AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

How-to

Syncing an Indexing Conveyor With a Web Using Electronic Gearing

Servo and stepper motion Published 8 min read By AutomateDirectUSA engineering team

Short answer

Make the indexing conveyor the master and the web drive the follower, tied by one ratio: (web advance per index × follower pulses per mm) ÷ (conveyor advance per index × master pulses per mm). With a 150 mm index at 40 pulses/mm and a 120 mm web advance at 25 pulses/mm, it is 3,000 ÷ 6,000 = 0.5. The follower counts measured master pulses, so the web stays locked through accel and decel; at one to two cycles per minute, lag is not a constraint.

On this page
  1. Why one motor and belts is not the default
  2. What the follower actually locks to
  3. Compute the ratio from pulses per mm
  4. Choose the drive architecture
  5. Set up and verify the follower
  6. Diagnose drift at the seal station
  7. Questions asked

Make the indexing conveyor the master and the web drive the follower, tied together by one gear ratio:

ratio = (web advance per index × follower pulses per mm) ÷ (conveyor advance per index × master pulses per mm)

For a 150 mm conveyor index at 40 pulses/mm and a 120 mm web advance at 25 pulses/mm, that is (120 × 25) ÷ (150 × 40) = 3,000 ÷ 6,000 = 0.5 follower pulses per master pulse. The follower counts the master's measured pulses and multiplies them by that ratio, so web position tracks conveyor position through acceleration and deceleration, and at one to two cycles per minute there is no lag penalty to design around. Mechanical lineshafts, twin independent profiles and open-loop steppers each fail this job for specific reasons; the sections below give the decision, the arithmetic and the verification procedure.

Why one motor and belts is not the default #

One motor, timing belts and pulley ratios driving both axes exists as a machine architecture, but it only holds while the web advance per index is a fixed multiple of the conveyor pitch. Every seal-length or product change then means new pulleys or change gears, and the ratio cannot be trimmed while running. Belt backlash and web compliance also make the calculated surface speed differ from the real web advance, and a mechanical train has no way to correct that difference.

Two independent motion profiles started at the same instant fail differently. Each axis runs its own accel, run and decel, so start-signal jitter, different drive tuning and different loads all land as position error at the seal station, and because nothing compares the two axes, the error accumulates index after index.

Open-loop steppers on both axes are the weakest choice for this machine: a stepper that loses steps does it silently, and the loss is cumulative and invisible to the controller.

What the follower actually locks to #

Electronic gearing is pulse counting. The follower drive receives the master's encoder or pulse train on its input, multiplies the incoming count by the configured ratio, and generates its own position command; drive documentation describes follower mode as a ratio of the follower's internal counts to incoming pulses. If the master signal is a true measure of conveyor position, the web's commanded position is a fixed multiple of the conveyor's actual position at every instant, accel and decel included, which is what removes the start-time and tuning mismatches.

The weak link is what the master count represents. An open-loop stepper master that forwards its own commanded pulses keeps producing pulses when the conveyor jams or stalls, and the web keeps feeding into the stoppage. The master must therefore be a servo, or a stepper whose encoder output — measured motion, not commanded steps — feeds the follower.

One more property follows from the same mechanism: the follower derives its velocity and acceleration from the master, so noise on the master line is exaggerated in the follower's motion. Run the master signal differential and shielded, and set the follower's encoder input mode to match the sender's output. If the master motor reaches the conveyor through a belt reduction, mounting a motor encoder behind a belt reduction covers where the encoder belongs so the follower measures real conveyor motion.

Compute the ratio from pulses per mm #

Each axis's pulses per mm come from the drive's command resolution divided by the linear travel per motor revolution. Example scaling: a drive set to 10,000 command pulses per revolution on an axis advancing 5 mm per revolution gives 10,000 ÷ 5 = 2,000 pulses/mm, and one command pulse then equals 5 ÷ 10,000 = 0.0005 mm. Travel per revolution is roller or pulley circumference divided by the mechanical reduction, and any internal electronic gearing in the drive is already included in the command-resolution figure.

