What decides robot joint encoder resolution you can measure
Short answer
Robot builders rarely publish tick counts for a joint encoder, and where a joint fuses an absolute encoder with an incremental channel, one tick count cannot describe the reported angle anyway. The deciding quantity is the angular step at the joint output, 360/2^n degrees for an n-bit absolute sensor, and you can measure the effective step by logging reported joint angles and taking the smallest consistent difference between distinct values.

On this page
Ask a robot builder for the tick count of a joint encoder and the documentation comes back empty, because most builders do not publish one. Where a joint pairs an absolute encoder with an incremental channel and the controller fuses the two, a single tick count would not describe the position value your program reads anyway. The quantity that decides the case is the angular step at the joint output: step = 360/2^n degrees for an n-bit absolute sensor. That step you can measure directly, by logging the joint angles the controller reports and taking the smallest consistent difference between distinct values. This article gives the formula, a documented encoder example with the arithmetic, the measurement procedure, the standard that judges repeatability, and the decision for each case.
The joint step, not the tick count #
Ticks per revolution is an intermediate number. What the application feels is the step the joint can express, and for an absolute sensor with n bits per revolution it is:
step_deg = 360 / 2^n
step_rad = 2π / 2^n
A 20-bit sensor divides one revolution into 1,048,576 counts and a 19-bit sensor into 524,288. At the tool center point the angular step becomes a linear step:
linear_step ≈ step_rad × r
where r is the perpendicular distance from the joint axis to the TCP. That product is a lower bound on how finely the joint can place the TCP. It excludes gear backlash, joint compliance, thermal growth and calibration error, and those dominate the achieved positioning, which is why the builder's pose repeatability figure, tested under ISO 9283 (the standard that defines how pose repeatability is measured across defined poses and payloads), is the number that judges the robot. The encoder step judges only the position value.
What an encoder datasheet actually documents #
Off-axis absolute magnetic rotary encoders are the sensor class used inside compact robot joints, where a ring and a read head fit in the joint housing without contact. RLS's AksIM-2 family is a documented example of that class, named to identify the datasheet rather than as a confirmed part of any particular robot. The family datasheet page lists the MB039 at 19-bit and the MB053 at 20-bit resolution, with an accuracy of ±0.05°, a maximum speed of 10,000 rpm and repeatability finer than one step of the resolution.
Worked example, calculated for these inputs, taking the 20-bit variant:
- joint step: 360 / 1,048,576 = 0.000343°
- in radians: 2π / 1,048,576 = 5.99 × 10^-6 rad
- at an example lever arm r = 0.8 m: 5.99 × 10^-6 rad × 0.8 m = 4.79 × 10^-6 m, about 0.0048 mm at the TCP
The 19-bit variant gives 360 / 524,288 = 0.000687°, about 0.0096 mm at the same arm. Those are the finest steps the sensor can express.
Resolution is not accuracy. The same document's ±0.05° accuracy is 0.05 × π / 180 = 8.73 × 10^-4 rad, which at that arm is ±0.70 mm, about 145 times coarser than the 20-bit step. Quoting a bit depth as a positioning capability therefore overstates it by two orders of magnitude. And unless the robot builder documents the exact part installed, a family datasheet is only a capability ceiling: gearing, scaling and any fusion in the controller all sit between the ring and the reported angle.
Why one tick count cannot describe a fused pair #
An absolute encoder reports position within one revolution as soon as power is applied, with no homing move, which is the property that lets absolute joint encoders feed a stepper arm without homing. An incremental channel resolves finer but loses its reference when unpowered. Pair the two and the controller can fuse a coarse absolute reading with a fine relative one, holding absolute reference and fine resolution in a single reported angle.
The fused value can resolve finer than either sensor's raw tick spacing, or it can be limited by the coarser channel at power-up. Which behavior applies lives in the controller's processing, not in a datasheet. So the useful question is never how many ticks the encoder has but how finely the reported joint angle changes, and the second question has a measurement.
Measure the step your program actually sees #
- Write the requirement down: the smallest motion the application must command or detect at the TCP, in millimeters or degrees. Often the written requirement is coarser than any plausible encoder and the tick-count question ends there.
- Convert it to a joint step at the worst case: step_rad = s / r, with s the required linear motion and r the longest lever arm from that joint's axis to the TCP.
- Stream the joint angles the controller reports, over its real-time data interface, at a fixed rate. Keep the robot stationary with the servos holding and everyone outside the safeguarded space while it is powered; this measurement is not a safety validation.
- Log several thousand samples per joint.
