Short answer

Yes, two servos can raise one 900 lbf fixture — gear both real axes to one virtual master, trip a cross-axis position fault that halts the master when either side strays, watch the two motor currents separately, and counterbalance each side so the holding brakes stop drifting the level away. Identical independent commands are not synchronization.

On this page
  1. Gear both real axes to one virtual master
  2. Supervise the split, not just each axis
  3. Split the load and check the current
  4. Counterbalance and fail-safe brakes
  5. Commissioning procedure
  6. Worked example: drift budget and fault limits for a 900 lbf two-servo lift
  7. Questions asked

Yes — two servo actuators can raise one 900 lbf fixture, provided they share a single motion reference and are supervised against each other. Commanding both drives to the same target is not synchronization: the two moves merely coincide. A homing offset on one axis, unequal following error, a brake that releases late, or a fault on one drive opens a position split that racks the fixture across its rails while each axis still follows its own command perfectly.

The architecture that works: one virtual master axis carries the motion profile, both real lift axes gear to it, a cross-axis position fault halts the master if either side strays, the two motor currents are watched separately, and counterbalance on each side keeps the holding brakes from drifting the level away cycle by cycle. The procedure below commissions it.

Gear both real axes to one virtual master #

A virtual axis is a commanded position with no motor behind it. Put every move, jog and home profile on it, then electronically gear each physical lift axis to it. At a 1:1 ratio a geared axis reproduces the master's motion exactly: command the master 100 mm and each lift travels 100 mm. If the two sides ever differ mechanically, such as different screw leads, the per-axis gear ratio absorbs the difference — but on a lift the hardware should be identical at 1:1, so the position split means something.

Use a virtual master rather than naming one real axis the master. A faulted real master leaves the healthy slave geared to a dying axis with nothing left to command a clean stop. With a virtual master, a fault on either real axis halts the one reference, and both lifts stop together on the same profile edge; continuing to drive the healthy side after the other trips is what turns a drive fault into structural racking.

The follower side of that relationship is the same gearing used when following a master axis with a stepper traverse; the difference here is that the master drives no motor and both followers carry the load.

Supervise the split, not just each axis #

Two supervisions are needed, and neither substitutes for the other.

Per-axis following error — each axis's commanded position minus its actual — you set tight, as on any servo axis. It catches a drive struggling to track its own command.

Cross-axis error is the position of lift A minus the position of lift B, sign-corrected so both count the same physical direction, and offset by the level reference recorded at commissioning. Compute it in the controller from the two actual positions, not by subtracting two displays. This is the supervision that matters on a twin-axis lift, because two axes can each sit inside their following-error windows while holding a mechanical offset between them: a homing difference, a slipping coupling, one brake dragging. Neither axis faults, and the fixture racks anyway.

Supervise load the same way. Motor current tracks torque, so on a symmetric machine the two currents should match in every regime: constant-speed up, constant-speed down, acceleration, deceleration, standstill. A difference that grows at standstill means one side is carrying the other through the frame. A current that is acceptable during a short acceleration says nothing about continuous or RMS thermal loading — check both against the drive's ratings.

Split the load and check the current #

With the fixture's weight centered between two identical actuators, the static share is 900 lbf ÷ 2 = 450 lbf per actuator. That is the starting assumption, not the sizing answer: acceleration force, friction, screw efficiency, an off-center center of gravity and frame stiffness all move the real peaks, and each of them lands on whichever side is momentarily stiffer.

For each screw, estimate motor torque as T = F × L ÷ (2π × η), where F is axial force in lbf, L is screw lead in inches per revolution and η is drivetrain efficiency, giving torque in lbf·in. Take L and η from the datasheet of the exact screw; a borrowed lead or a generic efficiency is how one side of a twin-axis lift gets undersized. Add acceleration force to F, and subtract the counterbalance force only in the direction it assists — then check the descent separately, because an over-pressured counterbalance loads the down-move instead of helping it. The per-side arithmetic is the single-axis routine covered in how to choose servo gearing for a ballscrew router axis; what is new on a lift is the shared reference and the split supervision.

