Selection guide
Servo or stepper motor for smooth motion at 0.001 rpm
Short answer
Smoothness at 0.001 rpm is fixed by how many position increments the drive commands per revolution, not by motor type. A servo with a 1 Vpp sine encoder interpolated in the drive moves one count about every 14 ms; a 1/256 microstepped stepper moves one increment every 1.17 s. Choose the servo with high-resolution feedback, specify stall torque for the load, and verify with a 24-hour encoder log.
On this page
- What this creep speed demands of the drive
- Increments per revolution decide smoothness
- The feedback sets the step, not the motor
- Example: increment timing and power at 0.001 rpm for a 3 N·m axis
- When a microstepped stepper is enough
- Gearing multiplies resolution
- How to verify the result
- The decision
- Questions asked
Use a servo with a 1 Vpp sine encoder and a drive that interpolates it internally. At 0.001 rpm the axis takes 16 h 40 min per revolution, so smoothness is decided by how often the drive can command a fresh position increment, not by whether the motor is brushed, brushless or a stepper. A servo with roughly four million interpolated counts per revolution moves one count every 14 ms, which reads as continuous motion; a 1/256 microstepped stepper moves one increment every 1.17 s, smooth over hours and visibly stepped over seconds. The stepper is the fallback for applications where hours-scale smoothness is enough.
What this creep speed demands of the drive #
At this speed the motor delivers torque but essentially no mechanical power, so the power rating is not the selection problem. The problem is position quantisation: a digital drive commands motion in fixed increments, and the axis is either at rest on one increment or moving to the next. Whether that reads as smooth depends on the observation window, so define the window first. If someone will watch the output over seconds, you need increments arriving many times per second; if the motion only has to average out over hours, less than one increment per second is enough.
The second effect is torque ripple. Sine commutation is the smoothest drive scheme at very low speed, and a position loop with fine feedback damps the motor's cogging; an open-loop stepper has no loop, so its ripple passes straight through to the load.
Increments per revolution decide smoothness #
One revolution at the target speed takes 1000 min, which is 60,000 s. Divide that by the increments the drive commands per revolution and you have the interval between moves:
increment interval = 60,000 s / (increments per revolution)
| Configuration | Increments per revolution | Interval between moves | Seconds-window verdict |
|---|---|---|---|
| Stepper, full step | 200 | 300 s | visibly stepped |
| Stepper, 1/50 microstepping | 10,000 | 6 s | visibly stepped |
| Stepper, 1/256 microstepping | 51,200 | 1.17 s | stepped within seconds, smooth over hours |
| Servo, 10,000-line square-wave encoder (x4 quadrature) | 40,000 | 1.5 s | no better than the microstepped stepper |
| Servo, 1 Vpp sine encoder, 1024 cycles interpolated x4096 | 4,194,304 | 14.3 ms | reads as continuous |
| Servo, 24-bit absolute encoder | 16,777,216 | 3.6 ms | reads as continuous |
The motor type barely appears in that table. A servo with an ordinary square-wave encoder is no smoother than a microstepped stepper; what separates the smooth rows is interpolated or very-high-count feedback.
The feedback sets the step, not the motor #
A 1 Vpp sine encoder sends differential analog sine and cosine signals in quadrature at 1 Vpp amplitude, typically 512 or 1024 cycles per mechanical revolution, and the drive interpolates inside each cycle - a factor of 4096 is common. That interpolation is where the millions of counts come from.
Given the same feedback, brushed and brushless motors are equally smooth, so the motor choice becomes a supply question: a brushless AC servo with an integrated sine encoder is the standard packaged combination, while a brushed DC servo suits a 24-48 VDC bus. Bolting an encoder onto a stepper makes it closed loop, which catches lost steps but leaves the microstep increment unchanged - it fixes accuracy, not smoothness. For the resolution-versus-step-angle trade at ordinary speeds, see servo positioning resolution versus stepper step angle.
Example: increment timing and power at 0.001 rpm for a 3 N·m axis #
Inputs, as a calculated example rather than a measured result: the target creep speed, a 120 W class motor carrying a 3 N·m load, a 1/256 microstepping stepper, and a sine-encoder servo.
Revolution time: t = 1 / 0.001 rpm = 1000 min.
Stepper: 200 steps x 256 microsteps = 51,200 increments per revolution, so the interval between moves is the 60,000 s revolution time / 51,200 = 1.17 s, about 0.85 moves per second.
Servo: 1024 sine cycles x 4096 interpolation = 4,194,304 counts per revolution, so the interval is the same 60,000 s / 4,194,304 = 14.3 ms, about 70 counts per second.
Power at speed: the angular velocity is 2pi x 0.001 rpm / 60 = 0.000105 rad/s, so P = 3 N·m x 0.000105 rad/s = 0.00031 W, about 0.3 mW. The 120 W rating implies a rated speed of 120 W / 3 N·m = 40 rad/s, or about 382 rpm: you pay for that speed range - homing, setup moves, acceleration - not for the creep.
