Why a Closed Loop Stepper Is Louder Than a Servo

Servo and stepper motion Published 6 min read By AutomateDirectUSA engineering team

Short answer

A closed-loop stepper is louder at standstill because its drive never rests: the current chopper keeps holding current flowing and the position loop rocks the rotor over a few encoder counts. A servo at rest with a light load commands almost no torque current, so it stays quiet. Quiet it with switching frequency, idle current and loop gain settings, because the noise is control behavior, not a motor-type law.

On this page
  1. Where the standstill hiss comes from
  2. The position loop adds a second sound
  3. What one encoder count is worth on the machine
  4. Microstepping sets the command rate, not the noise
  5. Tell the two sounds apart in a minute
  6. Settings that quiet a closed-loop stepper
  7. When to keep the servo
  8. Questions asked

A closed-loop stepper is usually louder at standstill because its drive never rests. Holding position takes continuous current in the windings, chopped at a switching frequency that becomes audible when it sits below about 20 kHz, and the position loop keeps nudging the rotor back and forth across a few encoder counts to cancel error. A servo at rest under a light load commands almost no torque current and corrects in far finer increments, so there is little left to radiate as sound. That makes the difference a control and amplifier behavior, not a law of motor type: you can quiet a closed-loop stepper with switching frequency, idle current and loop gain settings, and you can make a servo whistle by mistuning it the other way.

Where the standstill hiss comes from #

A stepper holds position the hard way: torque comes from current in the windings, and the drive keeps that current flowing whether the load is pushing or not. The drive regulates it with a fast electronic switch, the current chopper, and the resulting ripple makes the windings and stator iron deflect magnetically at the chopper frequency. That is the sound you hear.

Documented stepper noise practice puts a number on it: noise with the motor stopped occurs mainly at switching frequencies below 20 kHz, and human hearing ends near 20 kHz, so a chopper inside the audible band is a hiss that carries across the shop. A squealing stepper is rarely a mechanical grinding issue; the noise is electrical, from the chopping and the magnetic excitation it drives.

The position loop adds a second sound #

Closing the loop mounts an encoder on the shaft and asks the drive to cancel position error, and it never reads exactly zero. Cogging, friction and load disturbances leave an error of typically a few encoder counts, so the loop keeps applying corrective torque and the rotor physically rocks back and forth across them. Each reversal swaps winding current between directions, and the torque step behind a movement measured in micrometres is what buzzes through the motor, the bracket and the machine sheet metal.

This also explains why a closed-loop stepper never reaches a true zero-current standstill: the position demand keeps the amplifier working. The gains that decide how hard the loop chases those counts are the ones behind why a phantom closed-loop stepper still needs PID gains; loosen them and the hunt stops, at the price of the few counts of standstill accuracy you stopped chasing.

What one encoder count is worth on the machine #

Worked example, calculated for these inputs only: a 1000-count-per-revolution encoder on a 5 mm-lead ballscrew. One count equals 5 mm ÷ 1000 = 0.005 mm = 5 µm of carriage motion, so a dither of ±3 counts is ±15 µm. The displacement is invisible; the full-current torque reversals producing it are not, and they repeat at the loop's correction rate, which is what your ear registers.

The same encoder on a belt axis travelling 40 mm per motor revolution gives one count = 40 mm ÷ 1000 = 0.04 mm = 40 µm, and ±3 counts is ±120 µm. Before doing this arithmetic on your machine, read the encoder resolution convention from the datasheet of the exact motor, because a "1000" rating can mean lines or counts and the two differ by a factor of four. The decision: if ±15 µm at standstill sits well inside the process tolerance, treat dither purely as an acoustic problem, not an accuracy one.

Microstepping sets the command rate, not the noise #

Microstepping divides the command pulse train into finer increments; it does not change the encoder resolution or the chopper frequency, so it does nothing for standstill hiss. What it costs is pulse rate. At 2000 microsteps per revolution and 1000 RPM the command source must deliver 2000 × 1000 ÷ 60 ≈ 33,333 steps per second (calculated example, assuming one command pulse per microstep); dropping to 1000 microsteps per revolution halves that to about 16,667 steps per second.

Confirm the controller sustains the rate at full speed; running a step-and-direction axis this way is covered in tuning a pulse-and-direction stepper in closed loop. Microstepping does reduce noise while moving, by smoothing torque ripple and damping low-speed resonance. It is simply silent on the standstill problem.

Tell the two sounds apart in a minute #

Two checks, cheapest first. Change the standstill (idle) current setting and listen: hiss that scales up and down with winding current is the chopper. Then widen the drive's count-based position tolerance, the in-position window or deadband whatever the configuration tool calls it: a buzz that stops when the tolerance widens is loop dither. Both can be present at once, so fix the one that moved.

