Troubleshooting
Why Constant Hydraulic Friction Is Often a Pressure Drop
Short answer
A constant offset of 25 bar at both a 130 bar and a 180 bar load is not mechanical friction, because friction moves with load. It is a measured pressure drop, and the constant value points to flow loss through a line or fitting, static head between the gauges, or two readings taken in different states. Find the segment that loses pressure while oil flows before replacing any valve.

On this page
You read the same 25 bar of 'friction' at a 130 bar load and again at a 180 bar load, and the number refuses to move. That refusal is the diagnosis. Sliding friction follows the normal force, so a loss that stays identical while the load rises was never mechanical friction: it is a pressure difference between two measurement points. The constant value points to one of three causes — oil flowing through a line, fitting or valve; the two gauge points sitting at different heights; or two readings that were not taken in the same operating state. All three are cheaper to check than any replacement valve. This article separates the symptom from the physics, works one line-loss calculation to show how little a healthy line loses, and ends with the decision for each measurable pattern.
What the two gauges were actually reading #
A pressure difference is only defined once its two ports are named. Find the hydraulic schematic, identify the pressure measurement points between the pump and the cylinder, and mark them. If there is no schematic, trace and label the lines by hand before comparing any two readings.
Both readings must come from the same operating state, observed at the same moment: same direction of travel, same flow condition (oil moving or holding), same oil temperature. A difference measured while oil flows cannot be compared with one taken at standstill, and the two gauges should be of the same type, rated for the circuit pressure, and zero-checked against each other at one common source.
A load is a force in newtons, not a pressure; the load converts to a gauge reading only through the effective area, and on a plunger cylinder that area is the full ram face, single-acting. The conversion, including a rod whose cross-section changes along its length, is worked through in the article on how pressure loads a rod with a varying cross-section. And when a reading contradicts the obvious state of the circuit, suspect the measurement point or a valve state before the pump — the same lesson as in the case of a pump showing zero pressure after a shop move.
Three causes of a constant pressure difference #
Flow loss. Loss through lines, bends and fittings follows the flow, not the load: in turbulent flow it grows roughly with the square of the velocity, in laminar flow linearly. At a fixed pump displacement and speed the flow is the same at both loads, so the loss repeats identically — which reproduces the reported pattern exactly. Undersized lines push velocity up and loss with it; velocity high enough to lose pressure usually makes the circuit audible too, and the checks in a hydraulic system that hums under load at full speed cover that side of the fault.
Static head. A standing oil column adds pressure in proportion to height: with a typical mineral oil near 870 kg/m3, every 10 m between the two gauge heights contributes about 0.85 bar. Inside one machine frame that is a fraction of a metre and a fraction of a bar; on a tall plunger hoist it is a real correction. Take the density from your oil datasheet, not from this example.
Measurement and circuit state. Readings taken minutes apart, a check valve isolating one gauge from the other, or pressure trapped in a leg all look like a constant offset. If the offset persists with no oil moving anywhere, it cannot be flow loss; it is one of these.
Fitting accounting. The share of a segment's loss that belongs to a fitting is the measured difference minus the frictional loss of the straight piping over the same length. That makes the straight-pipe loss the first number to compute — and the same bookkeeping, straight runs first and fittings as the remainder, is laid out step by step in this guide to calculating friction and fitting losses.
Line loss in 2 m of 20 mm line at 40 L/min #
This is a calculated example for the inputs below, not a measured result. The report gives no flow or line size, so these are typical values for a small hoist power unit; substitute your own before using the result.
- Flow: 40 L/min at hoisting speed (example input).
- Line: 20 mm internal bore, 2 m between the gauge points (example input).
- Oil: ISO VG 46 grade at 40 °C, so kinematic viscosity about 46 cSt by the grade definition; density 870 kg/m3, typical for mineral oil — take both from the oil datasheet.
The rule, in words: velocity equals flow divided by bore area. Reynolds number equals velocity times bore divided by kinematic viscosity; below about 2300 the flow is laminar, and the straight-pipe loss is 32 times dynamic viscosity times length times velocity, divided by bore squared, where dynamic viscosity is kinematic viscosity times density.
The arithmetic:
- Bore area = pi/4 × (0.02 m)^2 = 3.14e-4 m2. Velocity = 6.67e-4 m3/s ÷ 3.14e-4 m2 = 2.1 m/s.
- Reynolds number = 2.1 m/s × 0.02 m ÷ 4.6e-5 m2/s ≈ 920 — laminar.
