Explainer
Step and Direction to a ±10V Servo Drive: What Converts It
Short answer
No: a step-and-direction stream cannot be wired to a ±10 V analog servo input, because pulses count position while the analog input reads a voltage as a torque or speed level. A motion controller or pulse-to-analog converter that counts the pulses, closes the position loop from encoder feedback and outputs the scaled voltage does the conversion; the drive's digital terminals are enable and fault I/O, not a command path.

On this page
- Can step and direction pulses drive an analog servo input directly?
- What are the 24V digital terminals on the drive for?
- What hardware converts step and direction into an analog servo command?
- How do you scale the analog output to the drive's torque span?
- What if the drive also accepts step and direction directly?
- How do you commission a pulse-to-analog servo axis safely?
- Questions asked
A step-and-direction pulse stream cannot drive a ±10 V analog servo input, and no adapter cable changes that. The pulse stream encodes position as a count of discrete increments; the analog input reads a continuous voltage as a level of torque or speed. The conversion is real hardware: a motion controller or pulse-to-analog converter that counts the incoming pulses, closes the position loop from encoder feedback, and outputs the scaled voltage the drive's command mode expects. The drive's digital terminals are enable and fault signaling — permission to apply torque, never a command to move. On a drive whose manual lists only that digital I/O and an analog torque input, the decision is already made: you need the converting controller, wired so the enable circuit stays separate from the analog command path.
Can step and direction pulses drive an analog servo input directly? #
No: a step pulse commands one discrete increment of motion while the analog input continuously interprets the voltage present at that instant as a fraction of rated torque or speed, so connecting one to the other converts nothing.
A step-and-direction interface is read by a counter: pulse edges add increments, the direction level sets the sign, and the receiver's job ends there. An analog command input is read by a scaling circuit that feeds the drive's control loop continuously. Wire a pulse train into the analog input and the drive sees whatever its input filtering averages the train to: a 50% duty-cycle train sits near zero and reads as no command, a burst of pulses reads as a torque spike, and a line held high reads as a full-scale demand — which on a torque input means the drive applies everything it has, instantly. This is not merely a wiring that fails to work; it is a wiring that can command full torque by accident.
What are the 24V digital terminals on the drive for? #
They are the drive's digital input and output — drive-enable in, fault and status out — and an enable level gives the drive permission to apply torque without ever telling it how far to move or how hard to push.
The trap is voltage similarity. A ±24 V opto-isolated I/O rating names the isolation hardware and the enable circuit's electrical interface, not a command format, so terminals that share a voltage level with your controller's outputs are still just enable and fault wiring. Feed pulses into an enable input and one of two things happens: pulses too small to cross the input's switching threshold do nothing, or pulses that do cross it switch enable on and off at pulse rate while the command input stays at zero — no torque either way. Enable is a gate, and gating a zero command yields zero motion.
What hardware converts step and direction into an analog servo command? #
Two devices do it: a motion controller with a native analog output, or a dedicated pulse-to-analog servo converter, and both count the incoming pulses, compare that commanded position with the motor's encoder feedback, and turn the following error into the scaled analog voltage the drive's command mode expects.
The drive side matters here: in torque mode the drive regulates motor current only, so the position loop must live in the converter or controller. That loop is what conversion hardware adds, and it is why a power supply set to a fixed voltage is not a converter — with no loop, a fixed voltage is a fixed torque, and the axis runs away or stalls against the load.
Four checks decide whether a converter fits. The pulse input must be rated for a maximum frequency at or above the controller's peak step rate — a controller emitting 40,000 steps/s at top feedrate needs an input specified for at least that — and inputs that poll or filter too aggressively drop short pulses, the failure described in why inputs miss short pulses and how to catch them. The encoder input must accept the signal type and level the motor's feedback produces, which is the same electrical problem as wiring a TTL quadrature encoder to drive encoder terminals. The analog output must span the drive's full command range with configurable polarity, and the converter needs digital I/O for the enable and fault circuit, because that wiring stays in the picture whatever converts the command.
If you are specifying hardware from scratch rather than adapting drives you already have, matching the controller's output to the drive's command mode is the entire selection problem, and finding a servo drive that accepts an analog command works through that choice on the drive side.
How do you scale the analog output to the drive's torque span? #
Match the converter's full-scale output to the drive's full-scale command span and the mapping is linear: in the worked example below, a demand of 30% of rated torque becomes 3.0 V, because 30% of the 10 V full-scale span is 0.30 × 10 V = 3.0 V.
