Short answer

A 0.018° move needs 360 ÷ 0.018 = 20,000 usable feedback counts per revolution, which come from the encoder and the drive's decoding and scaling, not from the servo label. Matching 3,000 command pulses per revolution on a stepper and a servo only matches command scaling; short-time overload capacity and high-speed performance still differ.

On this page
  1. Where the positioning increment comes from
  2. Reading an encoder's usable count
  3. What a stepper's step angle gives you
  4. Sizing feedback and command scaling for a 0.018° direct-drive move
  5. Why 3,000 pulses per revolution equalizes only the scaling
  6. Comparing systems, not components
  7. Verifying the increment on a real axis
  8. Questions asked

A servo makes 0.018° moves because its feedback resolves them, not because the nameplate says servo: 360° ÷ 0.018° = 20,000 usable counts per motor revolution on a direct-drive axis. A synchronous motor fitted with an encoder of the same usable count, driven by a drive that closes the position loop on it, makes the same move. When a stepper and a servo are both set to 3,000 command pulses per revolution, only the command scaling matches — 0.12° per pulse on either motor — while short-time overload capacity and high-speed performance stay different. Here is what sets each number and how to check it on a real axis.

Where the positioning increment comes from #

The increment belongs to the feedback device and to what the drive does with it, not to the motor's label. A servo loop compares the encoder's measured position with the commanded position and drives torque until the difference is closed, so the smallest move it can distinguish and correct is one feedback count. On a direct-drive shaft, the angle per count is 360° divided by the usable counts per revolution; any gear or belt ratio between motor and load divides that motor-side increment by the ratio to give the increment at the load. The feedback side of that choice is a decision of its own — choosing encoder resolution to match a stepper step response covers it in depth.

Without an encoder and a drive closing the loop on it, a synchronous motor positions only as finely as its command source and pole structure allow, which is why the same motor can be coarse on one system and fine on another.

Reading an encoder's usable count #

Incremental rotary encoders state resolution in pulses per revolution (PPR), also called line count; a 2000 PPR unit resolves half the angle of a 1000 PPR one. Servo drives commonly count all four edges of the two quadrature signals, which makes usable counts per revolution = PPR × 4, so the drive's configured decoding — not the number printed on the encoder — is what sets the increment whenever the two differ.

Serial and absolute encoders built into servo motors are specified in bits instead: a 16-bit encoder reports 65,536 counts per revolution, and each additional bit doubles the count. Resolution and accuracy are separate quantities — resolution is the smallest increment the system can measure, accuracy is how far the reported position may sit from the true angle — so an axis can resolve a fraction of its required increment and still miss it through the encoder's accuracy band, coupling wind-up or backlash. Size the resolution first, then check accuracy and mechanics against the permitted error.

What a stepper's step angle gives you #

The common two-phase hybrid stepper indexes in a 1.8° full-step angle, 200 full steps per revolution, and microstepping divides that angle electronically. The step angle is what the motor is built to hold; the realized position of a microstep depends on load torque and drive current, and when load torque exceeds what the motor can deliver, the rotor skips whole steps with nothing to report the loss. A servo reports and corrects its error instead, and the drive faults when following error crosses its configured limit rather than drifting silently. That behavioral difference survives any matching of pulse counts.

Sizing feedback and command scaling for a 0.018° direct-drive move #

Inputs, each with its source:

  • Required increment: 0.018° per commanded move at the motor shaft, direct drive, no reducer — the requirement as stated for the axis.
  • Command scaling as found: 3,000 command pulses per motor revolution, read from the drive's configuration.
  • Candidate feedback A: a 2,000 PPR incremental encoder — the line count its datasheet states — with the drive decoding all four quadrature edges.
  • Candidate feedback B: a 16-bit encoder, specified at 65,536 counts per revolution.

The rule in words: the axis needs at least 360° ÷ required increment usable feedback counts per revolution; an incremental encoder under quadrature decoding provides PPR × 4 usable counts; and one command pulse commands 360° ÷ command pulses per revolution of rotation.

The arithmetic, written out:

  • 360° ÷ 0.018° = 20,000 usable counts per revolution required.
  • Candidate A: 2,000 PPR × 4 = 8,000 counts per revolution, so one count is 360° ÷ 8,000 = 0.045° — 20,000 ÷ 8,000 = 2.5 times too coarse for the move.
  • Candidate B: one count is 360° ÷ 65,536 = 0.0055°, and 65,536 ÷ 20,000 ≈ 3.3 feedback counts fall inside each required increment.
  • Command side as found: one pulse is 360° ÷ 3,000 = 0.12°, which is 0.12° ÷ 0.018° ≈ 6.7 times coarser than the move.

Decision: below 20,000 usable feedback counts per revolution the axis cannot represent the move at all, so candidate A fails on resolution and no tuning recovers it. Candidate B passes with margin, but the command scaling must rise to at least 20,000 pulses per revolution — set through the drive's electronic gear ratio or the controller's pulses-per-revolution setting — so one command pulse is one 0.018° increment spanning about 3.3 feedback counts. This is a calculated example for these inputs, not a measured result; the measured check follows below.

