How-to
Swapping an Identical DRIVE-CLiQ Servo Motor Without Reconfiguration
Short answer
A DRIVE-CLiQ servo motor with the same full order number needs no drive reconfiguration: the motor's electronic rating plate supplies the motor and encoder data at every power-up. Verify all characters of the order number, confirm the actual topology matches the target topology, then fit the spare and re-home the axis, because the machine zero moves with the new encoder zero.

On this page
No. A spare motor with the same full order number and a DRIVE-CLiQ connection needs no drive reconfiguration on a SINAMICS S120 with CU320: the motor stores its motor data, encoder data and identity on an electronic rating plate inside the encoder module, and the drive reads that plate at every power-up and compares it against the commissioned configuration. What the swap does change is the machine zero, because the new encoder's zero does not sit where the old one sat. So the whole job is: read the fault first to confirm the motor really is the problem, verify the complete order number including the option suffix, confirm the actual topology matches the target topology, fit the spare, and re-home the axis before releasing the production cycle.
Read the encoder fault before you swap anything #
An encoder fault on a DRIVE-CLiQ axis does not by itself prove the motor encoder is defective. Read the fault number and its fault value from the drive's diagnostics before touching hardware, and look that exact number up in the S120 list manual. The fault value narrows the cause to a category: lost communication, a faulty signal, an encoder-internal error, or a topology mismatch. Work from the cheapest check to the most expensive:
| Observation | Likely area | Confirming check |
|---|---|---|
| Fault comes and goes, worse when the axis moves or the cabinet door is handled | DRIVE-CLiQ cable, connector latch, shield | Reseat both ends, inspect the latches, compare the LED state on the module and on the motor |
| Fault present at every power-up, component missing from the topology | Cable break, encoder supply, encoder module | Compare the actual topology in the commissioning tool against the target topology |
| Fault follows the motor when it is fitted to another axis | Motor encoder | Move the motor only; keep the cable with the axis |
| Fault stays on the axis with a known-good motor fitted | Cable or Motor Module port | Swap the cable first, then try another DRIVE-CLiQ port |
Swap the motor only after the cable and connectors are ruled out, otherwise the spare inherits the same fault on its first shift.
Why an identical order number needs no drive change #
A DRIVE-CLiQ motor's encoder module carries the electronic rating plate: order number, motor data, encoder data and serial identity. At startup the drive reads the plate and compares the physical component against the commissioned one, at the strictness set by the topology comparison level — the SINAMICS list manual documents the comparison-level parameter p9908 for this. When the order number matches, the motor data set, encoder type and resolution match too, so every parameter you commissioned stays valid and no download is needed.
Because the comparison runs on the order number, the full string matters, not the frame size. If the drive rejects a motor whose order numbers do match, check the comparison-level setting and the connector seating before anything else. Do not switch the topology comparison off to clear the fault: it is the check that catches wiring errors and wrong components, and disabling it hides both.
Comparing the rating plate on a 1FK7060-5AH71-1FG2 spare #
Inputs for this example: the commissioned motor order number from the machine's record is 1FK7060-5AH71-1FG2, and the spare on the bench carries the nameplate 1FK7060-5AH71-1FG2. The rule: every character position must agree, including the option suffix after the last hyphen, because the drive's acceptance test reads the whole string.
The comparison, block by block:
1FK7against1FK7— same synchronous servo family.060against060— same frame size and rated-data block.5AH71against5AH71— same construction and rated-data variant.1FG2against1FG2— same encoder variant and option suffix, so the same DRIVE-CLiQ encoder.
All characters agree, position by position. Result: the spare reproduces the same component data, so the drive accepts it at power-up with no configuration download and no parameter edit. The decision: fit it, clear the faults, and re-home the axis — nothing else.
The contrast case is documented inside the same motor family. An order number such as 1FK7080-2AF71-1PG0 differs at the frame-size positions and ends in a resolver variant instead of a DRIVE-CLiQ encoder, so that motor does not connect to this drive's encoder interface at all, let alone as a drop-in. That is what one changed character can mean.
Replacing the motor #
- Compare the rating plates of the old and spare motors: full order number, encoder variant, brake option. Record both serial numbers.
- Isolate the drive and wait for the DC link to discharge to a safe voltage as the drive's documented safety instructions require before opening anything — the DC link holds a lethal charge after the supply is off. Follow your site's lockout procedure and the machine's risk assessment.
- Disconnect the power, brake and DRIVE-CLiQ connectors, supporting each cable so no strain lands on the connector.
