How-to
Sizing Timing Belt Preload for a High-Torque Servo Joint
Short answer
Preload each belt side to at least half the peak tangential force F = T/r at the servo pulley — 462 N per side for 5.88 N·m on a 20-tooth GT2 pulley — and never above the lower of the belt's rated tension and half the output bearing's radial rating. At that torque, narrow GT2 stock falls below the minimum, so the belt stage needs less torque or a higher-rated belt. Verify with T = 4·m·L²·f².
On this page
A timing belt joint holds zero backlash only while the slack side stays in tension at peak torque. Set the preload per side, T0, to at least half the peak tangential belt force F = T/r — the torque at the servo pulley divided by that pulley's pitch radius — and below the lower of the belt's rated working tension and half the output bearing's radial limit, because two spans pull each shaft with about 2·T0. For 5.88 N·m on a 20-tooth GT2 pulley that minimum is 462 N per side, which narrow GT2 stock is not rated to carry; the arithmetic below shows when the design has to change. Whatever you set, verify it by span frequency, T = 4·m·L²·f² — the same stage sized end to end is covered in sizing the servo and GT2 belt stage for a 6DOF arm.
The tension window #
At rest, both spans carry the preload T0. Under torque the tight side rises to T0 + F/2 and the slack side falls to T0 − F/2, so the two always sum to 2·T0 — the identity every belt-tension method is built on. When the slack side reaches zero, its teeth unload, the belt can climb and jump teeth at load reversal, and the joint has a dead zone no servo tuning removes.
The minimum preload per side is therefore F/2, computed at the peak torque the drive can actually command: the stall or current-limit value, including acceleration at the worst arm pose — not the continuous figure in the sales line.
The ceiling comes from two places. The belt's allowable working tension, from its datasheet, caps preload directly. The shafts feel about 2·T0 of radial load from the two parallel spans, so the output bearing's radial rating caps T0 at half of itself. Run at the bottom of a valid window, never the top.
Worked example: 5.88 N·m on a 20-tooth GT2 pulley #
Inputs, all assumed for this calculated example: a serial servo listed at 60 kg·cm, which is 60 × 0.0981 N·m = 5.88 N·m at stall (confirm rated versus stall on the datasheet; stall governs); an assumed 20-tooth GT2 pulley, GT2 pitch being 2 mm.
- Pitch diameter: 20 × 2 mm ÷ π = 12.73 mm, so r = 6.366 mm = 0.006366 m
- Tangential force: F = 5.88 N·m ÷ 0.006366 m = 924 N
- Minimum preload per side: F ÷ 2 = 462 N
- Radial load on the servo shaft at that preload: 2 × 462 N = 924 N
Every figure above is calculated from those inputs, not measured. The force sits entirely at the servo pulley: if this belt drives a larger joint pulley, the torque multiplication happens after the belt and does not relieve it.
The two ceilings above that minimum #
Published figures for small-pitch GT2 belt stock put allowable working tension near 111 N (25 lbf) per 25.4 mm of width — about 26 N for a 6 mm belt and 39 N for the 9 mm width that listing tops out at. The same class of listing rates breaking strength at 86 N per 1 mm of width, so 516 N for a 6 mm belt. Rubber, glass-cord power-transmission belts publish much higher allowable figures; take the number from the datasheet of your exact belt and width before trusting any of this.
The bearing side is often the blank: many serial servos publish no radial rating for the output shaft. Get it from the maker, or treat that bearing as the life-limiting part and keep 2·T0 as low as the window allows.
Decision for this joint #
The window from 462 N down to 26 N is empty, so a 20-tooth GT2 stage cannot be tensioned to zero slack at 5.88 N·m within the published ratings — 462 N per side is also about 90% of that stock's 516 N breaking figure. The committed options:
- Bigger servo pulley. F scales as 1/r, so a 40-tooth pulley (r = 12.73 mm) drops F to 462 N and the minimum preload to 231 N. Necessary, not sufficient: still above both ceilings.
- Less torque at the belt. Bringing F/2 down to the published allowable takes roughly 18:1 of reduction behind 6 mm stock or 12:1 behind 9 mm. With margin, 15:1 and a 9 mm belt puts the belt at 0.392 N·m, F = 62 N, and a real window of 31–39 N per side; set 35 N. Whether that final stage should be a belt at all is the question answered in belt or gearbox reduction for a stepper robot arm.
- A higher-rated belt family, sized from a drive-design manual's rating tables rather than hobby-stock listings. If the belt is the part that changes, selecting a timing belt rated above the target preload is where that starts.
Running the 20-tooth stage at 462 N per side anyway is a decision to operate above published ratings: it stays lash-free until a collision makes it jump teeth, and its life is unverified. Measure it as described below, or change the design.
Setting the preload step by step #
- Collect from datasheets: stall or current-limit torque; pulley tooth counts and pitch; belt width, allowable working tension and mass per length; output-bearing radial rating.