Consequence: at the target speed the servo works at thermal standstill, so its continuous stall torque must cover the load torque with margin, and the effort belongs in the feedback and the interpolating drive.
When a microstepped stepper is enough #
Take the stepper when the observation window is hours: the axis averages the commanded speed exactly, moving one microstep at a time with a dwell between moves, and nothing in the drive fights the load between moves. Two conditions keep it honest. The load torque must sit well inside the motor's torque curve with margin, because at creep speed a lost step is silent - no sound, no visible jerk - and the error accumulates for hours. And if the load can ever stall the motor, add an encoder and close the loop, picking it as described in choosing encoder resolution to match a stepper step response.
Gearing multiplies resolution #
A reducer multiplies the increments per output revolution by its ratio. A 100:1 stage on the microstepped stepper gives the output 51,200 x 100 = 5,120,000 increments per revolution, so the interval between output moves becomes the revolution time / 5,120,000 = 11.7 ms - the same territory as the interpolated servo. The price is backlash and torsional wind-up: on a one-direction creep, backlash never enters the motion, but a bidirectional axis needs a low-backlash stage.
Do not gear a standard servo to fix smoothness. The required ratio is motor speed divided by output speed, so a 3000 rpm servo would call for 3,000,000:1 and even a 60 rpm motor needs 60,000:1 - a multistage train that adds the very backlash and wind-up you were trying to avoid. Gear to multiply torque or to rescue a stepper; fix smoothness with feedback.
How to verify the result #
Command the creep and log encoder counts for 24 h. A day is 1440 min, so at 1000 min per revolution the axis must show 1.44 revolutions; a shortfall means lost steps or a slipping transmission, not sensor noise. Judge smoothness on a 1 s window: the interpolated servo should deliver its roughly 70 counts per second as a ramp with no staircase, while the stepper shows one move per increment with a dwell between moves. Measure cogging at zero speed with a torque transducer - as a rule of thumb, keep it below about 2% of rated torque in this class - and run a 4 h thermal soak at load torque, keeping the winding temperature rise inside the insulation class limit, which is 80 K for Class B at a 40 °C ambient under IEC 60085.
One safety note: the overnight log runs unattended, and at this speed the axis looks de-energized while it turns, so guard it and lock it out as the machine's risk assessment requires - the general practice of ISO 12100.
The decision #
- Smooth within a seconds window, bidirectional or positioned: brushless AC servo with an integrated 1 Vpp sine encoder in the 1024-cycle class and a drive that interpolates internally, with continuous stall torque at or above the load torque. This is the default answer.
- DC bus only, 24-48 V: brushed DC or brushless DC servo with the same sine feedback and an interpolating drive; the smoothness lives in the feedback, so match it and the supply is a free choice.
- Hours-scale smoothness, one direction, simple wiring: the 1/256 microstepped stepper, adding a 100:1 stage if the seconds window starts to matter.
- Piezo and ultrasonic motors come up in these applications but sit in a low-torque specialty class; keep them for vacuum or magnetic-cleanliness jobs where the torque requirement shrinks below this class.
For the torque-and-duty half of the choice at ordinary speeds, see stepper versus servo motor selection by torque and duty.
Questions asked
Does a closed-loop stepper run as smoothly as a servo at these speeds?
No. Closing the loop with an encoder detects and corrects lost steps, so accuracy improves, but the commanded increment is still one microstep and the seconds-scale stepping remains. Only finer feedback or a gear ratio shrinks the increment; the loop cannot interpolate what the drive never commands.
How fast must the drive's position loop update for smooth creep?
With one count arriving every 14 ms, a loop updating at 1 kHz already splits each count interval into roughly 14 corrections, and most servo drives update faster than that. Spend the specification effort on the encoder's interpolation factor instead: below the count rate, the loop has nothing finer to act on.
Why does a sine encoder give finer feedback than a square-wave encoder?
A square-wave encoder reports position only when an edge passes, so its resolution is fixed by the line count. A sine encoder delivers continuous analog sine and cosine voltages, and the drive computes the angle inside each cycle from the ratio of the two amplitudes, which is what interpolation does. That is how a modest cycle count becomes millions of counts.
Will a microstepped stepper overheat while creeping?
It can. A stepper at near-zero speed carries close to its set current continuously, so the creep case is thermally the stall case. Set the drive's standstill current to the holding torque the load actually needs, and check the motor against its stall heating point rather than its moving torque curve.
Can a hobby-style PWM servo do this job?
Only for a partial turn. A hobby servo updates its commanded position roughly every 20 ms and travels about 180 degrees, so it can creep but cannot rotate continuously, and its internal potentiometer feedback is coarse. For continuous rotation at this smoothness, use the industrial drives described above.