Selection guide
Selecting a hub-output planetary gearbox for a rotary table
Short answer
A hub-output planetary gearbox can carry a rotary platter directly only if its output bearing's permitted axial force and overturning moment cover the combined load; a centered 200 lbf load is about 890 N with near-zero moment. If the datasheet's combined-load envelope fails, support the table on its own bearing and let the gearbox transmit torque only.

On this page
A hub-output planetary gearbox can carry a face-mounted rotary platter directly, but only when its output bearing's permitted axial force, overturning moment and torque cover the combined load. For this case — 50:1 minimum reduction, a centered 200 lbf thrust on a roughly 20 in platter, an existing NEMA 34 servo and a 24 V or 48 V supply — the axial force comes to about 890 N, well within what documented gearhead families offer, but the datasheet's combined-load envelope still decides. If that envelope fails, support the platter on its own bearing and let the gearbox transmit torque only.
What the output must carry #
For a horizontal platter on a vertical axis, the weight of everything the platter supports — platter, fixture, workpiece — reaches the output bearing as axial force, on top of any process thrust. Confirm whether the stated thrust already includes the supported weight before comparing anything to a rating. The load path runs from the platter face through the hub or flange, the output bearings, the housing, the mounting plate and into the frame, so the whole chain shares the duty.
| Requirement | This case | Where it is fixed |
|---|---|---|
| Reduction | 50:1 minimum | table speed against available motor speed |
| Axial force at the output | 200 lbf ≈ 890 N stated thrust, plus any supported weight not counted yet | load schedule against the datasheet's permitted axial force |
| Overturning moment | near zero centered; up to 226 N·m if the resultant moves to the rim | load offsets against the datasheet's permitted moment |
| Output interface | hub or face flange to bolt the platter | output drawing: pilot, bolt pattern, fasteners |
| Part envelope | 20 in diameter, centered and roughly evenly distributed | fixture layout and actual center of mass |
| Motor interface | existing NEMA 34 servo, or a replacement | motor shaft drawing against the gearbox input adapter |
| Supply | 24 V or 48 V, no high voltage available | drive input specification and motor torque-speed data |
A shaft hub added to an ordinary shaft-output gearbox is only a mounting connection; it does not raise that gearbox's axial or moment rating. Only a unit whose output bearing system is itself rated for the load qualifies as the all-in-one solution.
Worked example: 200 lbf centered on a 20 in platter at 50:1 #
Inputs, each with its source:
- stated thrust: 200 lbf (the application requirement)
- platter envelope: 20 in diameter, load centered and roughly evenly distributed (largest part)
- conversion: 1 lbf = 4.448 N
- ratio: i = 50 (the minimum requirement)
The rule in words: the overturning moment is the axial force times its perpendicular offset from the rotation axis, and a centered resultant has zero offset. Load inertia reflected to the motor falls with the square of the ratio.
The arithmetic:
- Axial force: stated thrust × 4.448 N/lbf = 889.6 N ≈ 890 N.
- Rim boundary case: the largest possible offset is half the platter diameter, 10 in = 0.254 m, so M = F × e gives 2000 lbf·in ≈ 226 N·m. This is a geometric worst case, not the moment of the described centered load.
- Centered case: e ≈ 0, so M ≈ 0 and only the axial force reaches the bearing.
- Reflected inertia: J at the motor = J_load / i² = J_load / 2500. The rotating mass and its radial distribution are not stated, so J_load itself stays open until the platter and fixture are weighed.
Result: the output bearing must carry the converted axial force with near-zero moment for the centered load, and additionally the rim moment if the resultant can shift outward — under an off-center workpiece or a machining force.
Decision: a permitted axial force below 890 N, or a permitted moment below 226 N·m at that axial force on the combined-load curve, disqualifies direct mounting; support the table on its own bearing. Both passing, with margin for the platter and fixture weight not yet counted, qualifies the hub-output unit.