- Dynamic viscosity = 4.6e-5 m2/s × 870 kg/m3 = 0.040 Pa·s.
- Straight-pipe loss = 32 × 0.040 Pa·s × 2.0 m × 2.1 m/s ÷ (0.02 m)^2 ≈ 13,500 Pa, which is 0.14 bar.
So a healthy line of this bore and length loses about a tenth of a bar at that flow, while the reported offset is 25 bar — the same loss would need roughly 370 m of the line. Between gauge points a metre apart, the pipe cannot be the loss. If the offset still appears there with oil flowing and both gauges read simultaneously, it sits in a fitting, a valve or the measurement, and the segment check below finds which.
Match the pattern to the cause #
| What you measure | What it points to | Confirming check |
|---|---|---|
| The same offset at both loads, only while oil flows | Flow loss in a line, fitting or valve | Measure both sides of one segment at the same flow and compare with the straight-pipe loss for that segment |
| The offset changes when a gauge is moved up or down | Static head | Convert the height difference with the oil density and correct the reading |
| The offset persists with no oil moving | Measurement error, trapped pressure or an isolating check valve | Zero-check the gauges against one source and trace every closed path between the two ports |
| The offset appears in one travel direction only | A directional restriction or a valve passing in that state | Repeat the segment measurement in both directions at the same flow |
| The relief or safety valve is suspected | It can only matter if it passes flow in that state | Look for flow, or a warming return line, before touching any setting |
Find the segment that loses the pressure #
- Name the two ports on the schematic and list every component between them.
- Repeat the original readings simultaneously — same direction, same load, same flow state, same oil temperature — and write the state next to the numbers.
- Split the path between the gauges into short segments and measure both sides of each during the same flow condition. The segment where the pressure steps down is the one to investigate; move a gauge rather than trusting a port from memory.
- In the suspect segment, subtract the straight-pipe loss computed for its length, bore and flow. The remainder belongs to the fittings and valves.
- If the segment contains the relief or safety valve, establish by the machine's documented method whether oil actually passes through it in the measured state — flow at the return, or the return line warming under flow. Never adjust the setting as a trial fix.
One safety boundary around all of this: a hoist holds a suspended load on the same circuit that carries the gauges. If the ram drifts or behaves unpredictably, stop and use the machine's approved load-control procedure instead of trusting any reading. ISO 4413, the general safety standard for hydraulic fluid power systems, expects system pressure to stay within the design limits and the circuit to be safe to set and service, so treat the relief valve as that protection — diagnose around it, never through it.
The decision for each case #
- Offset identical at both loads, present only while oil flows: it is flow loss. Find the segment, then resize the line, replace the crushed fitting or clean the restriction. The mechanical checks you already did stand; nothing points back at the sheaves.
- Offset that follows gauge height: it is static head. Correct the readings for it — there is no fault in the machine.
- Offset at standstill: it is measurement, trapped pressure or isolation. Fix the gauge points or the trapped leg, not the components.
- Relief valve proven to pass flow outside a relief event: service or replace it per the machine's documents. Until that flow is proven, a constant offset never convicts the valve.
Questions asked
Does mechanical friction in a hoist ever stay constant as the load changes?
Sliding and seal drag do include parts that do not scale with load, such as packing break-out, so friction is never perfectly proportional. But a measured difference that stays identical while the load changes by dozens of bar matches a flow-dependent loss or a head offset far better than packing drag, and packing drag is confirmed at the gland, not from two gauges.
Can a faulty safety valve produce a constant pressure difference?
Only if oil actually passes through it during the measured condition. A passing relief valve consumes flow, so its effect changes with flow and it does not create a load-independent offset on its own. Prove flow in the relief return line first; where there is none in that state, the valve is not the cause and must not be adjusted or swapped as a trial.
How much does gauge height matter on a plunger hoist?
Head pressure equals the oil density times gravity times the height difference. With a typical mineral oil near 870 kg/m3, every 10 m between two gauge points adds about 0.85 bar. That is a real correction on a tall plunger hoist and negligible inside one machine frame. Take the density from your oil datasheet rather than reusing the example value.
What line velocity keeps hydraulic pressure loss small?
As a rule of thumb, not a rule: keep suction lines below about 1.2 m/s and working pressure lines in the 3 to 6 m/s band, because loss grows steeply beyond that and the circuit usually turns noisy too. Size the bore from the pump flow, then verify the choice with a loss calculation rather than trusting the velocity figure alone.