Wiring a unipolar stepper motor over Cat5 or shielded cable

Servo and stepper motion Published 8 min read By AutomateDirectUSA engineering team

Short answer

A 6 V, 1.2 A unipolar phase sits well inside the roughly 2 A control-circuit figure cited for Cat5's 24 AWG, so short fixed runs work. Voltage drop, the six-lead count and solid-conductor fatigue decide the real selection: a stranded, individually shielded multi-pair cable with its shield bonded at the driver end.

On this page
  1. What the Cat5 gauge may carry
  2. Sizing the voltage drop for a 6 V, 1.2 A motor on a 3 m run
  3. Six leads decide the construction
  4. Shield, flyback and why no plug
  5. The selection: Cat5 against shielded multi-pair cable
  6. Hooking it up in order
  7. Reading a fault on the cable you chose
  8. The decision
  9. Questions asked

On paper, Cat5 passes: the jacket says 24 AWG, control-circuit practice cites about 2 A for that gauge, and a 6 V, 1.2 A unipolar phase sits well inside it, which is why bench machines run on it. The cable to select is a stranded, individually shielded multi-pair, three 22 AWG pairs and one 20 AWG pair, with its shield bonded at the driver end. Four things overrule the bare gauge check, and each has a number: voltage drop at 0.084 Ω per metre per conductor, the six-lead count, solid-conductor fatigue, and flyback spikes on the winding leads.

What the Cat5 gauge may carry #

The jacket marking on Cat5 is 24 AWG, and the NFPA control-circuit rules are cited at 2 A for that gauge. Your motor's rated current of 1.2 A uses about 60 percent of it. That is a ceiling with margin, not a target: the figure exists for wires feeding relays and inputs, and you are running a chopped inductive load through it.

Ampacity answers only the heating question. The note under NEC Table 310.15(B)(16), formerly Table 310.16, says its allowable values are based on temperature alone and do not take voltage drop into consideration. So the gauge check clears the cable thermally and says nothing about what actually reaches the winding. That is the next check, and it is the one that decides run length.

Sizing the voltage drop for a 6 V, 1.2 A motor on a 3 m run #

Take the bench case and put numbers on it.

Inputs:

  • Phase current: 1.2 A, the motor's rated current, off its datasheet.
  • Winding supply: 6 V, the motor's rated voltage, as a fixed-voltage connection.
  • Conductor resistance: 0.084 Ω per metre per conductor, the standard copper-table value for 24 AWG; confirm it on the cable datasheet.
  • Run: 3 m each way, an example bench-to-driver run. Substitute your own length.

The rule in words: the phase current crosses the cable out and back, so the loop is twice the run length, and the drop is the loop resistance times the current. Compare that drop with the winding supply, because a fixed-voltage drive hands the difference straight to the winding.

The arithmetic:

  • Loop length: 2 × 3 m = 6 m
  • Loop resistance: 6 m × 0.084 Ω per metre = 0.504 Ω
  • Drop: 1.2 A × 0.504 Ω = 0.60 V
  • Share of supply: 0.60 V ÷ 6 V = 10 percent, so the winding sees about 5.4 V

That is a calculated example for these inputs, not a measured result.

The decision: 10 percent is twice the 5 percent overall drop the NEC recommends staying within on supply conductors, so single Cat5 conductors are too thin for this run. The same arithmetic puts the single-conductor limit at about 1.5 m of run: 0.30 V, which is 5 percent of the supply, divided by 1.2 A gives 0.25 Ω, and 0.25 Ω divided by 0.084 Ω per metre is about 3.0 m of loop, or 1.5 m each way. At 3 m, parallel two conductors per lead and the drop halves to 0.30 V, back on budget. A constant-current chopper drive pays the drop out of its supply headroom and holds the winding current regardless; a winding connected straight across the supply loses it as torque, volt for volt.

Six leads decide the construction #

A unipolar motor brings out six leads: two windings, each with a centre tap. Identify them with an ohmmeter before anything else. From a tap to either end of its winding you read about half of the end-to-end resistance, and the two taps are the leads that read to four others. What the winding connection then does to heat and torque is covered in how winding connection and phase current heat a stepper.

