Short answer
With the indicator base rigid on the machine casting, 0.001–0.002 in of movement at the screw end is real endplay in the thrust support path, and a preloaded support should show none. The reading locates the play in that path but does not name the failed part, so check fasteners, retention and housing seating before ordering bearings.
On this page
- What the ball-in-the-center-hole test measures
- Why the reading does not convict the bearings
- Free play or elastic deflection
- Why pushing the table just spins the screw
- Working the numbers: 0.0015 in of endplay on a 0.2 in/rev screw
- What the endplay test cannot tell you
- The order of work before you order bearings
- Questions asked
You read the test correctly. With the indicator base rigid on the machine casting and the probe on a ball seated in the screw's center hole, 0.001–0.002 in of movement as thrust reverses is real endplay, and a preloaded thrust support should show none of it. What the reading does not do is convict the bearings: the same number shows up when the retention stack is loose, when the housing shifts on its mounting, or when the block bolts have relaxed. Work the cheap interfaces first, because support play of this size can account for most of a 0.002 in backlash report, which makes the support the first repair and the ball nut, and any compensation setting, a later question.
What the ball-in-the-center-hole test measures #
The end face of a used screw is a poor datum: it carries the center drill and years of handling, and you cannot trust it to be square. A single ball dropped into the center-drilled hole gives the indicator a target that sits on the screw axis regardless of the face's condition, and a dab of grease holds it there until the probe takes over. That is the ball's whole purpose — a concentric contact point, not a load-bearing part of the machine.
Two conditions make the reading valid. The indicator base must sit on the machine casting, not on way covers, the motor mount, or anything that can move with the screw. And the probe must meet the ball on the screw axis, square to it, so the probe does not nudge the ball sideways and manufacture movement that is not there.
Then, with the axis at rest, load the screw axially in both directions by hand and watch the needle at reversal. The total travel is the free axial play of the screw.
| Indicator on | Referenced to | Movement tells you |
|---|---|---|
| Ball in the screw's center hole | machine casting | free axial play somewhere in the thrust support path |
| Bearing housing | machine casting | clearance under the housing or housing-to-casting movement |
| Nut or nut bracket | table or screw | a loose or compliant nut mounting |
| Table | fixed machine member | total lost motion between screw rotation and table position |
Each placement answers a different question, and only the first one is the endplay test. The others are how you keep that first reading from naming the wrong part.
Why the reading does not convict the bearings #
Your indicator sits at the end of a chain: screw shoulder and locknut, inner-ring retention, the rolling elements, outer-ring retention, the housing bore, and the bolts that hold the block to the casting. Free clearance at any one of those interfaces puts the same travel on the needle. The reading locates play in the path; it does not tell you which element carries it.
Work the chain cheapest first, with the confirming check for each:
- Block bolts. Re-torque to spec while watching the indicator; bolt preload variation with friction and seating is why a fastener that feels tight can be holding a fraction of its assembly clamp.
- Retention parts. Inspect the locknut, the spacer or shim stack, and the end cap for a backed-off adjustment, a missing spacer, or a collar that has crept.
- Housing seating. Confirm with a second indicator on the housing, referenced to the casting. If the housing moves with the screw, the play is at the mounting face. If the housing holds still while the screw moves, the play is inside the support stack, in the retention or the bearings themselves.
A gravelly sound from the support is a reason to open the stack, not a measurement of anything; and after years of sitting idle, the lubricant deserves inspection whatever the numbers say.
One more point decides the replacement part. On a preloaded angular-contact pair, preload is a locked axial displacement of one ring relative to the other, set by the paired geometry or by the spacer stack. That is why the replacement must be the manufacturer's specified bearing and preload value: a generic angular-contact bearing with the same bore and outside diameter is not a drop-in for a pair whose preload lives in its geometry.
Free play or elastic deflection #
Clearance announces itself as a snap: the needle jumps from one limit to the other the instant thrust reverses, and pushing harder does not make the jump bigger. Elastic deflection behaves the opposite way — movement grows smoothly in proportion to force and springs back when the load comes off. One is wear or looseness; the other is stiffness. The pass condition at the screw end is zero free play. If movement only appears under load and scales with it, treat it as deflection and judge its size against the support's rated axial stiffness for that exact part, not by feel.
Why pushing the table just spins the screw #
A ball screw drives efficiently in both directions, so axial force at the nut winds the screw. That is what you saw: the screw rotated before the table moved visibly, and from that moment the test was mixing rotation with translation. No clean clearance number can come out of it. A push test is only usable when screw rotation is positively restrained, without counting on a motor brake or holding torque you have not verified and without marring the screw. The end-face indicator test needs none of that, because it loads the screw axially at the end and never asks the table to move.
