Selecting Servo Motors and Encoders for a Plasma Table

Motors, gearboxes and drives sizing Published 9 min read

Short answer

No brand decides a plasma table axis. Size peak torque at 1.58 N·m and RMS torque at 0.59 N·m for the worked 40 kg gantry, hold the reflected inertia ratio at 5.6:1 through a 3:1 belt, and check encoder resolution at 191 counts per millimeter against the torch tolerance — then pick any motor family whose datasheet clears those numbers.

On this page
  1. Does the servo brand decide how well a plasma table cuts?
  2. How do I size peak torque and speed for the gantry?
  3. How much continuous torque does the axis need?
  4. What load-to-rotor inertia ratio should I target?
  5. How many encoder counts per millimeter does the torch need?
  6. Does the servo axis need an external encoder?
  7. Incremental or absolute feedback for a plasma table?
  8. How do I make the servo axis easy to set up and repair?
  9. How do I confirm the pick on the machine?
  10. Questions asked

No brand name decides how a plasma table axis performs — four numbers do. Size peak and continuous torque from the gantry and its motion profile, hold reflected load inertia at or below about 10:1 of rotor inertia, and make encoder counts per millimeter far finer than the torch tolerance. The worked example below carries a 40 kg gantry through each calculation and ends with the motor specification those inputs produce.

Does the servo brand decide how well a plasma table cuts? #

No. Cut quality tracks following error at the programmed feed rate, and following error follows from torque headroom, inertia ratio and encoder resolution — quantities you fix before any product family enters the decision. Brand lists compress years of shop experience, and they are worth reading once the numbers below are fixed. A rugged motor on a drive that demands manual entry of every motor constant is still tedious to commission, which is how brands earn unfair verdicts. Swapping motors one-for-one on a table whose real fault is backlash, a slipping coupling or gains set too low also changes nothing; confirm the mechanics before blaming the servo.

Five quantities decide the purchase, and each limit comes from the datasheet of the exact part:

Quantity What it decides Where the limit comes from
Peak torque at acceleration Whether the drive saturates when cornering Torque-speed curve in the motor datasheet
Continuous (RMS) torque Heating over the real cut program Continuous torque rating in the motor datasheet
Reflected inertia ratio Tuning stability and ringing at corners Rotor inertia in the datasheet against your calculation
Speed at rapid traverse Headroom against rated speed Rated speed in the motor datasheet
Encoder counts per mm Position resolution at the torch Encoder datasheet and drive scaling

How do I size peak torque and speed for the gantry? #

Peak torque is the force that accelerates the gantry plus friction, times the drive radius, divided by the reduction: T = F·r/G, and the worked example needs 1.58 N·m at the motor shaft. State the inputs first, as a calculated example:

  • Gantry mass m = 40 kg
  • Acceleration a = 4 m/s²
  • Friction and belt drag at the carriage F_f = 30 N (an estimate; measure the real machine)
  • Drive radius at the pinion or pulley r = 0.025 m
  • Belt reduction G = 3:1

Accelerating force: F = m·a + F_f = 40 kg × 4 m/s² + 30 N = 190 N. Torque at the load shaft: T = F × r = 190 N × 0.025 m = 4.75 N·m. Referred to the motor through the reduction: T_peak = 4.75 N·m ÷ 3 = 1.58 N·m, before the belt stage's own losses.

Speed: a 30 m/min rapid is 0.5 m/s, so the load shaft turns 0.5 ÷ 0.025 = 20 rad/s ≈ 191 rpm and the motor turns 3 × 191 = 573 rpm. Any small servo in the 2000 to 3000 rpm rated class clears that with headroom. The 3:1 stage itself is a sizing decision, the one walked through in sizing servo reduction for belt-driven plasma table axes.

How much continuous torque does the axis need? #

Continuous torque comes from the RMS of the duty cycle, and it must sit below the motor's continuous rating; the example's traverse cycle produces 0.59 N·m, so order at least 0.6 N·m. Use a representative cycle — accelerate 0.25 s to 1 m/s, run 2.0 s, decelerate 0.25 s, dwell 1.5 s, for a 4.0 s cycle. Torque during acceleration and deceleration is the 1.58 N·m peak; during the run it is friction only: 30 N × 0.025 m ÷ 3 = 0.25 N·m.

RMS torque = √[(1.58² × 0.5 s + 0.25² × 2.0 s) ÷ 4.0 s] = √[(1.248 + 0.125) ÷ 4] = √0.343 ≈ 0.59 N·m.

As a power cross-check, a 400 W motor at 3000 rpm implies 400 W ÷ 314 rad/s ≈ 1.27 N·m continuous, so that class covers the duty with margin — take the actual rating from the datasheet of the part you order. If a later thermal reading sits near the continuous limit through a whole program, the motor is undersized or the acceleration is set too high.

