AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Explainer

Running a 6-wire unipolar stepper motor on a bipolar driver

Servo and stepper motion Published 6 min read By AutomateDirectUSA engineering team

Short answer

A 6-wire unipolar stepper motor runs on a bipolar driver with both centre-tap leads left unconnected and insulated, and the driver current set to about 0.7 times the unipolar winding rating. The step angle does not change: it comes from rotor and stator tooth geometry, not from how the winding is connected. A 5-wire motor cannot be wired this way.

On this page
  1. What the wire count tells you
  2. Why the step angle does not change
  3. What the series connection does electrically
  4. The real cost: torque at speed
  5. Wiring the conversion
  6. Verifying the result
  7. The decision for each motor
  8. Questions asked

Yes: a 6-wire unipolar stepper motor runs on a bipolar driver. Leave both centre-tap leads unconnected and individually insulated, wire each winding's two outer ends to one H-bridge output pair, and set the driver current to about 0.7 times the motor's unipolar per-winding current rating. The step rating does not change: a motor sold as 1.8 degree stays 1.8 degree and a 0.9 degree motor stays 0.9 degree, because step angle comes from rotor and stator tooth geometry, not from the winding connection. A 5-wire unipolar motor cannot be converted this way, and a 4-wire bipolar motor cannot run on a unipolar driver.

What the wire count tells you #

The number of leads tells you whether both ends of each winding are reachable. A bipolar driver reverses current through a whole winding with an H-bridge, so it needs both ends of each coil.

Motor Construction Works on a bipolar driver? Works on a unipolar driver?
4-wire Two coils, two ends each Yes, native No, no centre tap to switch against
5-wire Both centre taps joined internally No, only one end of each phase pair is reachable Yes
6-wire Two coils, each with its own centre tap Yes, centre taps left open Yes, centre taps to the supply

The 5-wire motor fails because the shared common prevents independent access to the two outer ends of each phase. Before wiring anything, identify the layout with an ohmmeter: three leads per phase with end-to-end resistance about twice end-to-centre resistance means a 6-wire motor; one lead with continuity to all others means a 5-wire common.

Why the step angle does not change #

Step angle is fixed by the rotor and stator tooth geometry. Full-step drive of a 200-step motor gives 1.8 degree per step; half-step gives 0.9 degree. Switching from unipolar to bipolar excitation changes the current path through the copper, not the pole positions, so the same step sequence yields the same angle per step. A motor sold as 0.9 degree is a 400-step motor in full step and does not become 1.8 degree by dropping the centre tap.

Microstepping subdivides that angle through the current ratios between the two phases. That is a property of the driver, not of the winding, and it works identically on a series-connected 6-wire motor and a native 4-wire motor.

What the series connection does electrically #

In unipolar drive only half of each phase winding carries current at any moment. With the centre tap open, the full winding carries current in series. For a closely coupled winding with resistance R and inductance L per half, the general relationships are:

Quantity Unipolar (half winding) Bipolar series (full winding)
Resistance per phase R about 2R
Inductance per phase L about 4L, since inductance scales with turns squared
Current for equal copper loss I I divided by the square root of 2, about 0.7 times I
Heat produced at that current I squared times R the same, by design

The equal-loss step: unipolar dissipation per phase is I squared times R. A series bipolar phase at current I_b dissipates I_b squared times 2R. Setting the two equal gives I_b = I divided by the square root of 2, which is about 0.71 times I. That is where the 0.7 derating comes from; it keeps the copper loss unchanged, not reduced.

Worked example, for illustration only, using representative values: a motor rated 1.0 A per winding with 4.0 ohm measured end-to-centre and 2.0 mH end-to-centre.

  • Series resistance: 2 x 4.0 ohm = 8.0 ohm.
  • Series inductance: about 4 x 2.0 mH = 8.0 mH.
  • Series current for equal heat: 1.0 A divided by the square root of 2 = about 0.71 A.
  • Check: 1.0 squared x 4.0 = 4.0 W; 0.71 squared x 8.0 = about 4.0 W. Equal, as intended.

Before setting anything, read the datasheet of your exact motor to confirm whether the current rating is stated per half winding or per phase. Mixing those two bases either overheats the motor or starves it of torque.

The real cost: torque at speed #

The higher inductance is the practical limit, not the low-speed torque. Current rise time in a winding follows the L over R time constant, and the series connection multiplies that time constant by about two (4L over 2R), so current cannot fully build within each step period as speed rises. A series-wired motor loses usable torque at a lower speed than the same motor in unipolar mode unless the supply voltage rises to compensate. Use a chopper driver with a supply well above the motor's voltage rating so current stays regulated at speed; the winding-voltage story behind the nameplate is covered in Stepper motor voltage rating: what the 5 V nameplate means, and the torque-versus-speed trade is worked through in Stepper motor max RPM: torque curve, voltage and accel.

