How-to
Running a 90 VDC Gear Motor on a Step-and-Direction Drive
Short answer
Yes, a 90 VDC gear motor with a quadrature encoder runs well on a step-and-direction servo drive, but only if the DC bus stays below the drive's maximum input. Set the supply to about 75 VDC on a drive rated 80 V maximum, wire one drive per axis with its own encoder feedback, and delete the 24 V direction relays: the drive reverses the motor internally.

On this page
A 90 VDC gear motor with a high-resolution quadrature encoder is a natural fit for a step-and-direction servo drive: the drive closes the position loop from the encoder, reverses the motor electronically, and takes step and direction straight from CNC software such as TurboCNC or Mach2. The one hard rule is voltage. A drive with an 80 V maximum supply input must never see the machine's existing 90 VDC supply, because an unregulated or lightly loaded DC supply can sit above its nominal rating and destroy the drive's output stage. Turn the adjustable supply down to roughly 75 VDC, verify it at the drive terminals under load, and the conversion works. The relays and the parallel-port relay idea drop out of the design entirely.
How the architecture replaces the relay panel #
Each axis gets one encoder-input servo drive between the controller and the motor. The signal chain is:
- G-code software on the PC issues step and direction per axis.
- The drive receives step and direction and its motor's quadrature encoder feedback.
- The drive commands the brushed DC gear motor, reversing it internally from the direction signal.
With that chain in place, the existing variable-speed controller and its 24 V direction relays have no role in positioning. A relay cannot follow step pulses, and direction is decided inside the drive. Reading the encoders into the computer while relays switch the motor does not close a loop: software encoder inputs display position, they do not control the motor. Unless the software and interface documentation explicitly verify closed-loop control through such hardware, do not build it.
For pulse scaling on a geared axis, work the numbers the same way as in how to calculate step and direction servo pulse scaling, with the gearbox ratio included in the denominator.
Match the drive to the motor current #
The motor draws about 0.83 A at full load at its rated voltage. Check the selected drive's continuous current rating against that figure, and remember that motor current follows torque, not bus voltage: a slow heavy cut at a low commanded speed can draw nearly full-load current while the bus sits at 20 to 30 V. The assumption that current "will be a little higher but not much" at low voltage is not something you can confirm from the nameplate; measure it during a representative cut.
| Item | Value | Decision it drives |
|---|---|---|
| Motor rating | 90 VDC, about 0.83 A full load | Drive continuous current must cover full load plus stall and acceleration |
| Drive supply maximum | 80 V stated for this drive family | Bus must stay below this at all times |
| Conservative bus setting | about 75 VDC | Set the supply and verify under load |
| Cutting bus | 20 to 30 V during slow routing | Measure motor current; do not infer it from voltage |
Setting the bus voltage for a 90 VDC motor on an 80 V drive #
Inputs:
- Motor rating: 90 VDC, from the gear motor nameplate on the saw's X, Y and Z axes.
- Drive supply maximum: 80 V, stated by the drive maker for this drive family.
- Supply type: an adjustable DC supply already on the machine, currently set near 90 V.
The rule: the DC bus at the drive terminals must stay below the drive's maximum input rating at all times, including light-load and regeneration conditions, with margin for supply regulation error and measurement drift.
The arithmetic: take the 80 V maximum and reserve roughly 6 percent margin for regulation and meter error: 80 V x 0.94 = 75.2 V, so set the supply to about 75 VDC. Confirm with a meter at the drive terminals: first at no load, then while the motor holds against a load, since an unregulated supply that reads 90 V open-circuit can sag or, with some regulation schemes, rise above its setpoint depending on load.
The result: a bus of about 75 VDC, roughly 6 percent under the drive's limit and 17 percent under the motor's rating.
The decision: above the drive's 80 V maximum, do not connect the drive at all; at or below about 75 VDC, connect it. The cost of the lower bus is top speed: the motor's no-load speed falls roughly in proportion to the bus, so a motor that turned full speed at 90 V turns about 83 percent of that at 75 V. For a saw that routes sink holes at slow feed rates, that margin costs nothing.