What load-to-rotor inertia ratio should I target? #

Keep reflected load inertia at or below 10:1 of rotor inertia, near 5:1 for a hard-cornering gantry; the example lands at 5.6:1 through the 3:1 belt stage and 50:1 without it. Published sizing guides commonly recommend 5:1 to 10:1 for most systems, tightening toward 2:1 or 1:1 on high-acceleration axes, and warn that past roughly 10:1 to 20:1 the load begins driving the motor. Plasma work contours constantly, so treat 10:1 as a ceiling and 5:1 as the target.

The translational load referred to the load shaft is J = m·r² = 40 kg × (0.025 m)² = 0.025 kg·m². Direct drive against a candidate rotor inertia of 5 × 10⁻⁴ kg·m² gives 0.025 ÷ 0.0005 = 50:1 — reject that motor without the reduction. The 3:1 stage divides load inertia by G²: 0.025 ÷ 9 = 2.8 × 10⁻³ kg·m², a ratio of 5.6:1 — accept. On the motor frame, hold rotor inertia at or above 2.8 × 10⁻⁴ kg·m² for the 10:1 cap, or 5.6 × 10⁻⁴ kg·m² to reach 5:1. What a mid-range ratio does to loop tuning shows up in tuning a servo axis with a 6:1 ballscrew inertia ratio.

How many encoder counts per millimeter does the torch need? #

Aim for resolution about ten times finer than the torch tolerance, as a rule of thumb; a 2500-line encoder behind the example's 3:1 belt yields 191 counts per millimeter, roughly 19 times finer than ±0.1 mm. The arithmetic: quadrature counting gives 4 × 2500 = 10,000 counts per motor revolution. Travel per motor revolution is 2π × 25 mm ÷ 3 = 52.4 mm. Counts per mm = 10,000 ÷ 52.4 ≈ 191, a position resolution of 1 ÷ 191 mm ≈ 0.005 mm.

Check the frequency too: at the 573 rpm rapid the feedback streams 573 ÷ 60 × 10,000 ≈ 95 kHz, so confirm the receiving input's rated maximum sits above that and that the encoder's output type, differential line-driver or single-ended, matches the input. For this tolerance the selection passes; a ±0.02 mm spec would leave only 3.8 times margin and would call for a finer encoder or a finer drive ratio.

Does the servo axis need an external encoder? #

No, not by default: the motor's internal feedback closes the drive's current and velocity loops, and an external encoder earns its place only when position must be measured after the reduction or gearbox. That means a belt or gear stage whose backlash you want the position loop to see, wired into a drive that supports dual-loop control or into the controller as its position reference. An external encoder that nothing reads adds cost and a failure point and nothing else. When you do add one, the same output-type and frequency checks from the resolution section apply, and the placement trade-offs are the ones covered in mounting a motor encoder behind a belt reduction.

Incremental or absolute feedback for a plasma table? #

Either feedback cuts the same parts: choose absolute when the table must recover position after a power loss without a homing pass, and incremental with home switches when that pass is acceptable. Absolute feedback knows shaft angle at power-up, so a production table restarted mid-shift saves the homing cycle on X and Y; incremental feedback needs limit or home switches and a homing routine, acceptable on a low-duty machine. Absolute saves the pass only if nothing moved the gantry while the drive was off, so keep the home and limit sensors regardless. Confirm the drive supports the motor's exact feedback protocol before ordering — a protocol mismatch is the most common commissioning stall.

How do I make the servo axis easy to set up and repair? #

Setup ease lives in the matched drive, motor and commissioning software package: auto-recognition of the motor, one interface your plasma controller supports natively, and a parameter backup you have actually tested. Auto-recognition or a stored motor database replaces the manual parameter entry behind most tedious-to-program complaints. On the interface, pulse-and-direction is the simplest to commission but returns little diagnostic detail, while a networked fieldbus gives parameter access and diagnostics at the cost of configuration — choose whichever the controller supports natively, and only that one. For repair, a spare-drive swap should need nothing more than a parameter restore, so verify you can back up and reload the drive's parameters before the machine ships.

How do I confirm the pick on the machine? #

Commission with the load freed, then confirm four numbers on the loaded axis: measured travel per commanded move, peak following error at cut feed, gantry skew across the rails, and drive thermal load over a worst-case program.