- Compute F = T/r at the servo pulley with peak torque; the minimum preload per side is F/2.
- Compute the ceiling as the lower of the belt's allowable tension and half the bearing's radial rating. If F/2 exceeds it, stop and change the design as above.
- Build in adjustment and a lock: a slotted motor mount or an eccentric idler, then hardware that fixes center distance. Never tension by twisting the servo case or loading its output horn.
- De-energize the machine and support the arm before touching the belt — a tensioned span and a loaded joint release stored energy, and the arm falls when the joint is freed.
- Set tension near the bottom of the window, verify by span frequency, and record that frequency as the baseline.
- Set the joint's bearing preload separately, with the belt off: remove axial play, back off until the joint turns freely, refit the belt and confirm the free-turning torque did not rise. If it rose, belt tension is bending shafts or mounts.
- Run a reversal test under load, logging joint angle against command in both directions.
- Re-check the span frequency after break-in, then at the interval you set below.
Verifying the set tension by span frequency #
Pluck the free span like a guitar string and read the lowest peak on a spectrum app — the fundamental, not a harmonic. Tension follows T = 4·m·L²·f², with m the belt's mass per length and L the free span between tangent points.
Calculated check for the redesigned 9 mm stage above, with m assumed at 0.020 kg/m (replace with your datasheet value) and L = 0.200 m: a target of 35 N needs f = √(35 ÷ (4 × 0.020 × 0.200²)) = √(35 ÷ 0.0032) = 105 Hz. Read back, 105 Hz gives T = 4 × 0.020 × 0.0400 × 105² = 35.3 N, which closes the loop on the setting.
The force-gauge alternative is the deflection method: push the span at mid-point by span ÷ 64 — 3.1 mm on a 200 mm span — and compare the gauge reading with the belt maker's table for that deflection.
Lash, wind-up and the feedback loop #
Read the reversal test by shape. A dead zone at reversal is lash: slack-side collapse or tooth clearance in the mesh. A slope that returns to zero is wind-up: span elasticity under torque. The fixes are different — lash wants more preload or a higher-rated belt, wind-up wants a shorter span or a wider belt; adding tension to cure wind-up only loads the bearing.
Center distance moves both. A longer span lowers stiffness, raises wind-up at the same torque, and drops the span's natural frequency, which is why two center distances give visibly different results on the same arm. An idler that shortens the free span fixes buzz and wind-up together.
Where the encoder sits decides what the servo can see. Its internal sensor reads the motor shaft, so wind-up and lash land outside the feedback loop; the arrangements are compared in mounting the motor encoder behind a belt reduction. When joint accuracy matters, close the loop on the joint output shaft.
Life, re-tensioning and heat #
No published cycle life covers this duty; set your own acceptance from the position-error budget, record the baseline frequency, and re-measure at fixed cycle counts you choose. Retension when either the error or the frequency crosses its limit. Tension scales with frequency squared, so frequency is the more sensitive indicator.
Frequency that keeps falling after break-in means the center distance is not locked, a set-screw pulley without a shaft flat is walking, or the belt is running above its rating. And a servo case that runs warm with the belt on but not with it off is reporting radial load from over-tension, not a drive fault.
Questions asked
Should I size the preload from rated torque or stall torque?
From the highest torque the drive can command, which is the stall or current-limit value. A servo listed at 60 kg·cm delivers about 5.88 N·m only near stall, and collisions and hard holds get there. Slack-side collapse is decided at that peak, so compute F = T/r with it; rated continuous torque only sets the thermal duty.
The belt span buzzes at certain speeds — is the tension wrong?
Buzz means something in the motion is exciting the span near its natural frequency. Re-check tension first, but the lasting fixes are a shorter span, an idler that splits it, or a wider belt. Adding tension to kill buzz loads the output bearing for no accuracy gain.
My GT2 belt's rated tension is below F/2 — what do I change first?
Do it on paper: doubling the pulley's pitch radius halves F, so a 40-tooth pulley takes 924 N down to 462 N and the preload minimum to 231 N. If that is still above the belt's rating, the real fix is reduction ahead of the belt or a power-rated belt family sized from a drive-design manual.
How do I know when to re-tension?
Set the trigger yourself: log the span frequency at assembly, re-check after the first run-in interval, then at fixed cycle counts against your position-error limit. Because tension scales with frequency squared, a 10% drop in measured frequency is a 19% loss of tension — retension at that point, not when lash becomes visible.
Can I check tension with a force gauge instead of frequency?
Yes, with two limits the frequency method does not have. Push the span at mid-point to a deflection of span divided by 64 — 3.1 mm on a 200 mm span — and compare with the belt maker's table, but if an idler splits the span you must gauge each free span separately, and on short spans where that deflection is under a couple of millimetres the reading gets coarse. The frequency method reaches the same tension without a table, using only belt mass per length from the datasheet.