- Fit the spare mechanically. Before bolting it down, check the alignment of a flexible shaft coupling where the motor shaft joins the gearbox or lead screw, and torque the flange screws to the machine drawing.
- Reconnect power, brake and DRIVE-CLiQ using the original cables. Inspect pins and seals, and secure the shield connections.
- Power up the CU320 and Motor Module, go online in the commissioning tool, and confirm the topology view lists the motor encoder component with no mismatch indication.
- Clear and acknowledge the faults. If a topology or component fault comes back, read its fault value and re-check the order number before changing any parameter.
Re-home the axis before production #
The encoder zero of the new motor does not coincide with the old motor's, and the rotor-to-shaft relationship is different too. For an absolute encoder, the absolute value is stored in the encoder, so the machine position reads differently after the swap; for an incremental encoder, the reference is lost at power-off anyway. Either way, the home position and every software limit that depends on it are invalid until you re-reference.
Re-run homing, or the absolute-encoder adjustment, for the axis in the PLC's technology or motion objects, and check the home position against the machine's physical zero mark rather than trusting the number alone — coupling position and drivetrain backlash both move with the new motor. If the axis still stops short of or past the mark after re-referencing, the same feedback-swap logic behind a servo travel error applies, and the article on fixing travel error after swapping a resolver and an encoder walks through it: Fix Servo Travel Error After Swapping Resolver and Encoder.
If you changed any drive parameter during diagnosis, save it to non-volatile memory with the drive's copy RAM to ROM function; otherwise it reverts at the next power cycle.
Verify after the swap #
- Fault buffer: no active encoder or topology faults after power-up and acknowledgement; only older, historic entries remain.
- Topology view: actual topology equals target topology, with the motor encoder listed as a DRIVE-CLiQ component and no mismatch flag.
- Encoder status: position and speed values update smoothly when you turn the shaft by hand, with no jumps or dropouts.
- Low-speed jog in both directions: no following-error or speed-deviation alarm, no vibration, no noise at standstill.
- Homing: repeat the homing run twice and confirm both land on the same position, matching the mechanical mark.
- Persistence: power-cycle the cabinet after saving; the drive returns to ready with no new fault and the axis stays referenced as its encoder type allows.
What is not a drop-in replacement #
- A different option suffix. A variant with a different holding brake, shaft option or encoder type carries different component data and needs a drive configuration update, even in the same frame.
- A different motor type. Fitting an induction motor where a synchronous servo ran is a commissioning task with new motor data, a new control mode and a new encoder setup — not a swap. What actually decides a replacement motor on an existing drive is covered in What Decides Old Servo Motor and New Drive Compatibility.
- A motor without a DRIVE-CLiQ encoder interface. No cable adapter turns it into a drop-in; the drive has to be reconfigured for the new feedback.
When the replacement genuinely is not identical, the drive must be reconfigured and the procedure is different from this one — the knowledge-base walkthrough of the DRIVE-CLiQ encoder reconfiguration procedure covers that case step by step: SINUMERIK ONE DRIVE-CLiQ Encoder Reconfiguration Procedure. For the identical-order-number case this article describes, the answer stays no: verify the plate, confirm the topology, fit the motor, re-home the axis.
Questions asked
Do I need to download motor data to the drive after fitting an identical DRIVE-CLiQ servo motor?
No. The motor and encoder data live on the electronic rating plate inside the encoder module, and the drive reads that plate at every power-up and compares it against the commissioned configuration. The only save worth making is storing any parameter you changed during diagnosis to non-volatile memory with the drive's copy RAM to ROM function, so it survives the next power cycle.
Why does the machine zero shift after the swap when no parameters changed?
The encoder zero of the new motor does not sit where the old motor's did, and the rotor-to-shaft relationship differs too. For an absolute encoder the absolute position is stored in the encoder itself, so the machine position reads differently after the swap even though the drive configuration is untouched. Re-run homing and check the home position against the mechanical zero mark before releasing the axis.
Can I clear a topology fault by switching off the topology comparison?
No. The topology comparison is the check that catches wiring errors, wrong components and a mis-seated DRIVE-CLiQ connector, and disabling it hides all of those while leaving the real fault in place. Read the fault value, re-check the full order number including the option suffix, and verify the comparison-level setting in the list manual instead.
The serial number on the spare differs from the old motor. Does that matter?
No. The drive's comparison is order-number based, so a different serial number is expected and is not a configuration difference. What must match is the complete order number, including the option suffix that identifies the encoder variant and the holding brake. If those characters all agree, the spare reproduces the same component data and the drive accepts it unchanged.