Troubleshooting
Why an EtherCAT CSP Stepper Axis Enables but Does Not Move
Short answer
Holding torque on Servo On proves only that the power stage energizes the windings. In cyclic synchronous position mode the axis moves only when the drive accepts each new 0x607A target and no internal limit refuses it, so check Statusword bit 11 first, then the drive's speed, current and software position limits, then the position unit scaling between controller and drive.
On this page
- Why does the shaft lock on Servo On but refuse every move?
- What do you check first when a CSP axis will not move?
- What does Statusword bit 11 mean with the limit switches off?
- Why does the watch window show a changing target while the shaft stands still?
- How do you test position scaling with one commanded move?
- Which drive settings stop a move without tripping a fault?
- How do you know the axis is actually fixed?
- Questions asked
An EtherCAT stepper axis that locks when you enable it and then ignores every commanded move has a healthy power stage and a motion generator refusing the command. Holding torque is not motion. In cyclic synchronous position mode, mode 8 in 0x6060, the drive turns only when it accepts a new 0x607A target every cycle and nothing inside it vetoes the move: a software position limit, a speed limit or a current limit can all do that with the limit switches off. Read Statusword bit 11 first, then the received target and its units; the fix is nearly always a configuration value, not a component.
Why does the shaft lock on Servo On but refuse every move? #
Because Servo On only proves the power stage: the windings are energized and the shaft holds, but in cyclic synchronous position mode motion needs a new 0x607A target accepted every cycle with no drive-side restriction refusing it.
CSP divides the work. Your controller computes the trajectory and streams position targets; the drive's job is to sit on each target on time. The CiA402 state machine that carried you to Operation Enabled, Controlword 128 to clear the fault then 6, 7 and 15, is a chain separate from the motion generator, which is exactly why a fully enabled axis can stand still.
The bench test in the drive vendor's own tool already cleared the motor, the wiring and the current setting, and the unloaded shaft removes torque from the question. If you want the motor cleared on the record too, the bench checks are the ones in how to tell if a servo motor is actually faulty. One dead end to close: when no physical brake is wired, the holding-brake flag in the vendor's CiA402 diagnostic tool is an internal indication, not hardware acting on the shaft.
What do you check first when a CSP axis will not move? #
Statusword bit 11 first: read 0x6041 live during a commanded move, because software position, speed and current limits inside the drive set that bit and block motion while both external limit inputs read off.
Work in this order, and make every step a read rather than a change:
- Decode 0x6041 while the move is being commanded, not at rest, and record whether bit 11 is set.
- Confirm 0x6061 still reports 8 during the move; a mode written at startup does not guarantee the mode during execution.
- Read the drive's received 0x607A value back from the slave, not only from the controller's watch window, because a number changing in the master's process image does not prove the slave holds the same number.
- Read the drive's software position limits, its maximum speed limit and its current limit, with their units, from the drive's own parameter list.
- Confirm the slave was built from the manufacturer's device description file for the exact drive, not a generic CiA402 template.
- Read the position the drive reports as actual and compare it against a mark on the shaft.
What does Statusword bit 11 mean with the limit switches off? #
Bit 11 of 0x6041:00 is the internal-limit-active bit in the CiA402 profile: the drive is refusing motion for a reason inside itself, most often a software position limit, a speed limit or a current limit, not a wired switch.
The two observations that look contradictory, external positive and negative limits reading off at rest while bit 11 appears in a live read, are compatible. What the bit does next tells you which restriction:
| What you observe | Most likely branch | Confirming check |
|---|---|---|
| Bit 11 set before any command | A persistent restriction, such as software limits bracketing the present position | Read the configured position limits and compare them to the reported actual position |
| Bit 11 appears as the target changes | The commanded target crosses a configured boundary | Correlate the bit with target magnitude and direction, both ways |
| One direction moves, the other refuses | A directional limit or position boundary | Compare the positive and negative limit input states and the software limits |
| Neither direction moves, bit 11 clear | Target transfer, scaling or mode, not a limit | Move to the scaling test below |
The fix for a genuine limit conflict is to correct the configured limit so it reflects the axis's real travel, never to defeat a limit that is doing its job.
Why does the watch window show a changing target while the shaft stands still? #
A changing 0x607A in the controller's watch window proves the controller computes a trajectory; it does not prove the drive received those numbers or reads them in the same units, and that gap is where this fault lives.
PDO mapping says which objects travel on the network; it says nothing about what their values mean. The rising following error tells you only that commanded trajectory and feedback are separating, and it does not localize the break. That symptom class, command and feedback disagreeing on units, is the same one behind the servo travel error after a resolver and encoder swap, and it is settled the same way: one deliberate commanded move, observed at the shaft.
