AutomateDirectUSAMotion LibraryIndustrial monitors & PCs

Explainer

What Drive End and Clockwise Mean in Servo Encoder Adjustment

Sensors, encoders and machine vision on the machine Published 7 min read By AutomateDirectUSA engineering team

Short answer

The end code printed as DS in the adjustment sentence is the drive end — DE in the motor documentation's abbreviation list — the end that carries the output shaft. Clockwise is judged looking along the shaft from that end toward the motor body; from the opposite end the same motion reverses. The disconnected power cable removes the supply, not the voltage: the terminals stay live whenever the shaft turns.

On this page
  1. The sentence fixes a viewpoint, a direction and a supply state
  2. Resolving DS: the abbreviation list and outline drawing decide
  3. Where the drive end is and what clockwise means from it
  4. Driven, not energized: why the power cable comes off
  5. The disconnected cable is not a dead cable
  6. What the measurement actually sets
  7. The decision, end to end
  8. Questions asked

The end code printed as DS in that adjustment sentence is a viewing-end designation: the end of the motor you observe from, not an electrical connection. In the servo documentation for this procedure the drive end is abbreviated DE, so DS is best read as a misprint of it — and the drive end is the end that carries the output shaft. Clockwise then means: stand at the shaft end, look along the shaft toward the motor body, and turn the shaft the way a clock's hands move from that position. The power cable comes off because the measurement must run with the motor unenergized, not because the terminals go dead — a spinning permanent-magnet rotor generates voltage at them. Resolve the code against your motor document's abbreviation list and outline drawing before anything turns.

The sentence fixes a viewpoint, a direction and a supply state #

Siemens publishes this adjustment step for its synchronous servo motors — for example, the operating instructions for the SINAMICS S210 drive system and its 1FK2 servo motors carry it. The sentence that raises the question reads: "For the measurement, the motor must be driven in a clockwise direction as seen from the DS with the power supply cable disconnected."

Three separate requirements sit in that one sentence. A viewpoint: the rotation is judged as seen from a named motor end. A direction: clockwise from that viewpoint. A supply state: the power supply cable is disconnected while it happens. Nothing in the sentence says how the encoder connects for the measurement, how fast to turn the shaft, or what the accepted result looks like; the rest of the same procedure carries those, and this article resolves the part engineers actually stall on — which end, and which way.

Resolving DS: the abbreviation list and outline drawing decide #

As printed, the code is DS; a hand-retyped copy of the sentence may carry DC instead, which reads like a supply type and is not one. The code the servo documentation defines is DE, drive end. The drive end is the motor end that transmits torque to the load — the output-shaft end, with the shaft seal and mounting flange. The opposite end is the non-drive end, NDE, where these motors usually carry the encoder and, on larger frames, the cooling fan. Older motor-industry shorthand even calls the shaft end the back end and the opposite end the front end, the reverse of what the words suggest to a newcomer — one more reason the document, not vocabulary, settles it.

Two documents settle the code: the abbreviation list and the outline drawing in the manual covering your exact motor and encoder family. If the list defines DE and has no DS entry, the printed DS is a misprint. If the list does define DS, use the end its drawing marks. Nothing else substitutes for that check — not the encoder's location, not the drive's positive-speed sign.

Code Stands for How to treat it here
DE Drive end, the end that transmits torque to the load The reading to test first; the observation point
NDE Non-drive end, the opposite end where the encoder usually sits Not the observation point unless your document names it
DS The code as printed in the adjustment sentence Unresolved until your abbreviation list or drawing confirms it
DC The code in hand-retyped copies of the sentence A retyping artifact, not a DC supply requirement

Worked reading, with example document contents: the abbreviation list defines DE, drive end, and NDE, non-drive end, and has no DS entry; the outline drawing labels the shaft-flange end DE. Decision: read the sentence as clockwise as seen from the drive end and put the observation point at the output shaft. If your own list instead defines DS and marks an end for it on the drawing, that end becomes the observation point and the clockwise rule is unchanged.

Where the drive end is and what clockwise means from it #

On the floor, the drive end identifies itself: it is the end with the output shaft. Stand on that side and sight along the shaft axis toward the motor body. Clockwise is the clock-hands direction seen from that position. Walk around to the non-drive end and the same shaft motion runs counterclockwise — direction carries no meaning until a viewpoint is fixed, which is exactly why the sentence fixes one. The encoder sits at the non-drive end on most of these motors, and its location does not move the reference: the named end is for your eyes, not for the encoder.

Do not take the direction from the drive's positive-speed convention instead. Electrical direction depends on how the axis is parameterized and how the feedback is wired; the sentence references a physical viewpoint precisely so it does not depend on any of that. And driven means the shaft is made to rotate by an external means — the full procedure states the means and the shaft speed it wants, and the quoted sentence gives neither, so take both from the procedure rather than assuming hand rotation either way.

Driven, not energized: why the power cable comes off #

The measurement reads the encoder's signal while the shaft turns mechanically, so the motor must not be energized through its power cable at the same time — that is what the disconnected cable buys, and why driven cannot mean run the drive. The power cable and the encoder measurement connection are separate circuits: disconnecting the power cable says nothing about the encoder connection, which the complete procedure specifies, including any supply the measurement interface needs.

