. A bulk mass bolted to one link behaves differently from a cable harness spread along the arm, and differently again from a load at the tool flange. Weigh the complete assembly, find its center of mass and lever arms, keep a bulk feeder on an external support by default, and take the numbers to the robot manufacturer before any link-mounted attachment runs.
Does a 3 to 4 kg attachment on an arm link need a load-model change? #
Yes: it changes the load model of the link that carries it, because the attachment adds 29 to 39 N of weight and every joint upstream of the mount feels a gravity moment equal to that weight times the perpendicular lever arm to the attachment's center of mass.
The controller corrects each joint against a model of every link: mass, center of mass and inertia, supplied by the maker, with the documented payload settings covering only what hangs at the tool flange. A mass bolted partway up the arm belongs in that internal model, and no payload field describes it. Until the model is corrected or the mass comes off, the arm under-compensates gravity at the joints that carry the attachment, and the controller's load monitoring reads a lighter arm than the one it is moving. Whether the error becomes visible path wander depends on the lever arms, the speeds and the accelerations; the model error itself is not in doubt.
What does the attachment's weight do to each joint axis? #
Each joint upstream of the mount feels a moment about its own axis, equal to the attachment's weight times the perpendicular distance from that axis to the center of mass; at a 0.30 m offset, a 3.5 kg assembly puts about 10.3 N·m on the joint that carries it.
The moment is pose-dependent: gravity points down, so the lever arm that counts is the perpendicular distance d from the joint axis to the center of mass, largest when the arm reaches out horizontally and nearly zero when the assembly sits directly over the axis. Size every check at the stretched-out pose. It is the same lever-arm rule covered in how torque depends on force and its perpendicular lever arm.
Worked example, calculated for these inputs and not a measured result: take a 3.5 kg assembly, the middle of the range. Weight W = m × g = 3.5 kg × 9.81 m/s² = 34.3 N. Worst case, arm horizontal with the center of mass 0.30 m perpendicular from the joint axis: M = W × d = 34.3 N × 0.30 m = 10.3 N·m. Across the full 3 to 4 kg range at that same offset, the moment runs from about 8.8 to 11.8 N·m. Move the mount twice as far out and the moment doubles; the lever arm is the lever, and mass alone decides nothing.
Rotation adds a second demand. About a joint axis, the attachment's inertia follows the parallel axis theorem, I = I_CoM + m × d², and for a compact bracket whose own I_CoM is small next to the transport term, that is about 3.5 kg × (0.30 m)² = 0.315 kg·m². Every joint that swings the link must accelerate that inertia on top of the original link's, with drive torque equal to inertia times angular acceleration, so the penalty grows with how hard the arm is thrown. The moment also loads the bracket and the link structure; if weld-path wander appears after mounting, measure it as described in measuring a robot arm joint's flex under load.
Which numbers do you measure before mounting the attachment? #
Four inputs decide the check: the installed assembly's mass, its center of mass, its perpendicular lever arm from each upstream joint axis, and its rotational inertia; weigh the complete assembly, not the feeder alone, and record every coordinate in a frame fixed to the mounting link.
- Weigh the complete assembly on a bench scale: bracket, fasteners, clamps and everything that moves rigidly with it, in its working state, because a full wire spool versus an empty one shifts both mass and center of mass.
- Identify the exact link the bracket bolts to, joint housing, upper arm casting or forearm; the word shoulder alone does not say which joint motions carry the mass.
- Locate the center of mass from a complete CAD mass-property calculation or from a hang-and-plumb-line measurement, and record the coordinates against datums on the mounting interface so they survive a bracket swap.
- Measure the lever arm from each upstream joint axis to that center of mass at the worst pose, arm horizontal and fully extended.
- Estimate the rotational inertia from the CAD model or from the parallel axis theorem in the previous section.
- Record the service forces: hose and cable tension at the extreme poses, the restraint points and the cable and hose makers' minimum bend radii.
Two assemblies with the same mass and the same center of mass can still differ in inertia, because inertia depends on how the material is spread. Treat mass, center of mass and inertia as three separate inputs, never one number.
Why is a cable harness along the arm different from a bulk feeder? #
A harness spread along the arm barely moves each segment's center of mass, because each segment's own mass dominates its share of the cable; a bulk feeder concentrates its full weight at one point on one link, so the moment arithmetic above applies at full strength.