Working the numbers: 0.0015 in of endplay on a 0.2 in/rev screw #
Inputs:
- Indicator travel at the screw end: 0.0015 in, the midpoint of the 0.001–0.002 in range measured on this machine.
- Screw lead: 0.200 in per revolution, the machine's ground screw.
- Reported table reversal error: 0.002 in, the number that started the investigation.
Rule in words: free screw travel adds to table reversal error one for one, because the screw floats that distance before thrust reaches the nut, and it swallows screw rotation equal to the endplay divided by the lead.
Arithmetic:
- Rotation swallowed: 0.0015 in ÷ 0.200 in/rev = 0.0075 rev, and 0.0075 rev × 360°/rev = 2.7° of rotation that moves the table nothing at reversal.
- Share of the report: 0.0015 in ÷ 0.002 in = 0.75, so 75% of the reported backlash sits in the support path.
- Residual: 0.002 in − 0.0015 in = 0.0005 in left for the nut, its mounting, and everything else in the chain.
This split is a calculated example for these inputs, not a measured allocation: the measured range was 0.001–0.002 in, so the residual elsewhere lies between 0 and 0.001 in.
Decision: three quarters of the reported reversal measured as screw float makes the support the first repair, ahead of the nut and ahead of any controller setting. After the rebuild, the end-face test must read zero free play — a remaining snap means the retention or preload stack is still not set — and the leftover at the table then decides whether the nut is next.
What the endplay test cannot tell you #
It is one number at one end. Wear distributed along the travel never appears in it; that wear shows up as reversal error that changes with table position, measured at the table. A screw that looks pristine can still be worn, and the nut's balls and tracks are internal, beyond any visual check. The test also does not measure total backlash, because the chain from commanded rotation to table position includes the coupling, the support, the nut and the mounting. Compensation can only patch an offset that is fixed everywhere; it cannot clamp a moving support, and no gain change removes clearance. For everything that shows up at the table, the sequence in diagnosing ball screw backlash, noise and vibration first takes over once the support is tight.
The order of work before you order bearings #
- Lock out the machine and block the table so the axis cannot jog or roll while your hands are at the screw end.
- Repeat the endplay test with the base on the casting, the ball greased into the center hole, and the probe on the screw axis.
- Re-torque the block bolts with the indicator live, and inspect the locknut, spacers and end cap for anything backed off, missing, or crept.
- Put a second indicator on the housing and settle the mounting-versus-internal question before opening anything.
- Open the stack only when the housing is proven still: check the lubricant, and turn the support by hand for roughness.
- Replace with the manufacturer's specified pair and preload value, then follow the rebuild sequence in fixing ballscrew thrust bearing axial play and preload and demand zero free play at the end face before running any table measurement.
Endplay first, backlash second. Until the screw cannot float, every other number you collect at that axis is measuring a moving reference.
Questions asked
How much endplay is a ball screw support allowed?
None, as free play. Preload exists to remove free axial movement, so any needle snap at reversal is clearance to eliminate, however small. Movement that grows smoothly in proportion to force is elastic deflection, not wear, and even that has a limit worth knowing: the support's rated axial stiffness for the exact part, taken from the manufacturer's data rather than judged by feel.
Why did the screw turn when I pushed the table?
Because a ball screw backdrives: axial force at the nut winds the screw instead of shifting the table, so your push was converting into rotation before any clearance could show as travel. The test therefore mixed two motions and proved nothing. Either restrain the screw's rotation positively, never by trusting an unverified motor brake, or skip the push test, since the indicator on the center-hole ball loads the screw axially and answers the endplay question directly.
Can I judge the screw or the nut by eye?
Not reliably. A screw can look pristine and still be worn over its length, and the balls and tracks inside the nut cannot be inspected visually at all. Distributed wear never shows in the endplay reading at the support; it appears as reversal error that changes with table position. Measure the table against a fixed machine member at several points along travel once the support reads zero free play.
Will backlash compensation or retuning hide this?
Compensation adds a fixed correction to commanded moves, so it can only mask an offset that repeats identically at every position and load. It cannot clamp a loose housing or restore support stiffness, and raising servo gains cannot remove mechanical clearance; the loop simply works harder across the gap. Get the support to zero free play first, and whatever repeatable residual remains at the table after that is the part compensation is meant to address.
Is the grease in the center hole part of the measurement?
No, it is a convenience. A dab of grease holds the ball in the center-drilled hole while you bring the indicator into contact, so one person can make the setup. The measurement depends on the ball giving the probe a target concentric with the screw axis and on the probe meeting it squarely; side contact can nudge the ball and register movement that is not screw movement.