Short answer

Sin/cos 1 Vpp is an analog interface: two differential sine and cosine voltages of one volt peak-to-peak that the receiver interpolates into position, not logic pulses. A, A*, B and B* are incremental channel names that do not say analog or digital, and only the ordered feedback option's connection drawing shows whether they reach the connector.

On this page
  1. The signal on the wire
  2. Interpolation, not counting
  3. Worked example: frequency and resolution
  4. Channel names do not fix the format
  5. Absolute encoders and their incremental channels
  6. Getting digital incremental signals
  7. Analog and digital incremental compared
  8. The decision for each case
  9. Confirming the interface on the bench
  10. Questions asked

Sin/cos 1 Vpp is an analog interface. The encoder puts two sine-shaped voltages on the wire — a sine and a cosine, one volt peak-to-peak — and the receiver interpolates them into position; nothing in that channel is a logic-level pulse train. Only a receiver specified for sin/cos 1 Vpp can read it. The labels A, A*, B and B* on an absolute encoder are a separate question: they name incremental channels, they do not say analog or digital, and whether they reach the connector depends on the exact feedback option you order. Digital incremental outputs exist too, as a different, explicitly specified interface. Here is how to tell the formats apart, what the numbers mean, and what to write on the order.

The signal on the wire #

Vpp means volts peak-to-peak: the difference between a waveform's maximum and its minimum. On a sin/cos encoder, channel A is a sine and channel B a cosine, displaced by 90 electrical degrees. Each travels as a differential pair, A+ with A– and B+ with B–, so the position data occupies four conductors plus supply and ground. Interface design guides for sin/cos encoders — the one from Texas Instruments among them — document the levels consistently: one volt peak-to-peak across each pair, typically riding a 2.5 V DC offset to ground.

No IEC or EN document fixes this interface; 1 Vpp sin/cos is a de facto convention that encoder and receiver makers have kept stable for decades, which is why parts from different manufacturers interoperate. What the convention requires is short: the stated amplitude on each differential pair, the quarter-cycle phase between the channels, and a receiver that measures amplitude and phase instead of looking for logic edges. The differential form is part of the deal — why a differential input rejects a single-ended 5 V encoder signal explains the noise rejection you give up without it.

Interpolation, not counting #

An analog encoder input works in two layers. Complete signal cycles give coarse position: the receiver counts them like an ordinary incremental channel. Inside the current cycle, fine position comes from the amplitude ratio of the two channels — the arctangent of A over B in the receiver's math — and subdividing a cycle this way is what interpolation means. The interpolation factor belongs to the receiver, so the same encoder yields different resolutions on different inputs.

A digital counter input does the opposite: it detects transitions between defined high and low states and counts them. Feed the sine channels into one and nothing valid happens. With the typical offset, each conductor to ground swings between roughly 2.0 V and 3.0 V — never near a logic low — so the counter sees no transitions, or random ones if a threshold happens to land inside the swing. That single fact settles the analog-or-digital question for any encoder specified as sin/cos 1 Vpp: the terminals carry analog waveforms.

Worked example: frequency and resolution #

Take an encoder with 2048 sine cycles per revolution, a maximum shaft speed of 3000 rpm, and a receiver that interpolates 100 steps per cycle. Everything below is a calculated example for those inputs, not a measured result.

Signal frequency per channel:

f = cycles per revolution × revolutions per second

f = 2048 × (3000 ÷ 60) = 2048 × 50 = 102,400 Hz, about 102.4 kHz

At full speed the receiver's analog input and the cable must pass roughly 102.4 kHz per channel without distorting it; an input specified below that frequency rules the pairing out at top speed. Resolution comes from the interpolation:

steps per revolution = 2048 × 100 = 204,800

angular step = 360° ÷ 204,800 ≈ 0.0018° per step

A digital incremental encoder with 2048 pulses per revolution, counted in quadrature ×4, delivers 2048 × 4 = 8192 counts per revolution — twenty-five times fewer from the same line count, which is one reason servo feedback uses the analog form. Its channel frequency at the same speed is likewise about 102.4 kHz, but there it is a counter-frequency requirement instead of an analog bandwidth requirement.