Counterbalance and fail-safe brakes #

Vertical axes that get disabled every cycle — light curtain broken, axis braked, repeat — creep on the motor holding brakes alone. On comparable machines the reported behavior is a few thousandths of an inch per disable, accumulating 0.050 to 0.100 in after about a dozen interruptions: the level walking away one interlock at a time.

A counterbalance cylinder removes most of that. Its force is regulated pressure times effective piston area; regulated so that force matches each side's static share, the fixture is near weight-neutral and the brakes hold almost nothing. Set it from the motors, not the gauge: at slow constant speed the current magnitude should be nearly equal up and down, because only friction remains when the cylinder matches the weight, and at standstill both motors should sit near zero torque and read symmetrically. Know what it is not: cylinder friction, supply-pressure drift and geometry all move its force, and it does nothing for left-right alignment. It is load reduction; the servo coordination still owns the synchronization.

On a load this size, put the mechanical fail-safe brakes rigidly on the screws themselves, not downstream of a reducer, belt or chain — anything between the brake and the load is a failure the brake cannot arrest.

Commissioning procedure #

  1. Support the fixture on rated blocks and apply the machine's lockout and stored-energy procedure before any step that releases torque; treat stop-and-hold as a safety function rated to the performance level the machine's risk assessment assigns under ISO 13849.
  2. Verify the mechanics first: identical screw leads, sound couplings, matched travel direction and scaling, and the fail-safe brakes proven on the screws. Both axes must report the same engineering units and sign for the same physical direction.
  3. Tune each axis on its own first — the single-axis method in tuning a servo axis with a 6:1 ballscrew inertia ratio — with the fixture supported so neither axis fights the other, then trim the gains with both running.
  4. Create the virtual master and move every commanded profile onto it, then gear both real axes to it at 1:1.
  5. Configure any drive fault or following-error trip on either real axis to halt the virtual master immediately, so both lifts stop on one edge.
  6. Level the fixture mechanically against a reference measured at both lift points, and record the feedback difference at that level. That recorded number is the synchronization offset the cross-axis error is measured against.
  7. Set the per-axis following error tight, then set the cross-axis position fault from the drift budget below.
  8. Use absolute encoder position as the primary restart reference where the feedback supports it, and add a controlled re-home or alignment routine that verifies both sides agree before normal motion is released.
  9. Permit relative correction moves only during commissioning or recovery, at limited velocity, while watching the split and both currents; a fast correction can twist the fixture faster than the guides absorb.
  10. Trim the counterbalance from measured current with the up/down symmetry check, then confirm the lift stays controlled on the descent, where the cylinder is helping the load down.
  11. Run at reduced speed first, then raise speed and acceleration while logging the position split, both motor currents, following error and brake behavior every cycle.

Worked example: drift budget and fault limits for a 900 lbf two-servo lift #

Inputs: fixture weight 900 lbf, the machine under design; two identical actuators with the load centered, so the static share is 900 ÷ 2 = 450 lbf per side; reported brake drift on comparable brake-only vertical axes of 0.050 to 0.100 in over about 12 disable cycles, a field observation rather than a bench test; and a few thousandths of an inch total drift with counterbalance — read as no more than about 0.005 in per side over the same 12 cycles.

The rule in words: each holding brake can let its side creep in either direction, so the worst-case split grows by the sum of both sides' drift at every disable cycle.

Arithmetic at the reported worst end: per side per disable, 0.100 in ÷ 12 ≈ 0.008 in (the low end gives 0.050 ÷ 12 ≈ 0.004 in). Worst-case split per disable is 0.008 + 0.008 = 0.016 in. Over 12 cycles, 0.016 × 12 ≈ 0.19 in — the same picture as 0.100 in of creep on each side in opposite directions. With counterbalance the budget is 0.005 + 0.005 = 0.010 in across all 12 cycles.

