AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Explainer

Synchronous vs asynchronous servo motors and drive use

Servo and stepper motion Published 8 min read By AutomateDirectUSA engineering team

Short answer

Servo means closed-loop feedback control, not a motor construction: a synchronous servo is a permanent-magnet AC motor, an asynchronous servo is a squirrel-cage induction motor in servo service. No drive can be assumed to run both, so verify drive support for the motor construction and for the feedback device as two separate checks before you buy or couple anything.

On this page
  1. What is the difference between a synchronous and an asynchronous servo motor?
  2. What does servo mean if it is not a motor type?
  3. Can one servo drive run both motor types?
  4. What feedback does each construction need?
  5. How much slip does an asynchronous servo have at rated load?
  6. Can an asynchronous servo hold position or crawl at low speed?
  7. How do I bench-verify a drive and motor pair?
  8. Which construction should I choose?
  9. Questions asked

Servo names the control loop, not the motor: a synchronous servo is a permanent-magnet AC machine, an asynchronous servo is a squirrel-cage induction machine doing servo work, and a drive cannot be assumed to run both. The two checks that decide everything are drive support for the motor construction and drive support for the feedback device, made separately. This page gives you the construction difference, the speed arithmetic that shows it, the feedback each rotor needs, and a bench procedure to confirm a drive and motor pair before you couple it to the machine.

What is the difference between a synchronous and an asynchronous servo motor? #

A synchronous servo is a permanent-magnet AC motor whose rotor locks to the stator field with zero slip; an asynchronous servo is a squirrel-cage induction motor whose rotor always runs slower than that field by the slip it needs to make torque.

In the synchronous machine the rotor carries permanent magnets, so its flux is built in and the rotor tracks the stator's rotating field exactly, at any speed the drive commands, including standstill. Torque is set by the angle between field and magnets, which is why the drive must always know where the magnets are. In the asynchronous machine the rotor is a squirrel cage of bars shorted at each end: the rotating field induces currents in those bars, and only the difference between field speed and rotor speed sustains those currents and the torque. No slip means no rotor current and no torque. Siemens and SEW Eurodrive catalogs both file servomotors under these two headings, which is where the terms usually reach a new servo user.

Property Synchronous servo Asynchronous servo
Rotor Permanent magnets, flux built in Squirrel-cage bars, current induced by slip
Slip Zero, rotor speed equals field speed Needed for torque; a few percent of field speed at rated load, taken from the datasheet
Torque per frame size High Lower, so a larger frame for the same torque
Drive must provide Commutation from rotor position Slip and flux regulation, closed by feedback
Standstill Holds continuous stall torque as rated Needs forced cooling for continuous torque

What does servo mean if it is not a motor type? #

Servo names the control method: a controller measures position or speed with feedback and keeps correcting until the error is zero, no matter which motor turns the shaft.

A conveyor started across the line stops somewhere near where you hoped; a servo axis measures where it stopped and moves until it is where you commanded. The actuator is interchangeable: brushed DC, permanent-magnet AC, induction, rotary or linear, even hydraulic. The feedback is interchangeable too, and industrial axes mostly use incremental and absolute encoders and resolvers while smaller systems use potentiometers. The feedback choice shapes the drive interface more than the motor does, and the same loop logic underlies does an encoder make a stepper motor closed loop on the stepper side of the shop.

Can one servo drive run both motor types? #

Not unless the drive's own documentation lists both constructions and your feedback device: treat motor-type support and feedback support as two separate decisions, because a power stage that runs induction motors is not proof it can commutate a permanent-magnet rotor.

The control jobs differ. On an induction machine the drive regulates flux and slip, which is vector control, and can start from an encoder on the shaft. On a permanent-magnet machine the drive must commutate: aim the stator current at a fixed angle to the magnets, which requires rotor position from feedback or from an estimator inside the drive.

