Selection guide
Stepper Motor Resolution: Microstepping Versus a Gearbox
Short answer
Past about x20 microstep divisions, commanded microsteps are finer than a stepper's ±5 percent full-step accuracy, so the extra counts stop being positions the shaft repeats. Put the multiplication in a gearbox: a 10:1 gearhead with the drive at x10 multiplies counts and torque while dividing reflected inertia by the ratio squared, at the cost of backlash and a higher pulse rate.

On this page
Past about x20 microstep divisions, each commanded microstep is smaller than a stepper motor's own mechanical error, so the extra counts stop being positions the shaft repeats. Microstepping alone is dependable to roughly 10,000 counts per revolution on a standard 200 full-step motor; past that ceiling, put the multiplication in a gearbox. A 10:1 gearhead with the drive set to x10 resolves more at the output than x50 alone, keeps every commanded increment larger than the error band, multiplies torque by its ratio times its efficiency, and divides reflected load inertia by the ratio squared. The costs are backlash, efficiency and a pulse rate that scales with the ratio. The arithmetic below shows where each route wins, and the closing section commits to a decision for each requirement.
What microstepping buys, and what it does not #
Microstepping proportions the current in the motor's two phases so each full step is split into m commanded increments; resolution rises from 200 to 200 × m counts per revolution. On a standard hybrid motor the full step is 1.8°, so a drive set to x50 resolves 10,000 counts per revolution. Manufacturer documentation puts positioning accuracy at about ±5 percent of one full step, non-cumulative: on a 1.8° motor the shaft can sit up to 0.05 × 1.8° = ±0.09° from the commanded position at any point of travel, and the error does not grow as the axis turns. Microstepping's documented benefit is smoother, quieter motion between those positions. Raising the division raises resolution and smoothness; accuracy stays at the full-step figure.
Where commanded microsteps stop being real positions #
Divide the revolution by the division: a microstep at division m spans 360°/(200 × m). Set that span equal to the 0.09° band and m = 360/(200 × 0.09) = 20. Past x20, every commanded microstep sits inside the band; at x50 the 0.036° increment is under half of it, so the drive counts faithfully while adjacent counts stop being distinct positions the rotor can hold. The mechanism is torque: the restoring torque available per microstep shrinks as the division rises, and at high divisions it falls toward the motor's detent torque and the load's friction, so the rotor settles off the commanded increment or snaps over it. Commanded resolution then exceeds repeatable accuracy, which is exactly the x50 case.
The gearbox route to finer output resolution #
A gearbox of ratio r multiplies whatever the drive resolves: output counts per revolution = 200 × m × r, and each output increment is 360° divided by that count. Torque at the load becomes motor torque × r × gearhead efficiency, and the load inertia the motor sees drops by r². The motor must spin r times faster for the same load speed, so the pulse rate rises by the same factor — the retrofit that adds a gearbox without raising the drive rate is its own failure mode, covered in why a geared stepper runs slow until the pulse rate is raised. Because stepper torque falls as pulse rate climbs, the speed-torque curve at the new rate sets the usable margin, not the standstill holding figure — see why a stepper motor stalls above a certain step rate. Between the gearhead output and the driven shaft, a flexible shaft coupling absorbs the mounting misalignment without adding backlash of its own.
Worked example: counts, torque, inertia and pulse rate #
Example inputs, assumed for the arithmetic and not a rated system: a 200 full-step motor with 1.2 N·m holding torque (a datasheet figure for the exact motor), the drive at x10, a 10:1 gearhead at 90% efficiency (a datasheet figure), load inertia 0.0024 kg·m², motor rotor inertia 0.00004 kg·m², load speed 1 rev/s.
- Counts: 200 × 10 × 10 = 20,000 steps per output revolution; one increment = 360/20,000 = 0.018°. The error band divides with the ratio, to ±0.009° at the output, so each commanded increment is twice the band and the counts are real.
- Torque: 1.2 N·m × 10 × 0.90 = 10.8 N·m at the gearhead output.
- Inertia: 0.0024 kg·m² / 10² = 0.000024 kg·m² reflected to the motor. Against the 0.00004 kg·m² rotor that is a 0.6:1 inertia ratio; without the gearhead the same load sits at 60:1, far past the roughly 10:1 figure used as a rule of thumb for open-loop steppers.
- Acceleration torque at an example ramp of 100 rad/s²: reflected inertia × angular acceleration = 0.000024 kg·m² × 100 rad/s² = 0.0024 N·m, added to the load torque divided by ratio and efficiency. How the same inertia and margin figures set starting time is worked through in a worked motor starting time calculation.
