Short answer

The motor that wins a robot joint is the one with torque available at the joint's required speed, held through the real duty cycle. A stepper's holding torque and a geared servo's stall torque describe standstill; compare the stepper's torque-speed curve at the motor speed your move demands against the servo's continuous rating. The worked elbow example shows the arithmetic and the thresholds.

On this page
  1. What each torque number actually measures
  2. Torque at the speed the move needs
  3. Zero motion is not zero heat
  4. Stepper, packaged servo, industrial servo side by side
  5. Worked example: an elbow joint, 300 mm forearm, 0.5 kg payload, 90 in 0.5 s
  6. The decision
  7. Questions asked

Neither the stepper's holding torque nor the servo's stall torque decides a robot joint. The motor that wins is the one delivering torque at the shaft speed the move demands, sustained through the duty cycle the joint actually sees. A stepper's 84 oz-in is measured at zero speed; a packaged servo's stall figure is a momentary, supply-voltage-dependent number; an industrial servo's continuous rating is a thermal limit. Put the three on the same operating point and the choice becomes arithmetic. Here is what each rating means, where the two motor types genuinely differ, a fully worked elbow joint, and the thresholds that settle it.

What each torque number actually measures #

Holding torque is what a stepper produces at standstill with rated current in its windings: the top of its curve, at 0 rpm. The 84 oz-in figure that anchors this comparison is one motor's rating, not a ceiling for the frame. NEMA 17 fixes a 1.7 in mounting face and nothing else; longer stacks in the same face carry more torque. Convert before comparing: 84 oz-in × 0.00706 N·m per oz-in = 0.59 N·m, or 84 × 0.0720 = 6.0 kg·cm.

A stepper's available torque falls as speed rises, because winding inductance and back EMF limit how fast current can build in each step. A higher supply voltage drives current in faster and holds the curve up longer at speed. The published torque-speed characteristic for the exact motor, driver and supply voltage is the trustworthy source, and it is a curve, not a number.

Stall torque, on a packaged RC or bus servo, is output-shaft torque at standstill, held momentarily. One documented example lists 3.3 kg·cm (0.32 N·m) stall at 4.8 V and 4.1 kg·cm (0.40 N·m) at its higher supply, so the headline moves with voltage before the load even enters. Stall is not continuous torque; it is the number the motor reaches just before it stops being a motor.

Industrial servo datasheets separate continuous torque, what the motor sustains at thermal equilibrium, from peak torque for acceleration, with peak typically 5 to 10 times continuous. The joint's holding duty lives under the continuous number; its acceleration lives under the peak number and that peak's time limit.

Torque at the speed the move needs #

A servo delivers its continuous torque from zero up to rated speed and trades torque for speed at constant power beyond that. A stepper starts at its best at zero speed and gives torque back as speed climbs, on a slope set by the winding and the drive voltage. Same joint, opposite-shaped supply of torque.

Reduction multiplies what the joint sees, but it also multiplies what the motor must turn: motor speed = joint speed × ratio. Adding ratio to a torque-starved stepper chases its own tail, because each doubling of joint torque doubles the motor rpm and pushes the operating point further down the falling curve. Size stepper joints motor-side first, reduction second.

On the control side the two are different animals: a stepper controller cannot drive a servo motor, and the driver you already own may settle the question before torque does. Counting step pulses proves a command was sent, not that the shaft arrived; feedback changes that, and whether an encoder makes a stepper closed loop is its own question. A bus servo may regulate position internally while reporting nothing back, so check what the interface exposes before counting on it.

If the candidate motor is already on your bench, one measured point is cheap: fix a lever arm of known length, load it with known weights, and raise the speed until it stalls. That is your torque at that speed, and a measured point beats any rule of thumb.

Zero motion is not zero heat #

Holding an arm against gravity is continuous work at 0 rpm. A stepper driver keeps rated current in the windings at standstill, so the hold costs full winding heating for as long as it lasts; that is the motor's design, and its rated temperature is the ceiling. A servo holding against gravity draws torque-producing current in proportion to the hold. Either way, the selection quantity is the RMS torque of the real duty cycle against the continuous rating, plus the peak torque against the peak rating and its time limit.

One safety note, because it belongs here: a joint that holds its load on motor torque drops that load the moment power or the drive is lost, so a gravity-loaded arm needs a holding brake, a counterbalance, or a maintenance procedure that blocks the arm before anyone reaches underneath.

