How-to
Matching Encoder Signal Names Between Motor and Servo Drive
Short answer
Matching capability labels do not prove a motor and drive will talk. Map the sine and cosine pairs by function, then resolve index, data and clock and the commutation definition from both datasheets into a function-based cable schedule, because the connectors will not match pin for pin.
On this page
When a servo motor and a servo drive come from different makers, the encoder interface decides whether the pairing works. Matching capability labels, with both sides saying multiturn absolute and both saying sin/cos, prove nothing about the wires, and the connectors will not match pin for pin. What works is a function-based signal schedule: the motor's sine pair meets the drive's sine input whatever each side calls it, the index question is settled from both manuals, and the drive's commutation label is pinned to a physical encoder line before anyone makes a cable. Here is the name-to-function map, the procedure, the conductor count for a typical sin/cos interface, and the bench checks that close it out.
What the signal names mean #
A sin/cos feedback device outputs two analog tracks in quadrature: a sine on one differential pair and a cosine on another, each nominally 1 volt peak-to-peak (1 Vpp). The drive interpolates between the waveform crossings, which is how an analog track resolves finer position than edge-counting alone. Most servo encoders of this type add a serial channel for absolute and multiturn data, and on many of them the once-per-revolution marker travels inside that data stream rather than on its own pair.
| Function | Names you will meet | What it carries |
|---|---|---|
| Sine track | A+/A-, SIN+/SIN- | 1 Vpp analog sine, differential |
| Cosine track | B+/B-, COS+/COS- | 1 Vpp analog cosine, in quadrature with the sine |
| Once-per-revolution marker | I+/I-, index, marker | Reference pulse for homing and turn counting |
| Absolute data | DATA+/DATA- | Position and multiturn bits; often carries the marker |
| Data timing | CLOCK+/CLOCK- | Times the serial data transfer |
| Rotor position for commutation | commutation channel label, dedicated second track (one maker calls it Z1) | Tells the drive where the motor poles are |
The last row is where cross-brand pairings go wrong. One manual calls its rotor-position input a commutation channel; one encoder puts that information on a dedicated second track; another puts it in the serial data stream. Same function, three possible homes, and only the pin tables of the two documents in your hands say which one your parts use.
Why the connectors will not match pin for pin #
Different makers choose different shells, pin counts and pin orders for the same functions, so a cable wired pin 1 to pin 1 moves whatever each maker happened to put on each number, including supply rails. Capability words do not help: multiturn absolute names a class of encoder, not a wiring standard, and sin/cos names an analog signal format, not a pinout. The function lists may not even be one-to-one, because a drive can expect a discrete index pair while the encoder outputs its marker only inside the data stream.
If the drive's feedback input turns out to be a resolver type rather than an encoder type, this mapping exercise is the wrong one; selecting a replacement servo drive for resolver motors is the path that applies instead.
How to build the signal schedule #
- Record the exact devices: the full drive model with its feedback option, and the motor's exact encoder option code. Multiturn absolute alone does not define an interface. If the motor's feedback type is undocumented, identify it first — how to identify geared resolver and encoder feedback on old servos covers the checks you can make with the motor on the bench.
- List the drive's required inputs from its feedback chapter: every channel name and polarity, the electrical format it accepts (1 Vpp analog or square wave), the supply it delivers to the encoder, and any cable length limit it states.
- List the encoder's outputs from the motor documentation, in the same columns.
- Map the analog pairs by function: sine pair to sine input, cosine to cosine, + to + and - to - through the cable. Function decides, not pin number.
- Resolve the index. If the drive has discrete I+/I- inputs, its manual must state that a marker delivered inside the serial data satisfies them; if the drive accepts only a discrete pair and the encoder outputs none, the pairing stops on that single line.
- Resolve the commutation label against the encoder's physical lines, dedicated track or serial pair, from both pin tables. Name similarity is not a mapping.
- Close the schedule: every drive input has exactly one encoder source, and the electrical formats agree. One unresolved row is a stop condition, not a guess to wire through.
- Build the cable from the schedule and bench-check it before the first coupled move.
Worked example: conductor count for a sin/cos encoder with data and clock #
The case: a motor whose sin/cos encoder sends its marker and multiturn data out on a serial data and clock pair, mated to a drive that lists A and B inputs, I+/I- index inputs, and a commutation channel input.
Inputs, each with its basis:
- Sine pair, A+ and A-: 2 conductors — the analog format defines one differential pair per track.
- Cosine pair, B+ and B-: 2 conductors — same basis.
- Data pair, DATA+ and DATA-: 2 conductors — the motor's encoder documentation.
- Clock pair, CLOCK+ and CLOCK-: 2 conductors — same source.
- Supply pair, +V and 0 V: 2 conductors — voltage from the motor's encoder documentation.
- Shield: 1 conductor.
Rule in words: every differential signal takes two wires, the supply takes two, and the shield adds one; the cable's conductor count is the sum.
Arithmetic: 4 signal pairs x 2 conductors = 8; 1 supply pair x 2 = 2; 8 + 2 = 10 conductors; 10 + 1 shield = 11.
Result: 11 conductors, 10 signal and supply wires plus the shield, with the drive's index inputs served from the data pair if, and only if, its manual documents marker-from-stream.
Decision: below 10 conductors plus shield the cable cannot close this schedule, so a 9-conductor cable fails it, and doubling functions onto shared wires is not an option. If a discrete index pair were also required, add 2 and the count becomes 13. If the drive's manual does not document marker-from-stream, the count is irrelevant: the pairing fails on documentation, not on copper.
Bench checks before the first coupled move #
Back-drive the motor by hand and scope each analog pair from + to -: two clean sinusoids in quadrature. With the drive powering the encoder, the data and clock lines should show activity when the drive interrogates it.
Drive power off and the DC bus discharged before you mate or unmate feedback connectors. Run the first motion test with the load uncoupled and the axis guarded, with the infeed protected by a motor circuit breaker on a servo drive infeed.
The deliverable of all this is one page: a schedule in which every drive input names its encoder source. When the page is full, commit to the pairing; when one row is empty, stop, because that row is the difference between a working cross-brand pairing and a damaged input stage.
Questions asked
Can a drive that accepts multiturn absolute encoders run any multiturn absolute motor?
Not on the strength of the label. Multiturn absolute names a capability class, and the serial format, marker handling and commutation definition are all fixed at option level. Get the pin-table document for the exact drive feedback option and the exact motor encoder option before making anything. If either document stops short of a pin table, the pairing is unproven and stays at the schedule stage.
What do A+, A-, B+ and B- carry on a sin/cos encoder?
Two analog tracks in quadrature: A is the sine and B the cosine, each nominally 1 Vpp on a differential pair. Because both waveforms are continuous, the drive interpolates their crossings rather than only counting edges, which is how analog feedback resolves finer position than a square-wave encoder of the same track count. Keep each pair and its polarity intact through the cable or the interpolation fails.
Is the drive's commutation channel the same as the encoder's data and clock lines?
Sometimes, and that is the trap: the name belongs to the drive maker, not the encoder. On sin/cos encoders the rotor-position information may sit on a dedicated second commutation track or inside the serial data stream. Only the pin tables of both documents, matched function by function, tell you which physical pair serves that input.
What if the drive's incremental input accepts square-wave signals only?
Then the pairing ends there. The analog tracks need an input specified for 1 Vpp differential signals; a square-wave input has edges to count and nothing to interpolate. It is the cheapest mismatch to find and the most expensive to discover after the cable is made, which is why the electrical format belongs in the schedule before any pin is assigned.