AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Explainer

What Decides Hydraulic Cylinder Positioning Accuracy in Metal Spinning

Pneumatics and hydraulics Published 7 min read By AutomateDirectUSA engineering team

Short answer

An integrated position sensor makes a hydraulic cylinder a measurable axis, not a precise one. Accuracy in thick-sheet spinning is set by valve response and hysteresis, the unequal cap and rod-end areas, seal friction and frame compliance. Size the force first, fit a valve whose response matches the move, and verify the tolerance at the tool.

On this page
  1. The sensor measures the cylinder, not the sheet
  2. Sizing the force for a 63 mm bore at 160 bar
  3. Why the same valve command gives two speeds
  4. Servo valve or proportional valve
  5. Where the accuracy is actually lost
  6. Proving the axis before the first sheet
  7. The decision, case by case
  8. Questions asked

A position sensor built into the hydraulic cylinder makes the axis measurable, and for thick-sheet spinning hydraulics are the right force source. The open question is whether the axis is precise, not just powerful, and the sensor does not decide that. Accuracy is decided by the valve's response and hysteresis, by the unequal cap-end and rod-end areas, by seal friction, and by how much the frame and tooling deflect under the forming load. Work in that order: compute the force first, choose a valve whose dynamics fit the move, then prove the tolerance at the tool with no sheet in the machine. This article walks the decisions and the arithmetic in the order they should happen.

The sensor measures the cylinder, not the sheet #

An integrated transducer reports piston position relative to the cylinder body. It cannot see the rod bending under the forming load, play in a linkage, deflection of the tooling and frame, or thermal growth, and the tolerance in spinning applies at the roller-to-sheet contact, not at the piston.

Treat the sensor as necessary but not sufficient. Before any tuning, sweep the axis slowly through the full stroke and confirm the displayed value moves smoothly, monotonically and in the right direction to both endpoints, with scaling and polarity checked against the sensor and the analog input documentation. Those checks are the same ones that decide a 4-20 mA cylinder loop; they are worked through in Path control of a hydraulic cylinder with 4-20 mA feedback.

Then measure the gap between the cylinder reading and the tool position with a dial indicator or a laser sensor at the work point, loaded as in production. If that gap exceeds the process tolerance, the fix is stiffness and geometry — rod, tooling, slides, linkages — not controller gain.

Sizing the force for a 63 mm bore at 160 bar #

The inputs, both example values for this calculation and not measurements from a machine:

  • Bore: 63 mm, a standard metric cylinder size; take the real value from the cylinder datasheet.
  • Pressure: 160 bar at the cap-end port, the kind of setting a relief valve holds under forming load; take the real value from the pump's relief setting.

The rule in words: the force a cylinder delivers is the supply pressure times the effective piston area of the driving chamber.

The arithmetic:

  • Piston area: A = π d² / 4 = 3.1416 × (63 mm)² / 4 = 3117 mm² = 31.2 cm²
  • Pressure conversion: 1 bar = 10 N/cm², so 160 bar = 1600 N/cm²
  • Force: F = 1600 N/cm² × 31.2 cm² = 49,920 N ≈ 49.9 kN

That is about 49.9 kN at the piston, a calculated example for those two inputs, not a measured machine result. The rod-end return pressure subtracts through the smaller annulus and seal friction takes a further slice, so expect somewhat less at the sheet.

The decision: if the forming force you compute for the sheet exceeds what this example delivers, grow the bore by the square root of the force ratio. Doubling the force at the same pressure means doubling the area, from 31.2 cm² to 62.4 cm², and √2 × 63 mm gives a bore of about 89 mm. No valve, controller or gain setting creates piston area, so size the bore for force before anything else. The same area-and-pressure arithmetic on a different machine is worked in Sizing a Hydraulic Cylinder Bore for a Linked Lift.

Why the same valve command gives two speeds #

A double-acting cylinder has a different effective area on each side: the rod occupies part of the bore, so the rod-end annulus is smaller than the full piston area. The consequences are mechanical, not tuning problems. The same flow moves the piston faster toward the rod end than away from it, in the ratio of full-bore area to annulus area. The same pressure delivers more force extending than retracting, by that same ratio. And the forming load itself often helps one direction while resisting the other, so the controller sees a different plant each way.

A single fixed-gain PID tuned on extension will be wrong in retraction, sluggish or over-responsive depending on the load. You need gains scheduled by direction, or a motion controller built for hydraulic axes that models the two chambers and the load explicitly. This asymmetry is the main reason a hydraulic spinning axis behaves less intuitively than an equivalent ball-screw servo; Can a PLC Servo Valve Stop a Hydraulic Ram Repeatably shows what the closed loop has to get right.

Servo valve or proportional valve #

Both families meter flow in proportion to the command signal. They differ in exactly what this job cares about: a servo valve is built with internal feedback for tight hysteresis, fast response and good repeatability, while a general-purpose proportional valve trades dynamic performance for simpler construction and usually has larger hysteresis, a wider null deadband and slower step response.

Make the choice from datasheets, not labels. Take the valve's published hysteresis and step-response time, convert hysteresis to a position error through the valve gain, and compare both against the move profile and the tolerance band. A working rule: if the valve's hysteresis alone eats more than about a quarter of the position band, that valve is out. If a proportional valve's published figures fit the move and the band, it can serve; if they are missing or miss, you are at a servo valve, and no amount of PID work recovers a bandwidth or deadband limit. The roller reverses under load at the end of every pass, and the moment of flow reversal decides whether material piles up or thins at the turn, which is why the response figures are the whole game here.