Decisions: fit the counterbalance on both sides, because it is the difference between roughly 0.016 in of new split at every disable and about 0.010 in across a dozen. Set the cross-axis position fault at 0.050 in and make the trip force a re-level and re-home before normal motion resumes; that limit catches the split within about three worst-case brake-only cycles, since 3 × 0.016 in ≈ 0.048 in. With counterbalance fitted, treat any sustained split above 0.010 in as a fault rather than drift — a slipping coupling, a dragging brake, or lost air pressure. This is a calculated budget for these inputs: if a one-time commissioning measurement shows the guides binding at a smaller skew than 0.050 in, lower the fault to the measured value.

Questions asked

Why do identical position commands fail to synchronize the two servos?

Because the two commands share no reference. A homing offset on one axis, unequal following errors, a brake that releases late, or a fault on one drive each open a position split while both axes still track their own commands. The giveaway is a fixture that loses level with no following-error fault on either drive. Gearing both real axes to one virtual master fixes the reference, and the cross-axis position fault enforces it.

How far apart should the two lift positions be allowed to get?

On a lift of this class, trip the cross-axis fault at 0.050 in. The trip halts the virtual master, and normal motion stays locked out until the fixture is re-leveled and the offset re-recorded; that limit catches the split within about three worst-case brake-only disable cycles, since 3 × 0.016 in ≈ 0.048 in. With counterbalance on both sides, treat a sustained split above 0.010 in as a fault, not drift.

Does a counterbalance cylinder replace the holding brakes?

No. It unloads the motors and brakes and removes most of the per-cycle drift, but its force moves with regulated pressure, cylinder friction and geometry, and it does nothing for left-right alignment. If the air supply drops, the load it was carrying returns to the brakes at once, so supervise the pressure as part of the lift, and keep a mechanical fail-safe brake for gravity rigidly on the screw.

Could one servo and the guide rails carry the lift instead?

The rails constrain posture but do not remove the moment of lifting from one side; the guide bearings take a cantilevered load they may not have been sized for, and one screw plus one brake carries everything. If you want that layout, calculate the guide moments and frame deflection explicitly before committing. At 900 lbf, two driven, supervised lift points is the stronger architecture.

How do I know the counterbalance pressure is set right?

From the motors, not the regulator gauge. Jog slowly up, then slowly down at constant speed: when the cylinder matches the weight, current magnitude is nearly equal both ways, because only friction remains. If anything, trim slightly under weight-neutral, since an over-balanced cylinder pushes the load down and shows up as higher descending current. At standstill both motors should sit near zero torque and read symmetrically.

Keep reading

  • Troubleshooting

    Why a Servo Axis Runs Away During Tuning

    A servo that completes its commanded move, then throws itself into reverse at full speed while the velocity command has no effect, has a feedback fault: reversed encoder direction, or open, crossed or noisy encoder wiring. Uncouple the motors, verify feedback polarity and continuity with the drive disabled, then retune from default gains. Raising gains cannot fix positive feedback.

    Servo and stepper motion

  • Troubleshooting

    Fix Servo Travel Error After Swapping Resolver and Encoder

    Travel that does not match the position display after a resolver-to-encoder swap is a scaling fault: the drive or the technology axis is still converting counts with the other feedback's increments per revolution. Measure one commanded move and divide actual by displayed travel; a constant ratio equal to the resolution ratio names the encoder data. Fix both layers, re-home, then re-tune.

    Servo and stepper motion

  • Troubleshooting

    Servo Motor Rear Noise: Brake or Bearing, Not Gears

    Rear servo noise under the resolver cover is the spring-applied 24 V brake or the rear bearing, and the motor holds bearings, not gears. Verify brake release under electrical load first: brake drag shows up as current rise, heat and noise tied to release events, while bearing noise tracks shaft speed and survives a brake proven healthy.

    Servo and stepper motion