The example inputs, chosen for illustration:
- Analog command span: the drive accepts a ±10 V torque command and, in this example's assumption, maps it to ±100% of rated torque. Real spans are set in each drive's analog-input scaling parameters and differ between drives — take the actual span from there.
- Motor rating: 8 N·m (example value).
- Acceleration demand: 2.4 N·m, the figure a load and inertia sizing run produced (example value).
The arithmetic: 2.4 N·m ÷ 8 N·m = 0.30, so the demand is 30% of rating, and 0.30 × 10 V = 3.0 V, positive for forward and negative for reverse with the sign convention set by the drive's polarity parameter. This is a calculated example for these inputs, not a measured result: change the span mapping or the motor rating and the command voltage moves with them.
In a running axis you never set that voltage by hand — the position loop produces it, and the scaling above is what you configure so the loop's full output authority lands exactly on the drive's rated span. Scaled too low, the axis is sluggish; scaled too high, the loop is overdriven, noisy and quick to fault on small errors.
What if the drive also accepts step and direction directly? #
Then skip the converter entirely: wire the controller to the drive's pulse and direction terminals and set the scaling in counts per unit, exactly as on any drive that natively takes pulses, because the command-mode list in the drive manual decides this, not the voltage ratings on the terminals.
Many industrial drives offer both interfaces in one unit, selectable by parameter, and some amplifier families document an analog or PWM-and-direction command instead. If the manual's mode list includes pulses, set the drive's counts-per-unit scaling so that one commanded unit equals one real unit of motion — the arithmetic in calculating step and direction servo pulses per unit carries over unchanged. If the list shows only an analog command, as with the surplus drives that raise this question, the converting controller is the path.
One more decision case: a manual that documents neither an analog command nor a pulse command describes an unknown interface, and a shared voltage level is not evidence of a shared command format. The manufacturer's documentation is the only source for what that drive accepts.
How do you commission a pulse-to-analog servo axis safely? #
Bring the axis up in stages with the motor uncoupled and the mechanism clear: verify every terminal with power isolated, enable with zero command, jog at low command and confirm direction, and only then run a measured move.
Work the sequence in this order:
- With power off and locked out, trace every terminal against both manuals: pulse, direction, the analog pair and its signal reference, enable, fault. Keep the enable circuit's wiring separate from the analog command pair.
- Set the drive to its documented analog command mode, and configure the converter's output span and polarity to the drive's range.
- Enable the drive with the command input at zero: the shaft must sit still with no drift, proving the enable circuit gates torque rather than commanding it.
- Command a small positive level, then a small negative level, and compare commanded direction with observed shaft direction; a meter across the analog pair confirms the converter's output tracks the pulse stream.
- Run a short measured move uncoupled, repeat it with the load coupled, then exercise enable-off and fault response in the sequence the drive documents.
If the analog command is present and correct in polarity and magnitude but the drive will not respond, the cause is downstream of the converter: command mode, enable state or an active fault. If the command is absent or wrong, work back from the analog pair through the converter configuration and the pulse wiring.
Unexpected shaft rotation is the hazard in this work, so keep hands, tools and loose clothing clear during every test and follow the machine's lockout practice between them; this procedure verifies the command interface and is not a substitute for the machine's risk assessment and guarding.
Questions asked
Can I feed the step pulses into the drive's 24 V enable input instead?
No. Enable is a permission level, not a motion command: with permission active the drive still produces torque only in proportion to its command input, which stays at zero. A 5 V logic pulse may not cross a 24 V input's switching threshold at all, and if it does, the drive switches enable on and off at pulse rate while the commanded torque never leaves zero.
Does full-scale analog voltage always mean 100% of rated torque?
No. The mapping is set per drive in its analog-input scaling parameters: one drive spans rated torque at full scale, another spans a multiple of it, and a drive configured for velocity mode maps the same range to speed instead. Read the span and offset for your exact model and set the converter's output scale to match it before running.
Can I build the conversion myself with a microcontroller?
It is possible in principle: count pulses, decode the encoder, run a position loop and drive a digital-to-analog output. But you would be building a real-time motion controller, with pulse rates that can exceed 100 kHz, encoder edge rates to match, loop tuning, and enable and fault handling to design and prove. Existing converters and controllers already do this; a custom build is a development project, not a drop-in part.
Why does the axis lose position at high feedrate after converting?
Usually lost pulses. Every step the converter fails to register is a distance increment the position loop never sees, so the commanded position falls behind and the loop pulls the motor back off the path; the symptom grows with feedrate. Check that the converter's rated maximum input frequency exceeds the controller's peak step rate, and that the pulse wiring and its shielding meet the edge-speed requirements of both manuals.