Comparison
Brushless AC Servo Position Control and Holding Torque for a Lathe
Short answer
A brushless AC servo matches brushed DC accuracy on a lathe axis when the drive commutates sinusoidally, runs in torque mode with a motor-mounted encoder, and sits behind a reduction. It holds by active current through the position loop within the continuous stall rating, and a brake covers power-off hold.

On this page
- Are brushless AC servo motors accurate enough for a CNC lathe retrofit?
- Which drive should I pick: brushed DC, trapezoidal BLDC, or sinusoidal AC?
- How much torque ripple reaches the cut at the lowest feed rate?
- How do I know the feedback resolves the target at the tool?
- Can a brushless AC servo hold position against an applied force?
- How much current does a dwell under cutting load draw?
- What holds the axis when control power drops?
- What should I check on the machine before cutting metal?
- Questions asked
The weak low-speed reputation of brushless AC servo motors belongs to one commutation style, not to the motor class. Run a brushless AC servo from a sinusoidal drive, close the loop in torque mode on an encoder mounted to the motor, and keep a reduction between the motor and the screw, and the axis follows and holds as accurately as a brushed DC servo of comparable size. The deciding quantity is torque ripple at the lowest feed measured against what the axis must actually do; feedback resolution almost never turns out to be the limit. The comparison below puts the three drive options against each other for a lathe retrofit, works the ripple, resolution, and holding-current arithmetic on one example axis, and states the decision for each case.
Are brushless AC servo motors accurate enough for a CNC lathe retrofit? #
Yes: with sinusoidal commutation, torque-mode control, and a motor-mounted encoder, a brushless AC servo follows and holds a lathe axis as accurately as a brushed DC servo at a 0.001 in target.
The weak low-speed reputation attaches to one commutation method, trapezoidal or six-step drive of a brushless DC motor, not to the brushless class as a whole. Retrofit experience with torque-mode current amplifiers and encoders on the motor reports sinusoidal AC servos as readily comparable to brushed DC, with lower rotor inertia as a bonus. What decides accuracy on this kind of axis is the ripple a drive injects at crawl speeds, measured against the friction and cutting loads the axis actually sees, plus the mechanics between the encoder and the tool. Feedback resolution, the quantity people check first, is rarely the limit.
Which drive should I pick: brushed DC, trapezoidal BLDC, or sinusoidal AC? #
Pick the sinusoidal AC servo drive: it produces torque at least as smooth as brushed DC with lower rotor inertia, while a trapezoidal brushless drive switches phase current in steps that show up as cogging at crawl feeds.
The three options a retrofit actually has compare like this:
| Drive type | Low-speed behavior | What limits accuracy | Verdict for the retrofit |
|---|---|---|---|
| Brushed DC with a torque-mode amplifier | Smooth; the benchmark the others are judged against | Encoder resolution, loop gains, mechanical backlash | Accurate, but an older technology to maintain |
| Trapezoidal (six-step) brushless DC | Visible cogging at crawl feeds; one published manufacturer example puts the ripple near 14% of rated torque | Ripple measured against friction; usable only behind a reduction | Not recommended as the primary drive |
| Brushless AC with sinusoidal commutation | Equal to or smoother than brushed DC, with lower rotor inertia | Encoder resolution, loop gains, mechanical backlash | Recommended |
Brushed DC remains a valid benchmark, and a matched DC amplifier already on the shelf will hold this kind of target, but new commercial machine designs have moved overwhelmingly to brushless AC, so brushed DC means maintaining a technology the market has left behind. A trapezoidal drive is usable only behind a reduction stage, and its ripple leaves a mark in the surface finish at crawl feeds. The motor-class trade from the drive side is examined further in a guide to selecting brushed versus brushless servo motors for CNC routers.
How much torque ripple reaches the cut at the lowest feed rate? #
For a worked example at 10 mm/min feed, a 5 mm lead, a 3:1 reduction, and an eight-pole motor, six-step commutation ripple lands at 2.4 Hz with an amplitude of about 0.28 N·m, roughly 14% of that motor's 2 N·m continuous torque.