Metering losses are a separate accounting: a pressure drop across the valve does not by itself reduce cylinder force, as worked through in Why a valve pressure drop does not reduce cylinder force. For what a servo-valve ram axis achieved on a comparable positioning job, see How Accurate Is Hydraulic Servo Valve Ram Positioning.

Where the accuracy is actually lost #

Work this list from the cheapest check to the most expensive fix before blaming the controller:

  • Feedback scaling, polarity and resolution. A software check: sweep slowly and watch for jumps, backward steps or saturation at the endpoints; confirm the resolution against the tolerance.
  • Valve hysteresis and null deadband. Command small equal steps toward and away from a mid target; the split in achieved position by approach direction is the hysteresis and deadband appearing as position error.
  • Seal breakaway friction. Stick-slip shows as a staircase response at tiny commands. Seals chosen to hold pressure are often the wrong choice for fine motion; cylinders intended for positioning duty get low-friction seal sets, and re-specifying them is routine when a machine is converted to closed-loop positioning.
  • Structure compliance. Measure tool position loaded and unloaded; the difference is deflection, fixed with rod diameter, tooling and slides — not with gain.
  • Direction-dependent areas and load. The asymmetry described above, visible as good behavior one way and poor behavior the other.

Proving the axis before the first sheet #

You do not have to turn sheet into scrap to learn whether the axis holds position. Set the feedback scaling, sweep the stroke, command small manual steps, then run the controller's auto-tune if it has one. Expect the excitation to shake the machine hard. A hydraulic axis holds stored energy, so block or restrain the slide, drop the pressure to what the test needs, and work to the machine's risk assessment and lockout practice.

Then measure at the tool. Command the same target ten times from each direction and record the spread with an indicator: that spread, not the sensor's resolution, is the positioning accuracy. Repeat with the tool loaded as in production, because the forming load is part of the loop. If the spread sits inside the process tolerance with margin, run the sheet. If it does not, the answer is in the loss list above — feedback, valve, seals, structure — not in more gain.

The decision, case by case #

  • Force. Compute pressure times bore area at the relief setting before anything else. The example inputs give about 50 kN; if the sheet needs more, bore up by the square root of the force ratio — the doubling case needs about 89 mm — or raise pressure only within the cylinder's rating.
  • Valve. Decide from the datasheet: hysteresis converted to position error must fit inside about a quarter of the band, and step response must fit the move. Figures published and fitting, a proportional valve can serve; missing or missing the mark, a servo valve.
  • Feedback. Keep the integrated sensor and verify at the tool under load. A gap beyond tolerance at the tool is a stiffness and seal problem, so fix the structure, not the gains.
  • Control. Schedule gains by direction or use a motion controller made for hydraulic axes; the PLC's auto-tune is the right starting point, run with no sheet in the machine.

Questions asked

Will a hydraulic axis hurt the surface finish of the spun sheet?

Not by itself. Surface finish comes from the stability of roller force and feed speed during the pass, not from the position sensor. If marks or ripples appear where the pass reverses, suspect valve hysteresis, null deadband or seal stick-slip rather than the position loop. Keep pressure and flow steady and tune for smooth velocity, not just endpoint accuracy.

Does a larger bore make positioning more accurate?

No. The bore sets force, not accuracy: at 160 bar a 63 mm bore delivers about 50 kN, and growing the bore mainly adds oil volume that must be metered, which slows the axis. Accuracy comes from valve response and hysteresis, seal friction, feedback quality and frame stiffness. Size the bore for the force the sheet needs, then spend the effort on valve and structure.

What position feedback resolution does the axis need?

As a rule of thumb, feedback resolution about ten times finer than the tolerance you must hold: a target of plus or minus 0.1 mm wants a sensor reporting steps of 0.01 mm or less. Resolution is not accuracy, though. The sensor must also repeat and be scaled correctly; command the same target from both directions and record the spread at the tool to see the accuracy you actually have.

Why does the cylinder run faster retracting than extending on the same command?

The rod side has less effective area because the rod occupies part of the bore. With the example bore and, as an example dimension, a 45 mm rod, the annulus is about 31.2 minus 15.9 = 15.3 cm2, so the same flow retracts roughly twice as fast as it extends and delivers about half the force. The controller needs different gains in each direction.

Keep reading

  • Explainer

    Can a PLC Servo Valve Stop a Hydraulic Ram Repeatably

    No — not on a PLC analog output alone. Oil compressibility, load and valve null drift move an open-loop stop, so the loop must close on a ram-mounted transducer, which a Delta Motion note says can position heavy loads to better than 0.0005 in. Decide by measuring today's stopping spread against the part tolerance: if the stop switch meets it, modernize the servo positioner and keep the manual fallback.

    Pneumatics and hydraulics

  • Explainer

    How Accurate Is Hydraulic Servo Valve Ram Positioning

    A 4-20 mA servo valve command does not by itself determine ram position accuracy. Complete closed-loop systems with linear transducer feedback and PLC PID have held about 1 mm; the valve datasheet alone specifies hysteresis, null behavior and repeatability, not machine accuracy.

    Pneumatics and hydraulics

  • How-to

    PID control of a ±10 V proportional valve from a PLC

    Run the valve from a PID loop whose signed output is clamped to -100% to 100% and scaled linearly so +100% gives +10 V and -100% gives -10 V. Derive cylinder speed from the linear transducer, command speed as a curve of stroke position, and start the stop deadband at 2 mm so the valve does not chatter at target.

    Pneumatics and hydraulics