  1. With the gantry freed, enable the drive and confirm rotation direction and feedback polarity match the controller's positive direction.
  2. Load the motor and feedback data, or select the motor from the drive's database, and set the current limit to the motor's rating.
  3. Run the autotune with the load attached, raising gain from low until the move is fast with no audible ringing.
  4. Set the scaling and command 1000 mm: expect about 191,000 counts at 191 counts per mm, and verify the physical travel with a scale.
  5. Set following-error and travel limits, and before the first torch-on cut verify that the emergency stop removes drive enable and leaves any Z brake engaged, per the machine's risk assessment.
  6. Trace commanded against actual position on a small-radius circle at cut feed: peak following error under about 0.05 mm — roughly 10 counts — for the ±0.1 mm example, with the fault threshold set a few times higher.
  7. On a dual-motor gantry, run both sides as one synchronized axis and measure skew across the rail spacing; hold it under about 0.05 mm at this tolerance.
  8. Read the drive's thermal load through a worst-case program; a value sustained near the continuous limit means an undersized motor or excessive acceleration.
  9. Close with a return-to-start drift check: an offset points to lost counts, a slipping coupling, or noise on the feedback lines. Route encoder cable away from the torch leads and drive power, terminate the shield as the encoder's instructions specify, and treat a cut that wanders only while the arc is lit as a wiring fault, not a tuning one.

No servo gain recovers mechanical error: rail alignment, belt tension and screw lead accuracy set the ceiling, which is why ballscrew fit and lead accuracy decide mill retrofit value on screw-driven machines. For the stated inputs — 40 kg gantry, 4 m/s², 3:1 belt, ±0.1 mm spec — the order reads:

Order requirement Example value Basis
Peak torque ≥ 1.6 N·m Calculated: 190 N × 0.025 m ÷ 3
Continuous torque ≥ 0.6 N·m Calculated: 0.59 N·m RMS over the 4 s cycle
Rotor inertia ≥ 2.8 × 10⁻⁴ kg·m² 10:1 cap; 5.6 × 10⁻⁴ kg·m² reaches 5:1
Rated speed Any 2000 rpm class or faster 573 rpm needed at rapid
Feedback 2500-line or finer, protocol the drive reads 191 counts per mm, 0.005 mm resolution

Any servo family whose datasheet clears that table does the job; after these numbers, brand is a support and availability decision, not a performance one.

Questions asked

How do I convert motor speed into table travel speed?

Multiply motor rpm by the load travel per motor revolution. In the worked drive, one motor revolution moves the gantry 2π × 25 mm ÷ 3 = 52.4 mm, so 573 rpm gives 573 × 0.0524 m ≈ 30 m/min of rapid traverse. Run the calculation backwards from your required rapid to check a motor's rated speed before you order.

What if my gantry weighs 80 kg instead of 40 kg?

Torque and inertia scale with mass. At 80 kg the example needs about 3.16 N·m peak, 1.17 N·m RMS, and the reflected inertia rises to about 5.6 × 10⁻³ kg·m², an 11:1 ratio on the same motor, past the 10:1 guideline. Move up one motor frame or deepen the belt stage to 4:1 rather than fighting the tuning.

Can one motor drive both sides of a dual-drive gantry?

You can use one motor with a mechanical cross-shaft, or two motors with two drives synchronized by the controller as one axis. Dual-drive lets the controller correct skew electrically and drops the cross-shaft, at the cost of a synchronization check at commissioning — for a cutting table it is the usual choice.

Why does the cut wander only while the plasma arc is lit?

That pattern points to arc noise coupling into feedback wiring, not to tuning. Route the encoder cable away from the torch leads and drive power, use shielded twisted pair with the shield terminated as the encoder's instructions specify, and bond shields at one point. If the wander disappears after rerouting, the mechanics and gains were never the problem.

Does the torch-lifting Z axis need a motor brake?

Yes, unless the Z axis is counterbalanced. The torch assembly falls when drive power drops, and the brake holds it there. Verify the brake releases before the first commanded move and that the emergency stop leaves it engaged.

Keep reading

  • How-to

    Correcting Rack and Pinion Speed and Torque for a Gantry Retrofit

    Travel per pinion revolution is πN/DP inches, not the pitch diameter. With an 8:1 reduction and a 22-tooth DP 16 pinion, 500 ipm needs about 926 rpm per gantry motor; the DP 20 carriage at 128/22 needs about 842 rpm. Size acceleration torque from moving weight, pinion radius, reduction and efficiency before buying drives.

    Motors, gearboxes and drives sizing

  • Explainer

    Mounting a Motor Encoder Behind a Belt Reduction

    No, not for commutation: field-oriented control switches phase current against the rotor's electrical angle, which only a sensor on the motor shaft reports directly. Behind a 10:1 belt, a 4096-count encoder gives about 410 counts per motor revolution — enough counts per pole to turn a 6-pole motor, but belt lash and multiplied noise put a load-dependent error inside the current loop. Use the belt-side sensor for velocity only; commutate from the motor shaft and add an output encoder if you need load position.

    Servo and stepper motion

  • How-to

    Sizing Servo Reduction for Belt-Driven Plasma Table Axes

    A 4.000 inch pitch-diameter pulley advances 12.566 inches per revolution, so 400 ipm turns it only 31.8 rpm and a 2500 rpm servo needs about 78.5:1 total reduction. Calculate travel per revolution from pitch diameter first, then pick ratio, motor speed and pulley size together; torque, voltage caps and software limits do not change the geometry.

    Motors, gearboxes and drives sizing