Also settle what the drive reports as its actual position. An internally generated position count and an encoder-measured shaft position answer different questions, and a shaft mark settles which one you are reading.
How do you test position scaling with one commanded move? #
Command one revolution and watch the shaft: on a 1.8° motor with 16 microsteps, 3200 counts must turn the shaft exactly once, and any other angle tells you the ratio between controller counts and drive increments.
Run the test with the shaft uncoupled and the disable path in reach, because an axis whose units disagree can travel many times the distance you commanded.
A calculated example for these inputs, not a measured result:
- Motor: 1.8° per full step, so 360 / 1.8 = 200 full steps per revolution.
- Drive microstep setting: 16, so 200 × 16 = 3200 increments per revolution, and one increment is 360 / 3200 = 0.1125°.
- Controller scaling: 65536 counts per revolution.
- Command: one revolution in 2 s, so the controller streams a total change of 65536 counts into 0x607A.
If the drive reads those counts as its own increments, it is asked for 65536 / 3200 = 20.48 revolutions in 2 s, which is 10.24 rev/s × 60 = 614 rpm. Against a speed limit set to, say, 300 rpm, the demand is over the cap by 614 / 300 ≈ 2 times, and the drive clamps or refuses while the following error climbs.
Now the discriminating read: command 3200 counts. Matched scaling returns exactly one shaft revolution. A drive still assuming 65536 counts per revolution moves 3200 / 65536 = 0.049 revolution, about 17.6°, a shaft that creeps while the error grows. The decision: set the position scaling factor, the electronic gear or unit exponent as the drive's documentation names it, so both sides use the same counts per revolution, then repeat the 3200-count test in both directions. A deeper walkthrough of CSP position scaling between a controller and a drive covers the same mismatch on another controller-drive pair.
Which drive settings stop a move without tripping a fault? #
Three of them: a software position limit pair, a maximum speed limit, and a current or torque limit, and each refuses or clamps the commanded motion silently, with the axis enabled, the mode correct and no fault raised.
Know where they live before you touch them. On this class of EtherCAT stepper drive the DIP switches only set the node address, SW1 through SW7, and a self-test on SW8; the current setting and the microstep resolution are network configuration in CoE objects 0x2000 and 0x2001. Read the configured values and their units there before changing anything, because a value that looks like a current may be a code or a percentage depending on the drive.
Keep thermal behavior and command behavior separate. A shaft standing still while commands change says nothing about temperature or torque margin; a current restriction announces itself in current feedback, temperature indications and the fault history. Treat the fault you cleared during bring-up as a separate event from the refusal to move, until a repeated test ties them together.
How do you know the axis is actually fixed? #
When one commanded revolution returns exactly one shaft revolution in both directions, bit 11 stays clear through the move, 0x6061 holds 8, and the following error falls back to its idle value the moment the jog stops, the command path is whole.
Couple the load and repeat the same test at working speed. If the axis now stalls partway under load, you have a current and duty decision, a different problem with different numbers than the silent refusal you just closed out.
Questions asked
Does holding torque after Servo On prove the drive and motor are good?
It proves the enable chain and the power stage: the drive reached Operation Enabled and is energizing the windings. It exercises neither the cyclic target path nor the feedback path, so it cannot clear a limit, scaling or mode problem. With the axis unloaded and the drive proven on the bench, treat the motor as cleared and stay on the command path.
Can a Distributed Clock problem stop a CSP axis from moving?
Rarely this cleanly. A synchronization fault normally announces itself in the EtherCAT diagnostics first, as missed cycles or sync and counter errors, before motion refuses. If the cycle time, sync mode and sync unit are configured and matching and the diagnostic counters stay quiet, changing the cycle time treats a problem you do not have; keep reading limits and units instead.
Why does the following error climb if the motor is standing still?
The controller compares its commanded trajectory against feedback and accumulates the difference, so the error grows whenever the two separate, at roughly the rate of the commanded move. Use that rate: if it grows exactly as fast as the commanded velocity, the move never executed or feedback is frozen; if the shaft creeps while the error grows, suspect unit scaling between command and feedback.
Should you raise the motor current when the axis will not move?
Not on this symptom. Current is the answer when an axis moves but stalls under load or loses position at speed. A shaft that stands perfectly still with no load attached and a clean enable has a command problem, and extra current only adds winding and drive heating. Revisit current after the scaling test passes and real load is coupled.
Does the device description file matter if the PDO mapping already looks right?
Yes. A generic or wrong-version file can map the right objects while carrying the wrong defaults for units, limits and operating mode, and those defaults follow the axis into operation. Load the manufacturer's current device description for the exact drive before debugging values, so the objects you read mean what the vendor says they mean.