AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Selection guide

Servo Motor Power and Encoder Cable Selection for One Drive Family

Servo and stepper motion Published 8 min read By AutomateDirectUSA engineering team

Short answer

Order one motor-power assembly and one encoder assembly per set, each named by function, both end connectors and finished length. Within this drive family the four power classes up to 750 W share compatible power-cable and encoder-cable interfaces, so a repeated catalog code is not a dual-purpose cable. The standard listing is 5 m; order 2 m as a special finished length, and check ASD-IF-SC5020 against your CN1 signal list before relying on it.

On this page
  1. What a repeated catalog code does and does not tell you
  2. Which sets share which cable
  3. Why the power and encoder assemblies are not interchangeable
  4. Ordering a shorter finished length
  5. ASD-IF-SC5020 on CN1: suitable, with a coverage limit
  6. The order line, set by set
  7. Before the first motion command
  8. Questions asked

The job: three Delta ASDA-A2 servo sets — two ECMA-C 10807SS and one ECMA-C 10604SS — with no motor-power or encoder cables, and three questions: does the repeated catalog code mean one cable serves both jobs, can the harness be ordered shorter, and is ASD-IF-SC5020 suitable? Order two separate assemblies per set: one motor-power cable, one encoder cable, each specified by function, both end connectors and finished length. The ASDA-A2 family shares interfaces across its 100 W, 200 W, 400 W and 750 W classes, so one pair of assemblies covers all three sets; a repeated code names the shared interface, not a dual-purpose cable. The catalog's standard assembly is 5 m and a shorter finished length, such as 2 m, is a special order through the supplier. ASD-IF-SC5020 fits the A2 series CN1 connector but exposes only 20 of its 50 pins — check your signal list against its terminal map.

What a repeated catalog code does and does not tell you #

The same code printed against the motor-power row and the encoder row is not a statement that one assembly serves both jobs. It tells you the two rows share an interface family. The rows are still two different assemblies, with different connectors, different wiring and different work to do. Confirm each row on its own before you order: the assembly description in words, the connector drawing for each end, and the pin-to-pin wiring behind it. The identity you purchase is the complete assembly — function, both end connectors, conductor specification and finished length — not the row, the code or the picture.

Where a catalog prints one code against both rows, resolve it with the supplier in writing: which assembly does the power row refer to, which does the encoder row refer to, and which connector drawing belongs to each. Keep those answers with the order.

Decision: two assemblies per set, ordered by function, even where the printed code repeats.

Which sets share which cable #

Both ECMA-C 10807SS sets are the 750 W-class sets in this job. The ASDA-A2 compatibility tables treat the four classes from 100 W up to 750 W as sharing one power-cable interface and one encoder-cable interface — the same connectors and the same pin assignments within each function — so the assemblies that fit the big sets also fit any drive-and-motor pair whose nameplate class is one of the others. For the ECMA-C 10604SS set, read the class from the motor nameplate and order against what it says, not against what the machine looks like. Confirm the row for your exact class in the manual's connection chapter before the order goes in.

Record the full motor model and the full drive model from each nameplate, and keep the two big sets labelled separately through ordering, delivery and installation, so harnesses never migrate between machines. If a nameplate is missing or unreadable, identify the motor before you order anything against it — identifying salvage robot servo motors before drive selection walks through that identification.

One more line on the order: a brake. If any of the three motors has one, the family overview lists the brake power connector as its own item, so confirm from that motor's documentation whether the brake leads ride inside the power assembly or need a separate documented assembly, and put it on the order explicitly.

Why the power and encoder assemblies are not interchangeable #

The power assembly carries the motor's current, and the heat it must live with follows that current. The encoder assembly carries low-level feedback signals from the motor's encoder back to CN2 on the drive, and what it must preserve is signal integrity: conductor layout, shield and terminations exist to keep position counts clean. A connector that mates is not a connector that matches — check the electrical specification as well as the shape.