So the default answer is no. Some servo drives list both an asynchronous vector mode and a synchronous PM mode, and those run either motor; a plain open-loop volts-per-hertz inverter is an induction-motor product and will not commutate a PM rotor. When the motor already exists and the drive is what you are replacing, start from the feedback device and work forward, the way selecting a replacement servo drive for resolver motors does. Decision: write the motor construction and the feedback type on one line, and confirm both appear in the drive's supported list before you wire anything.

What feedback does each construction need? #

A synchronous servo needs rotor position for commutation, from a resolver or an absolute encoder; an asynchronous servo needs shaft speed, usually an incremental encoder, to close the vector control loop.

On the PM machine, what matters is absolute rotor angle at power-up. A resolver gives that angle within one revolution and shrugs off heat and vibration; an absolute encoder gives it plus multi-turn counts; an incremental encoder gives pulses only, so the drive must run a commutation alignment or estimation at start. On the induction machine the feedback is speed: closed-loop vector control of an induction motor with a shaft sensor is long-established drive practice, and the encoder is usually a simple incremental type.

Feedback retention decides your startup. A device that does not hold absolute position through a power loss, such as plain incremental encoders or resolvers beyond one turn, leaves the axis needing a homing move before anything position-dependent runs. The drive must also physically read the device, and the signal names and formats have to match, which is the whole subject of matching encoder signal names between motor and servo drive.

How much slip does an asynchronous servo have at rated load? #

At 60 Hz and four poles the rotating field turns at 1800 rpm: a synchronous servo's rotor sits at exactly 1800 rpm at any load, while an induction rotor runs 1746 rpm at the 3 percent rated slip used in this example.

Inputs: pole count p = 4, drive output frequency f = 60 Hz, rated slip s = 0.03. The slip is an example input typical of small induction machines; take the real value from the datasheet of your exact motor.

Field speed: n_s = 120 × f / p = 120 × 60 / 4 = 1800 rpm.

Rotor speed: n = n_s × (1 − s) = 1800 × (1 − 0.03) = 1800 − 54 = 1746 rpm.

Rotor current frequency: f_r = s × f = 0.03 × 60 = 1.8 Hz, the actual frequency of the currents induced in the cage bars.

This is a calculated example for those inputs, not a measurement. The decision it supports: at the same four poles and 60 Hz, the synchronous rotor needs no trimming because its speed is set by commanded frequency and pole count alone, while the induction rotor trades those 54 rpm for its torque, and slip grows as load grows. Two constructions, two control laws, which is exactly why drive support is construction-specific.

Can an asynchronous servo hold position or crawl at low speed? #

Yes, but only with closed-loop vector control and real cooling: the shaft fan on an induction motor moves almost no air at crawl speeds, so continuous torque at low speed or standstill needs forced ventilation, while a permanent-magnet servo is rated for continuous stall torque.

Torque from slip has a thermal cost: at standstill delivering full torque, the slip frequency is the full supply frequency and rotor losses are at their worst, with a fan that is standing still. Drive application notes report many drives cannot usefully regulate an induction machine below roughly 90 rpm, while permanent-magnet machines are routinely driven to near 0 rpm; those are reported figures, not a law, and the continuous-torque-versus-speed curve in your motor datasheet under its stated cooling method is what decides.

If you are converting a line-fed induction motor to converter supply, use one identified for that duty: NEMA MG-1 Part 31 in North America or IEC 60034-25 internationally. In plain words, both require the motor's insulation and thermal design to accept the fast voltage edges and harmonic-rich current a drive imposes. Then budget the blower.

How do I bench-verify a drive and motor pair? #

Enter the nameplate data, run the motor uncoupled at restricted speed, confirm that a commanded positive move produces positive feedback and that the loop shrinks the error rather than chases it, then cycle power to see whether position survives or the axis must home.

  1. Set the drive's motor data from the nameplate, and run the drive's motor-identification routine if it offers one.
  2. With the motor uncoupled and speed limited, jog in the positive command direction and watch the feedback count: it must increase. If it decreases, fix the feedback direction with the setting that kind of drive provides before anything else.
  3. Watch the loop settle: the axis should reach position and hold without oscillating around it.
  4. Cycle control power: an absolute system comes back on position, anything else needs its homing sequence before production moves.
  5. Run the intended low-speed duty and check the motor's temperature; correct rotation proves commutation, not thermal margin.