Commissioning steps #
- Record each motor's encoder voltage, output type and counts per revolution from the encoder's own datasheet; a high-resolution encoder on a salvage motor often needs a 5 V supply the drive does not provide, so check before wiring. Where levels differ, the considerations in connecting a 5V servo encoder to 24V PLC inputs apply to matching signal levels between devices.
- Set the adjustable DC supply to the conservative bus voltage and measure it at the drive terminals, unloaded and loaded.
- Connect each axis encoder to its own drive, then step and direction from the computer interface. Keep encoder cable runs away from motor leads.
- Energize one axis at a time. Jog at low speed, confirm direction matches the software's expectation, and reverse the direction signal or swap motor leads consistently if not.
- Tune each drive per the maker's procedure, with current limit set low at first so a tuning error cannot slam the axis.
- Verify position tracking over a known travel without cutting load, then with the machine doing its real work: acceleration, the slow deep cut, stop, and reversal.
- During that test, log bus voltage and motor current and confirm neither reaches the drive's ratings.
Plan for power loss and re-referencing #
Encoder-based position is only valid while the drive is powered. After any shutdown or power glitch, the axes may not know where they are, and on a machine cutting granite an uncommanded restart in the wrong place ruins the part or the bit. Define a restart procedure: power up, re-reference every axis to its home switch or a known fixture position, and only then load G-code. If the machine cannot tolerate an interruption mid-cut, a UPS for the computer and drive logic buys an orderly stop; size it for the actual loads, and still expect to re-reference after a hard power loss.
Safety note #
A brushed DC drive connected to a mis-set supply fails unpredictably, and a granite saw stores serious mechanical energy in its motion. Verify the bus voltage with the drive disconnected, set the drive's current limit before first motion, and test each axis with the cutting head clear of the workpiece before any loaded cut.
The decision, per case #
- Motor rated 90 VDC, drive supply maximum 80 V: do not connect the existing 90 V supply. Set the bus to about 75 VDC, measure it at the drive, then connect.
- Drive continuous current covers about 0.83 A full load plus stall margin: acceptable; otherwise choose a drive with more current.
- Reversing relays in the motion path: remove them. The drive reverses internally from the direction signal.
- Software encoder inputs with relay-driven motors: do not build it. Use one encoder-input servo drive per axis as the position loop.
- After any power interruption: re-reference all axes before the next cut.
Questions asked
Can a step-and-direction servo drive rated 80 V maximum run a 90 VDC gear motor?
The motor rating is not the limit; the DC bus is. A drive with an 80 V maximum input will fail if you feed it an unregulated 90 V supply. Run the adjustable supply down to roughly 75 VDC and verify the voltage at the drive terminals under load before connecting any axis. The motor simply delivers proportionally less top speed at the lower bus.
Do I still need the 24 V direction relays?
No. An encoder-input servo drive reverses the motor internally in response to the direction signal from the controller. The relays come out of the motion path entirely. Keep them only if some other function on the machine, such as a brake or an auxiliary contactor, still depends on them.
Why not let the CNC software read the encoders and switch the relays from the parallel port?
A software encoder display does not close a motor position loop, and driving reversing relays from step pulses gives you a relay chatter rate no relay is rated for. The drive's own encoder input is the loop; treat encoder-readout capability in the software as a monitoring feature, not as axis control.
What happens to position when the machine powers down?
After any power interruption, plan on re-referencing every axis to a known home or fixture position before cutting. For machines where an interruption mid-cut scrapes a part, a UPS sized for the computer and the drive logic buys an orderly stop, but it does not preserve axis position through a hard power loss.
How do I scale step pulses for the geared motor and encoder?
Divide steps per revolution of the command signal by encoder counts per revolution times any electronic gearing the drive applies, then by the gearbox ratio, to get machine travel per step. Work it through axis by axis and confirm with a dial indicator or a marked travel before trusting a G-code move.