The count rules cables out fast. A shielded 4-core microphone cable of 0.75 mm², flexible as it is, cannot reach six leads. Cat5 has eight conductors, so it fits the count. The multi-pair cable fits it better: put both ends of one phase in a 22 AWG pair, both ends of the other phase in a second pair, and the two centre taps on the 20 AWG pair. A tap carries current whenever its phase is on, and on two-phase-on drives both taps carry continuously, so the taps get the heaviest conductors.

Shield, flyback and why no plug #

Buy the construction, not just the copper: individually shielded pairs inside an overall shield, and bond the shield at the driver end only, to the chassis or protective-earth point. One bond drains interference without giving it a loop to travel.

The winding is an inductor, and that is the last strike against treating these leads as plain power wiring. When the driver switches a phase off, the stored energy drives current back out through the leads and the driver's flyback path, so the conductors carry peaks above the rated current and the spikes ride far above the supply rail. Treat the motor leads as live whenever the drive is enabled, low supply voltage or not. Keep the driver's clamp or flyback path intact and keep the run short; how large the peaks are depends on the winding inductance and the drive type, so read both datasheets rather than trusting a rule of thumb.

Terminate on screw terminals or ferrules. RJ45 contacts are not rated for sustained motor current, let alone the spikes, and a plug that small on a phase lead is a failure waiting for a maintenance visit.

The selection: Cat5 against shielded multi-pair cable #

Three candidates, one motor. The drop figures are loop values, out and back, at the rated phase current, per metre of run.

Criterion Cat5 Individually shielded multi-pair 4-core microphone cable
Conductors 8 × 24 AWG, solid 3 × 22 AWG pairs + 1 × 20 AWG pair, stranded 4 × 0.75 mm², stranded
Covers six leads Yes, two spare Yes, two spare No
Drop per metre of run at the rated current 0.20 V 0.13 V, and 0.08 V on the 20 AWG pair 0.055 V
Current margin Uses 60 percent of the 2 A control figure About 1.6 times the copper cross-section of 24 AWG (22 AWG), 2.5 times (20 AWG) Plenty of copper, wrong conductor count
Flexing Solid conductors crack at terminations Stranded, suits a cable track Very flexible, wrong count
Shielding None Pair shields plus overall shield One overall shield
Select it for Fixed, short runs Moving axes, longer runs, this motor A 4-lead bipolar motor only

The microphone cable is in the table to show why flexibility alone does not qualify a cable: the lead count fails before anything else matters.

Hooking it up in order #

  1. Identify the six leads with an ohmmeter: each centre tap reads about half of its winding's end-to-end resistance to both ends. Label A, A', tap A, B, B', tap B.
  2. Confirm the rated phase current on the motor datasheet and the gauge printed on the jacket, and redo the drop arithmetic with the current you find if it differs from the example.
  3. Assign pairs: one phase's two ends in a 22 AWG pair, the other phase's ends in a second, both centre taps on the 20 AWG pair. On Cat5, parallel two conductors per lead for any run past the single-conductor limit.
  4. Bond the shield at the driver end only, to chassis or protective earth, and leave the motor end floating.
  5. Terminate phases on screw terminals or ferrules, never an RJ45 plug, and strain-relieve at the motor so termination flex never reaches the conductor.
  6. Power up and measure: voltage at the motor terminals under load against the driver output, a commanded step count against actual travel, and a scope on the step and direction lines while the motor runs. Spikes on those lines mean the control wiring is picking up the phases, and troubleshooting STEP/DIR wiring to a stepper drive walks that isolation.

Reading a fault on the cable you chose #

Separate the symptom from the cause, and check the cheap things first.