Settings that quiet a closed-loop stepper #

  1. Raise the switching frequency to or above 20 kHz where the drive exposes it, moving the chopper tone out of the audible band. On a fixed-frequency drive this option does not exist; go to the next item.
  2. Enable idle current reduction so the drive drops winding current to a fraction of run current after a standstill timeout; hiss falls with the current. The confirming check: with the reduced current active, try to move the axis by hand at the load. If it back-drives or stalls, the setting is too aggressive for that load. One safety rule: never apply standstill current reduction or auto-disable on a vertical or gravity-loaded axis unless the mechanism self-locks, because that changes what holds the load, and it belongs in the machine's risk assessment.
  3. Loosen the position loop: lower the proportional gain and widen the count tolerance. In machine units, widening from 1 to 4 counts on the 5 mm, 1000-count example above accepts ±20 µm at standstill instead of ±5 µm. If the process tolerates that, this is the most effective fix for dither buzz.
  4. Cut the structure-borne path. The buzz is often the bracket and sheet metal radiating rather than the motor body; an isolated motor mount or a stiffer bracket changes what the machine sends into the room.

When to keep the servo #

If standstill quiet is a requirement, an operator-adjacent station, a lab or a medical environment, keep the servo. A closed-loop stepper buys low-speed torque, stall recovery and simpler commissioning, not silence: with default settings expect hiss, and after the four changes above expect less, but the loop still never fully rests while enabled.

If you are converting for torque or stall immunity, take the closed-loop stepper and budget commissioning time for the settings above, comparing sound at standstill and during the real motion profile; a phone sound-level meter at the operator position is a rough but adequate before-and-after tool. Judge neither motor type by a badly tuned example, because a mistuned servo can out-whine a settled stepper. The broader economics of swapping motor families are laid out in when a stepper-to-servo conversion is worth retrofitting; run the same math in reverse for a servo-to-stepper change.

Questions asked

Is a closed-loop stepper always louder than a servo?

No. Servo axes also whistle at standstill when the current-loop switching is audible or the position loop is tuned so tightly that it hunts. The difference is typical, not physical law: a stepper drive holds position with continuous winding current, while a servo commands only the torque the load asks for. Judge the specific drive and its tuning rather than the motor type, but expect a default closed-loop stepper to need adjustment before it matches a servo at rest.

Does lowering the idle current risk anything?

It cuts holding torque along with the noise. After the drive drops to its idle setting, push the axis at the load and confirm it holds; the classic failure is a leadscrew axis that stalls or creeps once the reduced current cannot carry the static load. On a vertical or gravity-loaded axis, treat any standstill current reduction or auto-disable as a change to the holding means and clear it against the machine's risk assessment first.

What step rate does 2000 microsteps per revolution need at 1000 RPM?

About 33,333 steps per second: 2000 steps per revolution times 1000 revolutions per minute, divided by 60 seconds per minute. That assumes one command pulse per microstep. Halving the microstep setting to 1000 halves the demand to roughly 16,667 steps per second, so check what the controller can sustain at full speed before raising microstep resolution.

Does a 1000-line encoder give 1000 counts per revolution?

No. Quadrature decoding yields four counts per line, so 1000 lines is 4000 counts per revolution. On a 5 mm-lead screw that changes one feedback count from 5 µm to 1.25 µm, and a three-count dither from 15 µm to under 4 µm. Read the resolution convention from the datasheet of your exact motor before converting counts into machine units.

Does a higher-resolution encoder reduce the dither?

In machine units, yes. The loop still corrects a few counts, but each count is a smaller angle, so the physical rocking and the torque reversals behind it shrink. Going from 1000 to 4000 counts per revolution cuts one count on a 5 mm-lead screw from 5 µm to 1.25 µm, and it lets you hold tighter before hunting starts. Match the encoder to what the drive accepts before changing it.

Keep reading

  • Explainer

    Why a Phantom Closed Loop Stepper Still Needs PID Gains

    With MI910 set to 8, the axis feeds back the accumulated count of pulses its own channel generated, so the loop error - commanded position minus that count - is a real, nonzero signal the PID terms use to drive the pulse frequency modulator. Keep the documented internal-loop stepper values for Ixx30-Ixx35 and Ixx68, set Ixx34 to the documented integration mode for this output, and verify travel independently.

    Servo and stepper motion

  • Troubleshooting

    Why an EtherCAT CSP Stepper Axis Enables but Does Not Move

    Holding torque on Servo On proves only that the power stage energizes the windings. In cyclic synchronous position mode the axis moves only when the drive accepts each new 0x607A target and no internal limit refuses it, so check Statusword bit 11 first, then the drive's speed, current and software position limits, then the position unit scaling between controller and drive.

    Servo and stepper motion

  • How-to

    Tuning a Closed-Loop Stepper With Linear Scale Feedback

    Commission the axis open loop first, verify both linear scale channels and the counts-per-unit constant with gains at zero, then close the loop at an integral gain near 0.01 with about 100 Hz filtering. Backlash, stiction and compliance end up inside the loop, so it limit-cycles at rest — fix the mechanics and the gains together.

    Servo and stepper motion