Stepper, packaged servo, industrial servo side by side #

Deciding quantity Open-loop stepper, NEMA frame Packaged RC or bus servo Industrial servo with drive
Headline rating Holding torque at 0 rpm, e.g. 84 oz-in (0.59 N·m) Stall torque at the output, moves with supply voltage Continuous torque, thermally rated, with peak typically 5-10x
Moving torque Falls with speed; read the curve for the exact motor, driver and voltage Continuous torque sits well below stall; gearing already inside Continuous torque flat to rated speed
Holding a load Full holding torque, full winding current at standstill Torque-proportional current while holding Torque-proportional current while holding
Position verification Silent step loss unless the loop is closed Depends on model and interface; some report position and faults Drive reports position, following error and faults
Rotation Continuous, multi-turn Limited angle or continuous, per model Continuous, multi-turn
Electronics External current-regulating driver Integrated controller, power plus command signal Matched separate drive closing the loop on its own feedback

If your axis is about holding speed rather than making torque, the weighting shifts; that case is covered in choosing a servo or stepper for a 1% speed-regulation axis.

Worked example: an elbow joint, 300 mm forearm, 0.5 kg payload, 90 in 0.5 s #

Inputs #

  • Forearm: 1.5 kg, center of mass 150 mm from the elbow (example input, a typical small-arm forearm).
  • Payload: 0.5 kg at 300 mm from the joint (example input).
  • Move: 90 degrees in 0.5 s on a triangular speed profile, accelerating half the move and decelerating half (example input).
  • Stepper candidate: the 84 oz-in motor this comparison started from, 0.59 N·m holding.
  • Reductions tried: 10:1 and 20:1, one belt stage at an assumed 90% efficiency (assumption).
  • Constants: g = 9.81 m/s²; 1 oz-in = 0.00706 N·m.
  • Sizing rule of thumb: count on half the holding torque at working speed, then verify on the published curve.

The rule in words #

Gravity torque is each mass times g times its distance from the joint, summed. Inertia about the joint is the forearm as a rod pivoted at its end, (1/3)mL², plus the payload as a point mass, mr². For a triangular profile, peak angular acceleration is 4Δθ/t² and peak speed is 2Δθ/t. Peak joint torque is gravity plus inertia times acceleration, and motor-side demand is the joint value divided by ratio times efficiency.

The arithmetic #

Gravity torque: 1.5 kg × 9.81 m/s² × 0.150 m = 2.21 N·m; 0.5 kg × 9.81 m/s² × 0.300 m = 1.47 N·m; total 3.68 N·m.

Inertia: (1/3) × 1.5 kg × (0.300 m)² = 0.045 kg·m²; 0.5 kg × (0.300 m)² = 0.045 kg·m²; total 0.090 kg·m².

Acceleration: 4 × 1.571 rad ÷ (0.5 s)² = 25.1 rad/s². Acceleration torque: 0.090 kg·m² × 25.1 rad/s² = 2.26 N·m.

Peak joint torque: 3.68 + 2.26 = 5.94 N·m. Peak joint speed: 2 × 1.571 ÷ 0.5 = 6.28 rad/s = 60 rpm.

Stepper at 10:1: the motor turns 600 rpm and must supply 5.94 ÷ (10 × 0.90) = 0.66 N·m. The half rule gives 0.59 ÷ 2 = 0.30 N·m available at working speed. Short by more than half.

Stepper at 20:1: the motor turns 1200 rpm and must supply 5.94 ÷ (20 × 0.90) = 0.33 N·m, still over half the holding torque at a speed where the curve is a small fraction of it. Fails. The standstill hold at 20:1 is 3.68 ÷ 18 = 0.20 N·m, comfortably inside 0.59 N·m, so the joint passes as a statue and fails the moment it moves.

Servo at 10:1: continuous requirement 3.68 ÷ 9.0 = 0.41 N·m, peak requirement 5.94 ÷ 9.0 = 0.66 N·m at 600 rpm motor speed. With peak allowances of 5 to 10 times continuous, a servo rated at exactly 0.41 N·m continuous still offers 2.05 to 4.1 N·m of peak, three to six times the demand, and 600 rpm sits deep inside any servo's constant-torque band.