- Sort the distinct values and take the difference between each pair of neighbors. The smallest difference that repeats consistently is an upper bound on the reported quantization step.
- Jog the joint very slowly and repeat the analysis, because noise on a stationary joint can hide steps that a slow jog exposes.
- Compare the measured step with the required step from step 2; a margin of several times is typical practice, since quantization is one error source among many.
- If the design depends on the sensor specification itself, ask the builder's official support channel in writing, with the requirement and the machine's identification; some builders provide it under a non-disclosure agreement.
Choosing the bit count for a joint you build #
When you are building the axis instead of characterizing one, invert the formula. From a required TCP step s at lever arm r:
n ≥ log2(2π × r / s)
Worked example: the requirement is 0.1 mm of TCP motion at a 0.5 m lever arm.
- required joint step: 0.1 × 10^-3 m / 0.5 m = 2.0 × 10^-4 rad
- counts needed: 2π / 2.0 × 10^-4 = 31,416 counts per revolution
- 2^14 = 16,384 counts is short; 2^15 = 32,768 counts covers it
Fifteen bits is the minimum, and sixteen is the sensible choice: 65,536 counts give a joint step of 0.00549°, exactly twice the margin of the bare minimum.
| Bits | Counts per revolution | Joint step | TCP step at r = 0.8 m |
|---|---|---|---|
| 16 | 65,536 | 0.00549° | 0.077 mm |
| 17 | 131,072 | 0.00275° | 0.038 mm |
| 19 | 524,288 | 0.000687° | 0.0096 mm |
| 20 | 1,048,576 | 0.000343° | 0.0048 mm |
Every TCP column is a calculated example for that 0.8 m arm, and the 19-bit and 20-bit rows are the documented depths of the two AksIM-2 variants above. The same counts-versus-resolution arithmetic on a linear axis is worked out in encoder line count for a servo ball screw axis, and the matching problem between resolution and the motion an axis must follow, in choosing encoder resolution to match a stepper step response.
Pitfalls that skew a measurement #
- The reported angle is a converted floating-point number, not a raw count. The discrete steps you see in it come from the controller's processing chain, which is the right thing to measure because that number is what the motion program consumes, but do not present it as the sensor's tick count.
- A stationary joint with noise can look continuous. Jog slowly and repeat; if the spread of values exceeds a few steps after warm-up, you are watching thermal settling or servo behavior rather than quantization.
- The Cartesian step grows with reach: the same joint step is a larger linear step with the arm extended, so characterize the worst pose.
- Do not transfer a result between joints or between models; measure each axis.
- Record the controller software version with the result, because a firmware change can alter how the fused angle is produced.
The decision, case by case #
- Characterizing an existing robot: the smallest consistent difference between logged distinct joint angles is the resolution the motion program has; design against it with a margin of several times over the required TCP motion, and if the margin goes negative, the axis cannot express the requirement.
- Specifying or certifying the sensor: only the builder's written data for the exact installed part is valid; a family datasheet such as the AksIM-2 example gives a ceiling and an accuracy class, 19 or 20 bits and ±0.05° in that document, never the joint's number.
- Building a joint: n ≥ log2(2π × r / s), round up and add at least one bit of margin; the 0.1 mm at 0.5 m example lands on sixteen bits.
When the reported step rather than the sensor turns out to be the limit, the fix is in the controller's scaling and fusion chain or in an external measurement, not in a tick count nobody publishes.
Questions asked
Does the measured joint step tell me the robot's repeatability?
No. The measured step says only how finely the reported position value can change. Repeatability is judged from the pose repeatability figure the builder publishes, tested under ISO 9283, and it includes gearing, joint compliance and thermal effects. Quote the builder's repeatability figure for positioning capability, and the measured step only for what your motion program can express.
Can I get the real tick count from the robot builder?
Yes, by asking. Send your written accuracy requirement and the machine's identification to the builder's official support channel and request the per-joint encoder data; some builders provide it under a non-disclosure agreement. That written answer is the only valid source for the sensor specification. The step measured from logged joint angles remains the quantity your application actually needs.
Two identical robots give different measured steps. Why?
Matching steps on two machines point to a design property; differing steps point to measurement noise, a different joint hardware revision or different controller software. Let both robots warm up, log at the same rate, and record the software version with each result. If one machine still disagrees, treat its measurement as unreliable instead of designing around it.
How much margin should I leave over the measured step?
Typical practice is a margin of several times between the required motion and the measured step, because quantization is only one error source in the chain. If your required TCP motion equals the measured step, the axis cannot express it reliably: relax the requirement at that reach, add an external measurement, or get the builder's written position specification.