Wiring the conversion #

  1. Identify the two phases by resistance. Each phase has three leads: end A, centre tap, end B, with end-to-end reading about twice end-to-centre.
  2. Confirm the phases are separate: no continuity between any phase 1 lead and any phase 2 lead.
  3. Insulate each centre-tap lead individually so it cannot touch the frame or another lead.
  4. Connect phase 1's two outer ends to the driver's A+ and A- outputs, and phase 2's outer ends to B+ and B-.
  5. Set the driver current to about 0.7 times the unipolar per-winding rating from the datasheet, and select the step mode.
  6. Command a slow rotation. If the motor vibrates or rocks without turning, swap the two leads of one phase.

Never tie a centre tap to the supply while the outer ends are driven from an H-bridge: that shorts a half-winding across the bridge.

Verifying the result #

Command a known step count and mark the shaft. A 1.8 degree motor turns exactly one revolution in 200 full steps or 400 half steps; check for lost steps over several revolutions at your target speed. Then measure case temperature after a thermal soak at the commanded standstill current.

The temperature result tells you which fault you have, if any. A motor hotter than its datasheet limit is carrying unipolar current through the series winding, a current-setting fault. A motor that stays cool but stalls only above a certain speed is current-starved by inductance, a supply-voltage fault. Low-speed vibration with correct current and a cool motor points to swapped phase leads. Winding-related heating generally is treated in Why a Stepper Motor Runs Hot: Winding Connection and Phase Current.

The decision for each motor #

For a 6-wire motor destined for a bipolar chopper driver: wire it in series with both centre taps open and insulated, set the driver to about 0.7 times the unipolar rating, keep the stated step angle, and accept the earlier torque rolloff or raise the supply voltage to buy it back. For a 5-wire motor: it cannot be run on a bipolar driver at all, so keep a unipolar driver or replace the motor. For a 4-wire motor: bipolar driver only. Keep the existing unipolar drive if your speed range is high and the torque is adequate; converting to bipolar series pays off when the application holds load at standstill or at low speed, where the series connection uses the full copper and delivers more torque at the derated current.

Questions asked

Can a 4-wire bipolar motor run on a unipolar driver?

No. A unipolar driver works by switching each half-winding to supply through a centre tap, and a 4-wire motor has no centre tap to switch against. Reversing current through a whole winding needs an H-bridge, so a true bipolar motor requires a bipolar driver.

Why will a 5-wire stepper not convert to bipolar?

In a 5-wire motor the two centre taps are joined internally into one common lead, so the outer ends of each phase cannot be reached independently. Only constructions that expose both ends of each winding work on a bipolar driver: the 4-wire and 6-wire motors.

My motor overheats after converting to bipolar series. What went wrong?

The driver is almost certainly still set to the unipolar current while the full series winding is connected, roughly doubling the copper loss. Set the driver to about 0.7 times the unipolar winding rating and re-check case temperature against the datasheet limit after a thermal soak. If the motor is hot even at the derated current, confirm the datasheet rating basis before going further.

Keep reading

  • How-to

    Stepper driver error output wiring to the controller

    Wire each open-collector error output to its own controller input as a motion-stopped signal — never to the Enable inputs. A driver that faults has already stopped its own axis; the controller reads the input, halts coordinated motion, and blocks restart until the fault clears. Commission eight-wire motors in series first; go parallel only when speed demands it.

    Servo and stepper motion

  • Explainer

    Why a Stepper Motor Runs Hot: Winding Connection and Phase Current

    Copper loss sets stepper heat: current squared times winding resistance, summed over the energized sections. The driver's current setpoint and the winding connection decide it; the supply voltage mostly sets torque at speed. Wire the motor half-coil, bipolar parallel or bipolar series for the torque-speed curve the axis needs, set current to that connection's rating with the driver's documented setting equation, drop the current when the axis idles, and judge the result by stabilized case temperature and position retention.

    Servo and stepper motion

  • Selection guide

    Wiring a unipolar stepper motor over Cat5 or shielded cable

    A 6 V, 1.2 A unipolar phase sits well inside the roughly 2 A control-circuit figure cited for Cat5's 24 AWG, so short fixed runs work. Voltage drop, the six-lead count and solid-conductor fatigue decide the real selection: a stranded, individually shielded multi-pair cable with its shield bonded at the driver end.