Inputs for the calculated example, chosen to show the method:

  • Conveyor advance per index: L_conv = 150 mm
  • Master scaling: PPM_conv = 40 pulses/mm
  • Web advance per index: L_web = 120 mm
  • Follower scaling: PPM_web = 25 pulses/mm

Master pulses per index = 150 mm × 40 pulses/mm = 6,000 pulses. Follower pulses per index = 120 mm × 25 pulses/mm = 3,000 pulses. Ratio = 3,000 ÷ 6,000 = 0.5, entered as the fraction 1/2 where the drive accepts a numerator and denominator, or 0.5 where it takes a decimal. Both length inputs must share one unit, the ratio itself is dimensionless, and it does not move with cycle rate; change the index length or the seal length and recompute.

Choose the drive architecture #

Architecture How the web follows Pick it when
Follower-mode drive with encoder input Master encoder wired into the follower's input; ratio set in the drive Fixed ratio, minimal wiring, no per-product trim
Servo master forwarding pulses to a servo follower The master drive's pulse output feeds the follower's pulse input More torque and positioning margin than steppers; ratio still fixed in the drives
Motion controller commanding both axes The controller generates both pulse streams; a gear instruction applies the ratio only, a follow instruction applies the ratio and corrects follower position against the master Product or seal-length changes, or any need to trim web position relative to the conveyor

Decision path: with a fixed ratio and a product that holds its own registration, wire drive to drive and stop there. The moment seal length or product mix can change, or web slip must be trimmed out, put a motion controller on both axes and use the instruction that applies the ratio and corrects follower position — setting up servo electronic gearing with registration correction walks that path. Step up from steppers to servos when torque margin or positioning resolution, not cost, is the binding constraint. Drive-side lineshaft software goes further: Yaskawa's electronic lineshaft manual for G7 drive software (document TM.G7SW.064) documents a ratio adjustable while running plus a draw trim added to the follower's speed reference.

The same follower hookup runs any second slave on the machine — following a master axis with a stepper traverse uses the identical wiring and ratio logic.

Set up and verify the follower #

  1. Lock out the machine and release web tension before wiring or jogging either axis; in US practice that energy-control procedure is the one OSHA 29 CFR 1910.147 requires your site to maintain, and the seal and die-cut hazards belong to the machine's risk assessment.
  2. Configure the master's index: length, accel ramp, decel ramp, repeatability. The follower can only be as repeatable as the master, so settle the master first.
  3. Wire the master signal to the follower — encoder output into the follower's encoder input, or the master servo's forwarded pulses into the follower's pulse input — differential and shielded, with the follower's input mode matched to the sender.
  4. Scale both drives and record the two pulses-per-mm figures from the configuration, not from memory.
  5. Enter the ratio as an exact fraction where the drive accepts one. Use the gear-only instruction if the ratio is the whole requirement; use the follow-and-correct instruction if web position must be trimmed against the master.
  6. Static check: inhibit the follower, jog the master slowly, and confirm the follower's displayed position count stays at zero. A creeping count is noise on the input — fix the wiring before going further.
  7. Slow index, web unloaded: run one index and measure the web advance against the calculation, then 100 indexes and check the total (100 × 120 mm = 12,000 mm). Drift in the total means ratio rounding or master slip.
  8. Production check: load and tension the web, raise the index speed and ramps to production values, and watch seal-to-part position over at least 100 cycles.