Benign does not mean negligible. The harness still needs slack at every pose, restraint clips at defined points and the cable and hose makers' bend radii, because a taut service line pulls on the torch like a spring, and it pulls hardest at the extreme poses where the slack runs out. Decide the harness by its routing quality, not by its weight alone.
Can a tool payload setting or a calibration edit absorb the attachment? #
No: the tool payload setting models mass at the tool flange, so entering a link-mounted feeder there gives the controller the wrong lever arm and charges its weight to the wrong joints; the torch payload and an arm-link attachment are two separate load-model tasks.
The payload data describes whatever hangs off the flange, a torch, a gripper or a picked part, with mass and center of mass relative to the flange frame, and makers document how to update it, including at runtime while the program executes. Loads that genuinely live at the flange are a different job from a bracket bolted to the upper arm, and the flange case is what mounting a heavy gripper on a robot wrist flange covers.
If the maker approves a link mount, the corrected model is a combination, not a copy: r_combined = (m_link × r_link + m_attachment × r_attachment) / (m_link + m_attachment), with both position vectors in one frame fixed to the link, and it needs the link's own mass properties from the maker, inheriting every error in them. Keep any model change inside the maker's documented procedure: an unvalidated edit to the controller's internal model skews gravity compensation and the load monitoring the arm relies on to detect collisions, and the cell's risk assessment under ISO 10218, not this article, is the safety reference.
Where should a welding wire feeder sit instead of the arm? #
Put the feeder on an externally supported mount, a gallow beside the workspace or an overhead balancer, so its 3 to 4 kg never rides the arm; the hose and cables still follow the torch, and their tension through every pose is what remains to manage.
Size the gallow or balancer so the feeder covers the whole weld envelope without the hose dragging, snagging or pulling the torch off its commanded path, and leave enough service slack that every pose stays reachable. An external support takes the concentrated mass off the arm; it does not take the hose forces away, so check tension at the extreme poses with the services at full extension. Feeder behavior, wire push distance, gas delivery and spool access, belongs to the support design, not to the robot.
What do you send the manufacturer for approval? #
Send the manufacturer the mounting drawings, the measured mass, center of mass, lever arms and inertia, the service routing and the motion requirements, and ask for the approved way to update the arm's link load model before the attachment ever runs.
Send it through the maker's official support channel, not a forum: mounting drawings with the bolt pattern and the exact link, the measured mass properties from the list above, the routing and restraint plan for the services, and the motion requirements, poses, speeds, accelerations and the path accuracy the weld demands. Ask two questions directly: whether the maker approves an attachment at that mounting point, and which documented load-model update the controller supports for it. A no to the first settles the arrangement: relocate the feeder.
The decision, case by case:
- Harness spread along the arm: acceptable as a managed service, with slack at every pose, restraints at defined points, bend radii respected and tension checked at the extreme poses.
- Concentrated feeder on an arm link: only after written approval and a documented link load-model update built on the measured mass properties.
- Default with no approval cycle: a gallow or overhead balancer carries the feeder, and the arm carries only the torch and the managed harness.
Questions asked
How do I find a bracket's center of mass without a CAD model?
Weigh the complete assembly, then hang it from a string at two different points, one after the other, and mark the plumb line each time; the center of mass lies where the two marked lines intersect. Do the weighing with everything that moves rigidly with the bracket, including fasteners and a full consumable spool, and record the found point against two datums on the mounting interface, such as bolt-hole centers, so the coordinates survive a bracket swap.
How much torque does the attachment add during acceleration?
Multiply the attachment's inertia about the joint axis by that joint's angular acceleration. With the worked example's 0.315 kg·m² and a modest 1 rad/s², the added demand is about 0.315 N·m, and it scales in direct proportion to acceleration, so a fast pose change costs proportionally more. Fast swings also add centrifugal loads a static gravity check never sees; whether the joint holds that margin is a question for the arm's datasheet, not an assumption.
Can the robot's payload value change while a program runs?
Yes. Robot makers document script calls that change the active payload and center of gravity during execution; Universal Robots documents URScript functions for exactly this. Use those calls for loads that genuinely change at the flange, such as picking a part up or setting it down. Never use them to disguise a mass bolted to a link, because the model still points at the wrong frame and the wrong joints.
Where do the robot link's own mass properties come from?
From the robot manufacturer. Makers publish or supply the mass, center of mass and inertia of each link in the product's mechanical documentation or on request, and the controller's load model is built from those values. Do not estimate them by hefting the arm, because the combined center of mass calculation divides the weighted sum of link and attachment by their total mass and inherits every error in the link figures.