Worked example, with illustrative inputs — take yours from the nameplate and the assembly drawing. Assume the nameplate lists a rated current of 2.8 A and the drawing gives a conductor loop resistance of 0.20 Ω. Heat in the copper follows P = I²R: 2.8 A × 2.8 A = 7.84 A², and 7.84 A² × 0.20 Ω = 1.57 W spread across the whole assembly — a warm cable, nothing more. Now put the same current through a single poor crimp that adds 0.5 Ω of contact resistance: 7.84 A² × 0.5 Ω = 3.92 W concentrated at one contact, which runs hot while the cable stays cool. That asymmetry is the diagnostic: heat at a connector points at contact resistance, not at cable length and not at drive tuning.

The failure signatures split the same way. Localised heat or a drive current error points at the power path: crimps, contacts, conductor size. A feedback alarm, or a drive that will not initialise, points at the encoder path: supply to the encoder, continuity, pin assignment, shield termination and routing. Check the harness before you touch the tuning, either way. When you trace the encoder path, the wiring has to agree with the drive's signal names, and matching encoder signal names between motor and servo drive is the reference for that job.

Ordering a shorter finished length #

The standard listing is longer than the machine needs and leaves roughly three metres of coil in the cabinet. The family supports shorter factory lengths: the ASDA-A2 manual's cable table prints the length as the final digit of the order code, 3 for 3 m and 5 for 5 m, and anything else goes through the supplier as a special-length order. A 2 m harness is a routine special order; what makes it right is the specification you attach to it.

Worked example: the routed distance from drive to motor is 1.4 m. Add a 0.3 m service loop at the drive end for connector access and a 0.3 m loop at the motor end: 1.4 m + 0.3 m + 0.3 m = 2.0 m finished. If the motor rides a moving axis, add travel and a bend allowance — 0.4 m of travel plus a 0.2 m loop brings the same run to 2.6 m. Order the result as the finished length and keep the calculation with the purchase specification.

State four things on the special order: the assembly's function, both end connectors, the finished length in metres, and how you measured it — connector face to connector face, service loops included. Say whether the route is stationary or moving, because continuous-flex construction and minimum bend radius are properties the supplier builds in, not properties you can add afterwards.

Do not field-shorten the standard assembly. Cutting it re-terminates the shield and the conductors outside the documented assembly, and a disturbed shield is how clean position counts turn noisy. Unless you can meet the manufacturer's documented assembly procedure with the right tooling, the special-length order is the whole fix.

ASD-IF-SC5020 on CN1: suitable, with a coverage limit #

ASD-IF-SC5020 is documented for the ASDA-A2 series as a CN1 easy-connection accessory: it replaces fiddly work on the drive's 50-pin CN1 connector with a terminal strip. The limit is coverage, not fit — the accessory exposes the commonly used 20 of those 50 pins. Whether it suits your machine is decided by your signal list, not by the connector.

List every control signal the machine needs at CN1: inputs, outputs, their commons, limits, enable, whatever you route to the drive. Tick each one against the accessory's terminal-to-pin map. If everything on the list is covered, order it. If a signal is missing, wire that one directly to CN1 following the drive manual's pinout — do not repurpose a neighbouring terminal, because each terminal label exists for a specific pin, and a borrowed terminal makes a fault that is miserable to trace.

It is a terminal accessory, not a harness. It changes nothing about the motor-power and encoder assemblies you order and does not extend them.

Decision: suitable for the A2 series CN1 if your signal list fits its terminal map; wire anything beyond the map directly to the connector.

The order line, set by set #

Everything above collapses into one order discipline: per set, two assemblies, each fully named. The table is the order line, and the decisions under it answer the three questions this job started with.