  • Lost steps or stalling at speed, cable cool. Check voltage drop first: meter across the motor terminals under load and compare with the driver output. Then noise: scope the step and direction lines at the driver with the motor running. Then flyback stress: inspect the driver's clamp components against its manual.
  • A hot connector or a soft spot in the jacket. Re-terminate first, because a high-resistance crimp is the cheapest cause and the most common. If the whole run warms evenly, clamp the phase current; it is higher than the label assumed.
  • A phase that drops in and out, motor weak or buzzing. Wiggle each lead with an ohmmeter across it: a solid conductor cracked at a termination reads open intermittently under movement. A run that flexes needs stranded cable, not a repair.

The decision #

Commit by case:

  • Fixed axis, run within about 1.5 m: single Cat5 conductors are acceptable. Keep the cable out of any cable track and off anything that moves.
  • Fixed axis, run from there up to about 3 m: Cat5 with two conductors paralleled per lead, which halves the drop.
  • Anything that moves, any run past 3 m, or phases routed next to logic: the stranded, individually shielded multi-pair, centre taps on the 20 AWG pair, shield bonded at the driver end, screw terminals or ferrules at both ends. The 22 AWG pairs carry the 5 percent budget to about 2.4 m of run; double them up beyond that.

For a servo axis the same three checks, current, drop and shield, run with different numbers, and servo motor power and encoder cable selection works them through for that drive family.

Questions asked

Is a shielded 4-core microphone cable enough for a six-lead unipolar motor?

No. Four cores cannot reach six leads, and even joining the two centre taps at the motor leaves five conductors to run. The 0.75 mm² microphone cable suits a 4-lead bipolar motor, not this one. Take a cable with at least six conductors; the individually shielded multi-pair type covers it with room to spare.

Why is the shield bonded at the driver end only?

A shield bonded at both ends can carry a ground-loop current between two earth points, and that current couples noise into the very conductors the shield should protect. One bond, at the driver's chassis or protective-earth point, drains interference without the loop. If the drive's documentation specifies bonding both ends, follow that instead; it assumes an equipotential earth that your machine may not have.

A connector feels warm after an hour. Is the gauge too small?

Probably not the conductor. At 1.2 A the whole 6 m loop of 24 AWG dissipates about 0.7 W, which you will not feel. A spot that is hot to the touch points to a high-resistance crimp or terminal, so re-terminate it and measure again. A run that is uniformly warm means the actual current is above what you assumed, so clamp the phase current instead of trusting the motor label.

Can the step and direction lines share the Cat5 cable with the motor phases?

Keep them out. The phase conductors carry chopped current and flyback spikes, and logic lines in the same unshielded jacket couple that switching in, which shows up as lost steps or direction glitches while the cable stays cool. Run the control signals in their own shielded cable, and where they must pass near the motor leads, keep a gap or cross them at right angles.

Keep reading

  • Comparison

    Servo or Stepper for Fast Start-Stop Feed Rollers

    At 28 in feeds and 100 bags/min, a 2 in roller peaks near 1,337 RPM with about 1,400 rad/s² of angular acceleration; through the 5:3 belt drive the motor sees about 2,230 RPM. That is deep in the torque cliff where a hybrid stepper keeps only a fraction of its low-speed torque and loses steps silently, so this machine takes a servo.

    Servo and stepper motion

  • How-to

    How to Add Series Resistors to Run a 5 V Stepper at 12 V

    Each energized winding path needs a series resistor that drops the difference between supply and winding rating at rated current — here about 6.9 Ω dissipating 6.9 W, so fit a 20 W part per center tap. One shared resistor in the board's supply lead sees both winding currents and drives a lone conducting path to about 1.7 A, so it is out. A higher supply restores torque at speed but does not silence full-step resonance.

    Motors, gearboxes and drives sizing

  • Explainer

    Why a 12-15 V supply caps stepper motor speed

    On a 12-15 V supply a stepper motor's top speed is capped by current rise time: when the step period drops below the winding's L/R time constant, current never reaches rated and torque collapses. The fix is a constant-current driver on a higher supply voltage and a low-inductance winding; more rotor poles buy resolution, not speed. Worked example: 1,000 rpm on a 4 mH, 3 ohm winding needs about 57 V.