Channel names do not fix the format #

A and B name the two incremental channels, displaced a quarter cycle apart so the receiver takes direction from which one leads. The star marks the complementary partner: an inverted copy for differential transmission, not a third or fourth position channel. Manufacturers use this identical notation for analog sin/cos outputs and for digital TTL or HTL outputs, so the letters alone say nothing about voltages or pulse shape. The function of each pin comes from the terminal legend and electrical specification of the exact encoder option. A name match is not an interface match — the same lesson as matching encoder signal names between motor and servo drive.

Absolute encoders and their incremental channels #

Absolute describes the position data, not the electrical interface. An absolute encoder can carry incremental channels alongside its absolute-position link, and many servo-motor feedback options do exactly that — but a family brochure that lists A, A*, B and B* does not mean the option you ordered brings them to the connector. The connection drawing of the exact ordered option decides: if it shows the four terminals with a sin/cos or TTL specification, they are there; if it shows only the absolute interface, they are not. Check before the order goes in, not after delivery.

The two channels then do different jobs. The incremental pair feeds the drive's fast speed loop; the absolute link hands over position at power-up without a homing move. Real hardware combines them — one motor-feedback arrangement pairs a 1 Vpp sin/cos channel with an SSI absolute channel on one connector, and the drive must be set up for both, as shown in configuring a drive for an encoder that carries both 1 Vpp sin/cos and SSI. An axis left on incremental channels alone loses its counted position at power-off and needs a defined homing sequence at power-up; homing an incremental encoder axis without a proximity switch shows one way to build it.

Getting digital incremental signals #

Digital incremental outputs exist — just not under the sin/cos label. Their output circuits are open-collector, push-pull or differential line driver, at TTL levels around 5 V or HTL levels from a higher supply, commonly 24 V in machine control. Digital alone is not a purchasing specification: driver type, supply, logic levels, input thresholds and termination must agree with the receiver. An HTL encoder, for example, needs its supply wired correctly before any pulse can be counted — HTL incremental encoder supply terminals +Us and 0Vs covers that wiring. Whether the motor family you are ordering offers a digital incremental option at all is answered by its ordering data and the manufacturer's support; order it by the documented interface name, never by the word digital.

If the motor offers only sin/cos and the receiver only counts pulses, the bridge is an interpolating converter: a unit whose input is specified for sin/cos signals and whose output is quadrature pulses at the counter's logic levels. Its interpolation factor sets the output frequency, so repeat the worked example above with that factor and compare against the counter's specified maximum. The conversion adds a small latency of its own — real, and worth knowing in a tight position loop, though rarely the limiting term.

Analog and digital incremental compared #

Aspect Sin/cos 1 Vpp Digital incremental
Signal on the wire Continuous sine and cosine voltages, 90 electrical degrees apart Pulse trains between defined high and low levels
What the receiver does Measures amplitude and phase, interpolates within each cycle Detects transitions and counts them
Levels 1 Vpp across each differential pair, typically on a 2.5 V offset TTL or HTL logic levels
Resolution comes from Cycles per revolution × receiver interpolation Pulses per revolution × counting mode (×1, ×2, ×4)
Speed limit set by Analog bandwidth of receiver and cable at the signal frequency Counter frequency at the pulse frequency

The decision for each case #

  • The receiver has a sin/cos input and the motor offers sin/cos: order that option; it is the standard match. Check the receiver's bandwidth against the signal frequency at maximum speed, as in the worked example.
  • The receiver only counts pulses: order a digital incremental option documented for the receiver's levels and driver type, or keep sin/cos and add a specified converter.
  • You need position at power-up without homing: order an absolute channel and verify the drive implements that protocol — how to verify a servo drive supports EnDat 2.1 encoder feedback shows the check for one protocol.
  • You need the incremental pair from an absolute encoder: confirm the four terminals on the ordered option's connection drawing before the order goes in.