Order-line field What you state for these sets Confirm against
Assembly function Motor-power or encoder, one assembly of each per set Catalog row description and connector drawings
Motor and drive model Full nameplate model of each of the three sets Motor and drive nameplates
Power class Each motor's nameplate class Family compatibility tables
Drive-end connector Power assembly to the drive power connector, encoder assembly to CN2 Drive manual connection diagrams
Motor-end connector As drawn for the recorded motor model Motor connection drawing
Finished length The calculated result from the worked example, as a special length Supplier quotation and assembly drawing
Feedback type Absolute-type or incremental encoder assembly to match the motor Motor documentation
Brake Whether brake leads ride in the power assembly or need a separate assembly Motor documentation
CN1 access ASD-IF-SC5020 only if the signal list fits its terminal map Accessory terminal-to-pin diagram

The three decisions:

  • Repeated code on the power and encoder rows: order both assemblies, named by function. The repeated code identifies the shared interface family, never a single dual-purpose cable.
  • Length: the standard listing stands at 5 m; the shorter harness goes on the order as a special finished length with function, both connectors, the measured length and the route duty stated.
  • ASD-IF-SC5020: documented for this family's CN1 and suitable if your signal list fits its terminal map; anything beyond the map wires directly to CN1.

Before the first motion command #

One pass with the covers off, in this order:

  • Isolate, lock off and wait out the drive's documented discharge time before touching any connector.
  • With the harnesses disconnected from the electronics, check continuity against the approved pin-to-pin drawing, and keep insulation-tester voltage away from anything connected to drive or encoder electronics.
  • Reconnect each assembly to its own set and label the harness, so one motor's encoder can never land on another motor's drive.
  • Apply power with motion restrained, read the drive's feedback and status indications, then run a controlled move and check direction, position counts, current and connector temperature under load.

Questions asked

Can I cut a standard cable assembly down to the length I need?

Only if the manufacturer documents an assembly procedure for it and you can follow it with the correct connectors, crimp tooling and shield termination. Cutting a finished harness re-terminates the shield and conductors outside that documented procedure, which is how noisy position counts and intermittent faults begin. If you cannot meet the procedure, the fix is a special-length order built by the supplier.

Do absolute and incremental encoder motors use the same encoder cable?

No. The family's documentation lists absolute-type and incremental encoder cables as separate assemblies, so take the encoder type from your motor's documentation and order the assembly that matches it. The shared interface compatibility across the power classes says nothing about this: it tells you which motors one encoder assembly fits, not that one feedback type substitutes for another.

My CN1 signal is not on the ASD-IF-SC5020 terminal map. What now?

Wire that signal directly to CN1 on the drive, following the drive manual's CN1 pinout, and leave the accessory to carry only the signals it maps. Do not repurpose a neighbouring terminal to stand in for the missing pin: each terminal label exists for a specific pin, and landing two functions on one terminal creates a fault that is very hard to trace. Record the direct-wired signals on the machine's electrical drawing.

Does a longer encoder cable lose signal quality?

It works against you. For the same conductor, resistance rises with length, and a longer shield picks up more noise from the power wiring it runs past. Stay within the lengths the family documents for the assembly, route the encoder harness away from the motor-power wiring, and for any run longer than the documented range, ask the supplier what the assembly is specified for instead of extending it yourself.

Keep reading

  • Troubleshooting

    Does the servo motor fault follow the drive or the branch

    Swap one boundary at a time between two compatible drive channels; if the fault stays on the same physical drive channel, replace that drive. If the fault moves with the motor power and feedback cables, the motor, cable, connector or mechanical load is at fault. Read the drive's data tag before ordering any replacement.

    Servo and stepper motion

  • Selection guide

    Selecting a Servo Motor and Drive for a CNC Retrofit

    Size the axis before the motor: shaft torque and speed, reflected inertia, then one documented command architecture — step-and-direction position mode for most G-code retrofit controllers. Before buying, verify the pulse arithmetic: motor rpm times commanded pulses per revolution, divided by 60, must sit under both the controller's output ceiling and the drive's documented input limit.

    Servo and stepper motion

  • Selection guide

    Servo drive selection for rigid tapping spindle and feed axes

    Select the tapping drive pair by whether the interface keeps feed position locked to the spindle's actual angle, not by which protocol is easier to wire. At the spindle's rated 2000 rpm the feed must run 2000 times the thread lead in millimetres per minute, and the 5 Nm spindle rating works out to about 1.05 kW of shaft power. Two independent pulse-train axes need a tension-compensating tap holder or a controller that gears feed to measured spindle angle.

    Servo and stepper motion