Lock out the drive and confirm its DC bus is discharged before touching motor leads: a spinning permanent-magnet rotor generates voltage at the terminals even with control power off.

Which construction should I choose? #

Pick permanent-magnet synchronous for compact, fast, high-torque axes and true standstill holding; pick asynchronous servo where the axis is large, the duty is coarse, the environment is hot or dirty, and a bigger frame is acceptable.

Tight envelope, fast index-and-return cycles, holding against gravity: synchronous. Large torque, hot and dirty plant air, long coarse moves at modest speed: asynchronous, with the cooling decided up front. Retrofit with an existing induction motor: make it an asynchronous servo by adding an encoder and a closed-loop vector drive, using a motor identified for converter supply. Salvage or unknown motor: identify the construction and the feedback device first, then buy the drive that lists both.

The construction sets the physics, and the drive must match it twice, once for the motor type and once for the feedback. The servo behavior you actually came for comes from the loop, whichever rotor is inside.

Questions asked

Why do servo catalogs split motors into synchronous and asynchronous?

Because the split names the rotor, not the loop. Expect synonyms as well: the same permanent-magnet synchronous machine is sold as PMSM, PMAC or brushless AC servo, and the induction machine as an AC asynchronous servo. Whatever the label on the catalog page, the drive decision stays the same: match the construction and the feedback device separately.

Can a standard VFD run a permanent-magnet synchronous servo motor?

Only when the drive documents a permanent-magnet motor mode, which uses feedback or an internal rotor-position estimator to commutate. A plain volts-per-hertz inverter has no way to aim its current at the magnet angle, so the rotor will not synchronize under load. Treat PM motor support as a listed feature, never as a default.

Does an induction motor become a servo just by adding a drive?

No. Without shaft feedback you have a variable-speed drive, not a servo. It becomes a servo axis when a closed-loop vector drive uses an encoder on the shaft to regulate speed or position, and even then its low-speed torque is limited by cooling, not by the control loop.

How can I tell the construction if the nameplate is missing?

Rotate the shaft by hand with the motor disconnected: a permanent-magnet rotor gives distinct cogging detents as its magnets pass the stator teeth, while a squirrel-cage induction rotor spins freely and silently. Then identify the feedback device and its wiring, because construction plus feedback is the pair of facts every drive choice needs.

What happens when the drive supports the motor but not the feedback device?

The drive will either reject the motor or fall back to a lesser mode, sensorless or speed-only, losing absolute position and low-speed torque. Signal converter boxes between feedback formats exist, but the sounder decision is a drive that lists your feedback device natively.

Keep reading

  • Selection guide

    Selecting a Replacement Servo Drive for Resolver Motors

    Screen the resolver interface before the power ratings: excitation frequency and voltage, transformation ratio between 0.2 and 1 V/V, pole relationship, pinout, and whether the resolver carries commutation. Then check the supply input range and continuous current against the motor nameplate. For a 1.3–1.5 kW axis the current screen passes easily; the resolver match decides the drive.

    Servo and stepper motion

  • Comparison

    Servo or Stepper for Fast Start-Stop Feed Rollers

    At 28 in feeds and 100 bags/min, a 2 in roller peaks near 1,337 RPM with about 1,400 rad/s² of angular acceleration; through the 5:3 belt drive the motor sees about 2,230 RPM. That is deep in the torque cliff where a hybrid stepper keeps only a fraction of its low-speed torque and loses steps silently, so this machine takes a servo.

    Servo and stepper motion

  • Troubleshooting

    Why a Servo Motor Oscillates Between Two Positions

    A servo that hunts in a stable 30-50 degree band and restarts on a light shaft nudge has a working position loop running on wrong motor or load data. Fix the configuration — engineering units, load description, pole count, resolver excitation — before swapping phases or retuning: in the documented case, converting metric values into the drive's lbf-ft fields and correcting the load entry stopped it.

    Servo and stepper motion