Diagnose drift at the seal station #

Observation at the seal or die-cut station Likely cause, cheapest first Confirming check
Seal offset grows a little every index Ratio slightly wrong or rounded Recompute from both axes' pulses per mm; compare the master's commanded count with its encoder count over one index
Offset jumps once, then holds Master lost steps, or a belt or roller slipped Compare master command count with encoder count over one index
Offset differs between short and long indexes Web stretch or nip slip under accel Lengthen the decel ramp; check web tension and the nip
Web creeps while the conveyor stands still Noisy or floating master input into an enabled follower Watch the follower's count with the master stationary; check shielding and input mode

Rounding deserves its own arithmetic because it accumulates. Suppose the true ratio were 3,000 ÷ 6,001 = 0.49992 and the drive stored the decimal 0.4999. The per-index error is (0.5 − 0.4999) × 6,000 pulses = 0.6 pulses, which at 25 pulses/mm is 0.6 ÷ 25 = 0.024 mm per index — enough to cross a ±0.5 mm seal tolerance in 0.5 ÷ 0.024 ≈ 21 indexes. That is a calculated example for those inputs, not a measured drift rate. Entering the exact fraction, choosing drive scaling so the ratio is a clean number, or using the follow-and-correct instruction removes the accumulation.

Decision for this machine: conveyor as master, web drive as follower, one ratio. A stepper follower with an encoder input when the budget is tight and the product list is one; a controller with the follow-and-correct instruction from day one if seal length or product will ever change; a servo master the day the conveyor can jam faster than an operator can react. At one to two cycles per minute, lag will not be what fails this machine — the ratio, an unmeasured master and web slip will be.

Questions asked

Does the gear ratio change when the machine runs faster?

No. The ratio depends only on the two advance lengths and the two pulses-per-mm figures, so speeding the machine up leaves the 0.5 ratio untouched; what changes is torque demand and tuning. Recompute only when the conveyor pitch or the web advance per index changes. A machine running several seal lengths belongs on a controller that stores a ratio per recipe, or on a drive that switches between stored ratios from a digital input.

The follower twitches while the conveyor is stopped. What is that?

Usually noise or a floating master input. The follower derives its velocity and acceleration from the master, so it amplifies whatever sits on that line, and an enabled follower with the master unpowered can count induced pulses on a floating input. Inhibit the follower whenever the master is off, confirm the encoder input mode matches the sender's output type, differential or single-ended, and land the cable shield at one end only.

Can the web run slightly faster than the ratio to stay taut?

Yes, and that trim has a name: draw. Lineshaft drive software lets the ratio be adjusted while running and adds a draw percentage to the follower's speed reference on top of the geared speed, so the follower leads the pure ratio by a fixed amount. Set draw from web behavior, not from calculation: raise it until the web no longer bags between indexes, then stop there.

How tight can registration be before I need a mark sensor?

Electronic gearing holds the commanded relationship exactly as long as the master measures real motion, but it cannot see slip between the drive roller and the web, and that slip, not the gearing, sets the floor. If the seal-to-part tolerance is tighter than the nip can repeat under production tension, plan a registration-mark sensor feeding the follow-and-correct input from day one; retrofitting it later means rebuilding the control architecture.

Keep reading

  • How-to

    Setting Up Servo Electronic Gearing With Registration Correction

    Gear the folder servo to the web encoder with one fixed electronic gear ratio and apply registration error as a bounded phase trim ramped across the 100 to 200 ms between corrections. At 150 m/min a 0.1 mm tolerance is 40 microseconds of web travel — about eight 0.0127 mm increments — so doubling or halving a pulse train for six pulses trips following error, while a ramped trim changes speed by 0.04 percent.

    Servo and stepper motion

  • How-to

    Synchronizing Two Servo Axes on One Heavy Lift

    Yes, two servos can raise one 900 lbf fixture — gear both real axes to one virtual master, trip a cross-axis position fault that halts the master when either side strays, watch the two motor currents separately, and counterbalance each side so the holding brakes stop drifting the level away. Identical independent commands are not synchronization.

    Servo and stepper motion

  • How-to

    Aligning aantry at Startup With Absolute Encoders

    No, homez1,2 references each axis to its own absolute feedback; it does not align the two motors to each other. Square the beam with a skew measurement, record the follower-minus-leader position offset, and at every power-up jog the follower by the computed correction with the leader held on J/ before running homez1,2, or reference the leader and initialize the follower coordinate from the stored offset instead.

    Servo and stepper motion