Reading the permitted load in the datasheet #
Take the numbers from the datasheet of the exact gearbox, not from a family brochure. One documented planetary gearhead family, for example, lists output bearings with radial capacity up to 13,810 N and axial capacity up to 18,530 N, which shows this class of duty is within reach of the technology — but those figures belong to that family and are stated as separate maxima. Separate maximum ratings are usually not simultaneously usable: manufacturers publish a combined-load curve or table that derates axial capacity as moment and radial load rise, and bearing fatigue life per ISO 281 depends on both load and speed, so a load inside the maxima can still shorten life at high duty. Check three things in order: permitted axial force at the output, permitted moment, and the combined-load curve at your actual operating point.
If the bearing check fails: support the platter separately #
Mount the table on its own bearing arrangement — a pair of spaced bearings in a housing, or a slewing ring for larger platters — so the table structure carries the weight and moment while the gearbox transmits torque only. Connect the gearbox output to the table shaft with a flexible shaft coupling sized to absorb the small alignment errors between the two bearing systems; a rigid connection would make the gearbox output bearing a second, conflicting support and reintroduce the load you just removed. This architecture costs a support housing and a coupling; it buys a load path you size independently of any gearbox catalog.
Motor torque, speed and the supply #
Output speed is motor speed divided by the ratio, so table speed fixes the motor's speed band. For steady rotation, output torque is motor torque times the ratio times efficiency: T_out = T_motor × i × η, with η taken from the gearbox datasheet at the operating point — never assume 100 percent. Acceleration adds T_accel = J_load × α on the output side; because the reflected inertia at this ratio is divided by 2500, the motor and gearbox inertia usually dominate, which is why the acceleration check belongs at the motor shaft. The torque breakdown is worked through in calculating servo axis acceleration for torque sizing.
Run the drive at 48 V if its input range allows: for the same power, motor current halves compared with 24 V, which shrinks the peak demand on the supply and wiring during acceleration. Check the motor's torque-speed curve at that bus voltage, because a servo delivers less usable torque at lower bus voltage, and confirm the gearbox input adapter matches the NEMA 34 flange and shaft, or those of the replacement motor.
The decision in one pass #
- Total the axial load: stated thrust plus every supported weight not yet counted, converted to newtons.
- Take the permitted axial force, permitted moment and combined-load curve from the exact gearbox datasheet.
- Pass on all three with margin — mount the platter on the hub output. Fail on any one — support the table on its own bearing and couple it for torque only.
- Then verify motor torque at the ratio on the 48 V supply, and the input adapter fit, before placing the order.
Questions asked
Does a ratio above 50:1 make the selection easier?
Not automatically. A higher ratio multiplies motor torque further and shrinks reflected inertia faster, since the divisor grows with the square of the ratio (at 60:1 it is 3600 instead of 2500), but the motor must spin proportionally faster for the same table speed and stay inside its torque-speed curve at the available 48 V. Take the lowest ratio that meets table speed and torque; the bearing loads do not improve with ratio.
The stated thrust does not include the platter and fixture weight. Does that change the bearing check?
Yes. Add the weight of everything the platter carries before comparing with the permitted axial force. On a vertical axis that weight is pure axial load on the output bearing; on a horizontal axis the same weight arrives as radial load plus a moment instead, so the mounting orientation decides which rating row you check first.
What must the mounting plate between gearbox and platter do?
It must present a flat, stiff face square to the output axis. A plate that flexes under load tilts the platter, turning part of the axial force into an overturning moment and a radial load on the output bearing. Bolt the plate to the machine frame, not only to the gearbox housing, so the load path ends in the structure, and verify loaded versus unloaded platter runout after assembly.
The old gearbox failed with no clear symptom. What should be recorded before ordering a replacement?
Record the failure mode, not just the part number: loaded versus unloaded runout at the platter, commanded versus actual speed and drive current against the motor's torque-speed curve, gearbox and motor temperature over a duty cycle, and position error after direction reversals. Tilt points at the output bearing, a speed shortfall at insufficient motor torque, drift after reversal at backlash or a loose hub joint.