The disconnected cable is not a dead cable #

A permanent-magnet servo rotor is a magnet assembly. Turn the shaft by any means and the motor generates a sinusoidal voltage at its terminals, power cable connected or not; the magnitude rises with shaft speed, and shorted terminals drive real current. Disconnection separates the motor from its supply — it does not make the terminals voltage-free. Follow your site's lockout practice under its hazardous-energy standard (in the US, 29 CFR 1910.147), verify absence of applied voltage at the terminals before touching them, and keep the disconnected cable ends and the motor terminals shrouded for as long as the shaft can turn. The machine's risk assessment governs the details.

What the measurement actually sets #

A servo encoder reports rotor position, and in a permanent-magnet synchronous axis the drive commutates against that position — it times stator current to the rotor's magnetic poles. Replacing the encoder resets the relationship between its reported counts and the pole position; a perfectly seated encoder can still be electronically wrong. The measurement re-establishes the relationship and stores the result with the motor identification, the same step described in commissioning a replacement servo encoder with motor ID data.

Run it from the wrong end and the stored relationship is flipped. The drive may reject the result at acceptance, or keep it and enable the axis with wrong commutation: humming, overcurrent trips, reversed or absent torque. That failure surfaces as the alarms covered in troubleshooting an absolute encoder status alarm on a servo drive and, after a rebuild, in fixing a grid align error after a servo motor rebuild.

The decision, end to end #

  1. Open the abbreviation list and outline drawing of the manual for your motor and encoder family and confirm the end code they define; DE is the code to expect, and whatever the list defines is the code you use.
  2. Find that end on the physical motor: the drive end is the output-shaft end.
  3. Fix your observation point there, sighting toward the motor body; the encoder's location does not move it.
  4. Disconnect the motor power cable under your lockout procedure, verify absence of applied voltage, and shroud the cable ends and terminals, which carry generated voltage whenever the shaft turns.
  5. Connect for the measurement exactly as the full procedure specifies, including the rotation means and shaft speed it states; the quoted sentence is preparation, not the method.
  6. Turn the shaft clockwise as seen from the named end, take the measurement and store the result per the procedure.

Decisions per case: if the abbreviation list defines DE with no DS entry, read the printed DS as DE and watch from the shaft. If the list defines DS, use the end its drawing marks; the clockwise-from-that-end rule is unchanged. If neither document resolves the code, stop and settle it with the manufacturer's documentation before rotating — with the viewpoint unresolved, the direction is a coin flip, and a flipped direction defeats the adjustment.

Questions asked

Is DS a misprint of DE in the encoder adjustment instruction?

Treat it as a misprint of DE until your own document says otherwise. The servo documentation for this procedure defines DE as the drive end and NDE as the non-drive end; DS is not a code those documents spell out. Check the abbreviation list and outline drawing in your motor's manual: no DS entry plus a drawing that marks the shaft end DE means you read the sentence as clockwise as seen from the drive end.

Does clockwise reverse when you stand at the non-drive end?

Yes. Direction only means something once a viewpoint is fixed. The same shaft motion that looks clockwise from the drive end looks counterclockwise from the non-drive end, which is why the instruction names the end it does. It is also why the encoder's own position, usually at the non-drive end, does not set the reference: you look from the named end, wherever the encoder sits.

Why disconnect the power cable if the measurement is electrical?

The measurement reads the encoder, not the power terminals, and it must not run while the drive energizes the motor. The shaft has to be turned by an external means instead, which is what driven means in the sentence. Disconnecting the power cable separates the motor from its supply; the encoder connection the measurement needs is specified separately in the same procedure.

What happens if the adjustment runs with the wrong viewing direction?

The measurement records the encoder position against the wrong rotor position, so the stored relationship is flipped. Depending on the drive, the result is either rejected at acceptance or kept, and the axis then enables with wrong commutation: humming, overcurrent trips, reversed or absent torque, and absolute-encoder or grid-align alarms. Fixing it means repeating the measurement with the shaft genuinely clockwise from the named end.

Can the motor terminals really be live with the power cable off?

Yes. A permanent-magnet servo rotor is a magnet assembly; turning the shaft induces voltage at the motor terminals even with the supply disconnected, and the magnitude rises with shaft speed. Disconnection removes the applied supply, not the generated voltage. Keep the cable ends and terminals shrouded, verify absence of voltage before touching them, and treat them as live whenever the shaft can rotate.

Keep reading

  • Troubleshooting

    Troubleshooting an Absolute Encoder Status Alarm on a Servo Drive

    The alarm has two documented triggers: the encoder failed its internal status check, or the encoder turned faster than its rated speed after control power was applied. Work from the cheapest check to the decisive one: cable and connector integrity, encoder supply voltage measured under load, shaft motion in the power-on window, then drive settings. Replace the encoder only when all of those pass and the alarm still returns.

    Sensors, encoders and machine vision on the machine

  • How-to

    Matching Encoder Signal Names Between Motor and Servo Drive

    Matching capability labels do not prove a motor and drive will talk. Map the sine and cosine pairs by function, then resolve index, data and clock and the commutation definition from both datasheets into a function-based cable schedule, because the connectors will not match pin for pin.

    Sensors, encoders and machine vision on the machine

  • Troubleshooting

    Servo Drive Encoder Phase Alarm: Isolate Wiring, Encoder or Drive

    An encoder phase error alarm means the drive is not receiving A and B as clean square waves 90° apart, and the cable is the most common cause. Check in order of cost — connections, waveforms on a scope, encoder mounting, drive parameters — then decide encoder versus drive by substitution: the fault that follows the encoder condemns the encoder; the fault that stays with the drive condemns the drive's feedback input circuit.