Result and decision #

These are calculated values for the stated inputs, not measured results. Decision: the 84 oz-in stepper is out for this joint at every workable ratio; it needs the next stack length or frame up. A servo at 10:1 meets the joint with the datasheet thresholds of at least 0.41 N·m continuous and at least 0.66 N·m peak at 600 rpm. The general threshold: when motor-side peak demand at the required motor speed exceeds half the stepper's holding torque, drop the stepper. For this motor that limit is 0.30 N·m motor-side, which at 10:1 and 90% efficiency is 0.30 × 10 × 0.90 = 2.7 N·m of joint peak torque; joints below that number remain this motor's territory.

The decision #

Size first, select second: get the joint's gravity torque, peak torque and peak speed before opening any datasheet. Then commit on four checks.

Pick the open-loop stepper when the published torque-speed curve at your required motor speed clears peak demand with 30 to 50% margin (rule of thumb), the duty stays inside the motor's temperature rating, and silent position loss is acceptable or the loop is closed. Slow, predictable, mostly horizontal axes such as leadscrew slides, scanners and indexers are its home ground.

Pick the packaged servo when its continuous torque covers the RMS demand at the output, its peak covers the acceleration, its travel limits suit the joint, and its interface gives the position and fault reporting the machine needs. Pick the industrial servo when joint speed, sustained torque or diagnostics outrun the compact options. If the stepper passes, the ratio is the next decision, and belt or gearbox reduction for a stepper arm joint carries its own tradeoffs.

On the precision claims that start these comparisons: a step count is a resolution figure, not loaded accuracy, and a servo's repeatability comes from its feedback. Both collapse when the axis is torque-starved, because the stepper loses steps and the servo sits in following error. Torque at speed is the gate; precision is what you buy after the gate is passed.

Questions asked

How much of a stepper's holding torque can I count on while it is turning?

At standstill with rated current you get the full holding figure, but while turning you get the value the torque-speed curve shows at that speed, which is always lower. A workable rule of thumb is to design with no more than half the holding torque at working speed, and to treat even that as optimistic as speed climbs. The published torque-speed curve for your exact motor, driver and supply voltage is the only real answer.

Does a higher supply voltage give a stepper more torque?

It buys torque at speed, not more holding torque. Holding torque is set by winding current, which the driver regulates regardless of supply. At speed, current cannot build fast enough in each step, and a higher supply voltage drives it in faster, so the curve falls off later. This is why the curve must be read at the voltage you will actually run.

Can I fix a stepper torque shortfall with more gear reduction?

Only sometimes, because the fix fights itself. More ratio multiplies joint torque, but for the same joint speed the motor must turn proportionally faster, which moves the operating point down the torque-speed curve where the motor is weakest. Always check motor-side: divide joint demand by ratio and efficiency, then compare with the curve at the resulting motor speed. In the worked example, 20:1 still failed because it pushed the motor to 1200 rpm.

Is a closed-loop stepper just a servo by another name?

No. Closing the loop adds position-loss detection, so the axis can report or correct a stall instead of silently losing steps. It does not change the torque-speed curve or the thermal limits: the copper still has to make the torque at the required speed. A servo drive controls motor current continuously against feedback and is rated for continuous and peak torque separately.

Keep reading

  • Selection guide

    Stepper to Servo Conversion: When It Is Worth Retrofitting

    A stepper-to-servo conversion is feasible but it is an axis-engineering project, not a drive-card swap: sizing, mechanics, feedback, power, command interface and safety all change. If the machine already meets its speeds, repairing the stepper electronics or fitting closed-loop steppers carries less risk; convert when you need speed, acceleration or provable position the steppers cannot deliver.

    Motors, gearboxes and drives sizing

  • Troubleshooting

    Why a Hobby Servo Robot Arm Smokes and How to Fix It

    A smoking joint servo is a thermal overload: the arm's gravity holding torque plus acceleration demand exceeded what the actuator could dissipate, and a stall-torque rating is not a continuous rating. Check supply, binding, current by pose and temperature, then fix the load with a counterweight, reduction or shorter reach before buying a different motor brand.

    Motors, gearboxes and drives sizing

  • Selection guide

    Choosing Servo or Stepper for a 1% Speed Regulation Pinch Wheel

    Pick the servo: behind a 45:1 planetary reducer, a velocity-mode servo meets a 1% wheel-speed tolerance with margin, because 200-300 lb-in at 80 rpm needs only 4.9-7.4 lb-in at the motor and the loop corrects load-induced error. A stepper qualifies only when its torque-speed curve clears the load with margin at the required motor speed and a measured ripple test holds the wheel inside 0.8 rpm.