Write the requirement in electrical terms — analog sine/cosine at 1 Vpp, differential, or digital differential quadrature at TTL levels — and keep the option designation, connector identification and receiver input type on one line of the order.

Confirming the interface on the bench #

On a received motor, a two-channel oscilloscope settles the question in minutes. Power the drive down and lock the machine out, and open the feedback connector rather than probing it live — the plug usually sits beside the motor power leads. Supply the encoder from a 5 V source within its datasheet range, probe A+ to ground on one channel and B+ to ground on the other, and turn the shaft by hand. Analog feedback shows two clean sinusoids a quarter cycle apart; TTL incremental shows square corners. Subtracting the pair with channel math, A+ minus A–, reads the rated peak-to-peak amplitude directly.

Questions asked

Can a PLC read sin/cos 1 Vpp feedback at all?

Yes, but not through its ordinary counter inputs. PLC manufacturers offer interpolating encoder input modules for their bus systems: the module does the analog interpolation in hardware and hands the controller a position value. The module's interpolation factor and maximum input frequency set your resolution and speed limits, so treat the module, not the PLC, as the receiver when you check the numbers.

Does 1 Vpp mean the encoder runs on a 1 V supply?

No. The 1 Vpp figure describes the output amplitude: one volt peak-to-peak across each differential pair. The encoder itself is typically supplied from 5 V DC, which is also the supply most interpolating inputs feed out to the encoder. Take the supply range and current draw from the encoder's datasheet before powering it from a drive or a bench supply.

How do I tell from a connection drawing whether the incremental channels are analog or digital?

Look past the pin names to the electrical column or the output specification the drawing references. An analog entry states an amplitude and an offset; a digital entry states logic levels and a pulse count, for example TTL at 2500 pulses per revolution. If the drawing assigns those pins to a protocol such as SSI or EnDat instead, they carry no incremental signal at all.

Can I leave A* and B* unconnected and read only A and B?

Rarely with this interface. A single conductor carries only a small swing around the offset, far from full logic levels, so few inputs accept it, and dropping the complement forfeits the differential pair's noise rejection. Wire all four conductors into a receiver with true differential inputs. Single-ended connections suit TTL encoders with full-swing outputs, and even there they are the weaker option.

Is an absolute encoder's SSI or EnDat link something an incremental input could count?

No. SSI and EnDat are digital, but they are serial position-data links: the receiver clocks the encoder and receives an absolute position word, not a pulse train. A counter input cannot read them, and a drive needs the matching protocol port. That is why digital is not a sufficient requirement: name the pulse format or the protocol, then verify the receiver implements it.

Keep reading

  • How-to

    Matching Encoder Signal Names Between Motor and Servo Drive

    Matching capability labels do not prove a motor and drive will talk. Map the sine and cosine pairs by function, then resolve index, data and clock and the commutation definition from both datasheets into a function-based cable schedule, because the connectors will not match pin for pin.

    Sensors, encoders and machine vision on the machine

  • How-to

    How to Verify a Servo Drive Supports EnDat 2.1 Encoder Feedback

    No, a drive that accepts 1 Vpp Sin/Cos analog feedback has not demonstrated EnDat 2.1 support, because EnDat is a separate clocked, bidirectional digital protocol sharing the same cable. Before wiring, confirm the released feedback documentation and firmware release notes for the exact drive model list EnDat 2.1, including the 1 Vpp commutation signals when the motor order code shows them. Size the drive from the motor's current profile over the duty cycle, since a peak-current figure for another model line establishes neither continuous rating nor overload duration.

    Sensors, encoders and machine vision on the machine

  • How-to

    Capturing Serial Absolute Encoder Data at Machine Startup

    A terminal board cannot read an absolute encoder's startup position until the amplifier's own interface document pins down the levels, the master, the request/reply timing and the framing. Verify those, decode one axis, validate it against a known move, then replicate the channel to all four axes.

    Sensors, encoders and machine vision on the machine