Why 3,000 pulses per revolution equalizes only the scaling #

Set both drives to 3,000 command pulses per revolution and one command pulse commands 0.12° of motor rotation on either system: every move scales the same and every position command lands in the same units. That is all it equalizes.

What survives the matched pulse count is the short-time overload capacity and the high-speed performance. A servo works through a momentary overload by driving more current and correcting the resulting error; a stepper that runs out of torque loses steps, and its error accumulates silently. The choice between them is stepper versus servo motor selection by torque and duty across the whole operating range, not a pulse count. A closed-loop stepper narrows the gap by adding its own feedback and position loop, but its tuning and limits are its own, and the command-scaling point above is unchanged.

Comparing systems, not components #

An encoder is a measuring device; a servo motor is one part of a motion system. A microprocessor-controlled mechanism with encoder feedback and a servo-controlled mechanism differ in which device measures position, which loop acts on that measurement, and what the load demands — not in anything attached to the word servo. A synchronous motor, an encoder with sufficient usable counts and a drive closing the position loop on that encoder together form a servo positioning system in function. The drive and command electronics are part of the comparison too — why a stepper controller cannot drive a servo motor is a question of drive architecture, separate from resolution.

Verifying the increment on a real axis #

Matching the numbers proves the scaling, not the arrival. Use the drive's diagnostics to watch commanded position, actual position and following error, and command a single small move, then a full revolution, first at no load and then at working load and speed. A following error that grows with load points to torque, tuning or mechanics — never fix it by re-scaling command pulses. Confirm at the load with an independent measurement finer than the permitted error, one tenth of the tolerance being a workable rule of thumb, because the drive can only report what its encoder sees, which is upstream of any backlash or compliance in the train. Run these moves with workpiece and tooling clear of the axis and hands out of the drivetrain, and apply the machine's lockout procedure before reaching inside a guard to set up the measurement.

If the commanded 0.018° increments measure inside tolerance across load and speed, resolution, scaling and mechanics are proven together. If they do not, the numbers above say which of the three to attack first: feedback count, command scaling, or the mechanics between motor and load.

Questions asked

How many counts per revolution do 17-bit and 20-bit encoders give?

Bits convert by powers of two: 17 bits give 2^17 = 131,072 counts per revolution and 20 bits give 2^20 = 1,048,576, with each added bit doubling the count. The 16-bit encoder's 65,536 counts already put about 3.3 counts on a 0.018° increment, so more bits buy margin and finer interpolation rather than changing that pass/fail result.

How can I measure a 0.018° move at the load without lab instruments?

Convert the angle to a linear distance at a known radius. 0.018° is 0.018 × π ÷ 180 = 0.000314 radians, which at a 100 mm radius is an arc of 100 mm × 0.000314 = 0.031 mm. A dial indicator graduated to 0.01 mm, touching a fixture at that radius, resolves the move; repeat the command several times and read the spread rather than trusting one reading.

Can I get finer moves just by raising the command pulses per revolution?

Only down to the feedback resolution. Raising the command scaling through the electronic gear ratio makes commanded increments finer, but below one feedback count per increment the drive cannot tell them apart, and torque and inertia decide whether the load follows. Set command scaling so an increment spans at least one feedback count — 20,000 pulses per revolution against 65,536 counts gives about 3.3 — and confirm the controller can output that rate at top speed.

Why do my encoder's PPR and the drive's counts per revolution disagree?

PPR is the line count of the encoder disc, while counts per revolution on many datasheets already includes the quadrature multiplication. If a drive is configured for one and fed the other, every scaling and gear-ratio setting lands wrong by a factor of four. Check the drive's feedback configuration for the count it is actually using, then command exactly one revolution and confirm the drive reports a full 360°.

Keep reading

  • Troubleshooting

    Fix Servo Travel Error After Swapping Resolver and Encoder

    Travel that does not match the position display after a resolver-to-encoder swap is a scaling fault: the drive or the technology axis is still converting counts with the other feedback's increments per revolution. Measure one commanded move and divide actual by displayed travel; a constant ratio equal to the resolution ratio names the encoder data. Fix both layers, re-home, then re-tune.

    Servo and stepper motion

  • How-to

    Setting Up Servo Electronic Gearing With Registration Correction

    Gear the folder servo to the web encoder with one fixed electronic gear ratio and apply registration error as a bounded phase trim ramped across the 100 to 200 ms between corrections. At 150 m/min a 0.1 mm tolerance is 40 microseconds of web travel — about eight 0.0127 mm increments — so doubling or halving a pulse train for six pulses trips following error, while a ramped trim changes speed by 0.04 percent.

    Servo and stepper motion

  • Troubleshooting

    Why an EtherCAT CSP Stepper Axis Enables but Does Not Move

    Holding torque on Servo On proves only that the power stage energizes the windings. In cyclic synchronous position mode the axis moves only when the drive accepts each new 0x607A target and no internal limit refuses it, so check Statusword bit 11 first, then the drive's speed, current and software position limits, then the position unit scaling between controller and drive.

    Servo and stepper motion

Why a stepper motor handles 1 revolution per day rotation