- Pulse rate: the motor turns 10 × 1 rev/s = 10 rev/s, so the drive must accept 2,000 steps per motor revolution × 10 rev/s = 20,000 pulses/s = 20 kHz, comfortably inside ordinary drive limits. The x50 comparison on the same gearhead: 200 × 50 × 10 = 100,000 counts per output revolution at 0.0036° and 100 kHz, with each increment still finer than the ±0.009° band — resolution without repeatable accuracy. Controller pulse engines add their own ceilings, as in the documented case of a closed-loop stepper axis that will not move above 200 kHz.
Matching the route to the requirement #
| Requirement at the output | Route | Counts arithmetic | The limit that decides |
|---|---|---|---|
| Smooth motion, up to about 2,000 counts/rev | Microstepping alone at x8 to x16 | 200 × 10 = 2,000 counts/rev at 0.18° per count | Count larger than the mechanical band; no extra hardware |
| About 10,000 counts/rev with a ±0.1° tolerance | x50 alone, or gearhead for dependable increments | 200 × 50 = 10,000 counts/rev at 0.036° | Every count inside the mechanical band |
| About 20,000 counts/rev, dependable increments | Drive at x8 to x10 plus a 10:1 gearhead | 200 × 10 × 10 = 20,000 counts/rev at 0.018° | Gearhead backlash sets the reversal floor |
| About 100,000 counts/rev | Higher division on the geared axis, for counts | 200 × 50 × 10 = 100,000 counts/rev at 0.0036° | 100 kHz pulse budget; counts finer than accuracy |
| Increments repeatable below the gearhead backlash | No open-loop stepper meets it | Not reachable by division | Closed-loop servo axis with its own reduction |
What the gearhead costs #
Backlash comes first: the gearhead datasheet quotes it in arcminutes, and it sets the floor on repeatability every time the load reverses direction — no division setting removes it. Efficiency comes second: torque multiplication arrives as ratio × efficiency, and the same datasheet carries the efficiency figure. Speed comes third: the motor runs r times faster for the same load speed, the pulse budget moves with it, and the gearhead's own input inertia (also a datasheet figure) adds on the motor side. One safety note: an unpowered or disabled stepper holds no torque, so if the load can fall, overrun or over-travel on power loss, add a spring-applied brake, counterbalance or fail-safe return sized by the machine's risk assessment under the applicable machinery safety standard.
The decision #
- Up to about 2,000 counts per revolution, or smoothness alone: microstepping at x8 to x16. No gearbox, and every increment stays larger than the mechanical band.
- Around the x50 ceiling with a tolerance near ±0.1°: x50 is acceptable arithmetic with undependable increments. Take the 10:1 gearhead at x10 instead.
- Counts in the tens of thousands and up — 100,000 counts per revolution is 200 × 50 × 10 with a 100 kHz pulse budget: take it when the specification asks for resolution, expect the output increments to be finer than the accuracy, and let the gearhead backlash stand as the reversal floor.
- Increments that must repeat below the gearhead backlash figure: no open-loop stepper meets that. Move to a closed-loop servo axis with its own reduction, which measures position instead of assuming it.
Questions asked
Does microstepping increase available holding torque?
No, it slightly reduces it. A two-phase motor holds its datasheet torque with two phases fully on at a full-step position; at a microstep position between full steps the two phases share the load, and the holdable torque falls to about 70 percent of the full-step rating. Size the holding requirement, and any vertical or pressurized load, on the full-step figure.
How do I measure what my axis can actually repeat?
Command the axis out and back over a fixed travel, for example 1,000 microsteps, ten times, and read the return position with an independent encoder or a dial indicator. The spread of those ten return readings is the real repeatability; the commanded step size is not. Run the test after reversing direction to expose backlash, and at duty speed to expose lost steps.
What microstep setting suits a 10:1 gearhead?
Set the lowest division that still runs your speed smoothly, usually x8 to x10 on a modern drive; the gearhead supplies the count multiplication. Check two figures on the drive before ordering: its maximum pulse input rate and the lowest division it offers. Past about x20 the division adds counts finer than the motor's error band anyway, so a higher setting on a geared axis buys nothing.
When is a stepper the wrong choice for fine resolution?
When the error budget is tighter than the gearhead's backlash. Gearing cannot remove the reversal floor, because it comes from the mechanics, not the counts. If the process needs increments repeatable below the backlash figure of the smallest practical gearhead, move to a closed-loop servo axis with its own reduction: it measures shaft position instead of assuming it, and reports the error instead of accumulating it.