These inputs are illustrative for one example axis; on your machine, take the ripple figure and the torque rating from the drive and motor datasheets, and the method below stays the same.
The arithmetic: 10 mm/min ÷ 5 mm per revolution = 2 rev/min at the screw; times the 3:1 reduction = 6 rev/min at the motor, or 0.1 rev/s. Four pole pairs put the electrical frequency at 0.4 Hz, and a six-step drive produces a ripple component six times per electrical cycle, so the disturbance reaches the screw at 2.4 Hz. Amplitude: 0.14 × 2 N·m = 0.28 N·m at the motor shaft.
At rapid speeds, rotor inertia filters that ripple out. At crawl feeds, the ripple period is long enough that the velocity loop chases it, and it appears as feed modulation and waviness in the surface. A sinusoidal drive shapes the phase currents to the rotor angle and removes the switching steps at the source; the residual ripple depends on the motor's winding and pole design, and manufacturers do not publish it as a universal number. A reduction moves the ripple frequency up in proportion to the ratio, and while motor inertia dominates the reflected load, the carriage's speed error from that ripple falls roughly with the square of the ratio, which is the practical reason cogging is rarely apparent behind any real reduction stage.
Decision: if you intend to cut at crawl feeds, the sinusoidal drive is the deciding choice. A six-step drive becomes usable only behind a reduction, and its fingerprint will still show in the finish. Choosing the ratio follows the same arithmetic as sizing servo reduction for belt-driven machine axes.
How do I know the feedback resolves the target at the tool? #
Compute counts per screw revolution and divide the lead by them: on the worked-example axis, a 2500-line encoder with quadrature gives 30,000 counts per screw revolution, so one count is about 0.0000066 in at the tool, roughly 150 times finer than the 0.001 in target.
Quadrature delivers 4 counts per line: 4 × 2500 = 10,000 counts per motor revolution; times the 3:1 reduction, 30,000 counts per screw revolution; 5 mm ÷ 30,000 = 0.000167 mm, about 0.0000066 in. This is a calculated example for these inputs.
A feedback resolution near one tenth of the tolerance is a common practice target, an engineering convention rather than a requirement from any standard. The formula counts only the encoder: backlash and compliance sit outside it, so verify at the tool with a dial indicator. With the encoder on the motor, backlash sits between the measurement and the cut, and resolution the loop can see is not position the tool holds.
Decision: on any plausible encoder and reduction, resolution is not what limits this axis; the mechanics are.
Can a brushless AC servo hold position against an applied force? #
Yes, actively: the motor has no useful passive detent, so the drive holds by commanded current through the position loop, and the hold resists the force for as long as the current stays within the motor's continuous stall rating.
Three limits govern the hold:
- Stiffness: with proportional action only, the axis deflects under an applied force by that force divided by the loop's effective stiffness. An integrator in the velocity or position loop drives the steady-state error back to zero and keeps it there until the current limit saturates.
- Thermal: at standstill, the hold current is direct current in whichever windings the rotor angle selects, so copper loss concentrates in one or two phases. Size the hold against the continuous stall torque on the motor datasheet, never the peak figure.
- Mechanics: a reduction multiplies the torque available at the screw by the ratio and divides the load torque reflected to the motor by the same factor. Backlash between encoder and tool defeats that stiffness unless the stage is low-backlash or preloaded.
Decision: the hold is real and stiff; its ceiling is the continuous stall rating, and the integrator is what makes the error disappear under a steady cutting force.
How much current does a dwell under cutting load draw? #
On the worked-example axis, an 800 N axial cutting force holds at about 0.29 N·m and 0.58 A at the motor, roughly 15% of the continuous stall current, which is what keeps an indefinite dwell inside the thermal limit.
The arithmetic, as a calculated example for these inputs: axial force on a screw produces 800 N × 0.005 m ÷ 6.283 = 0.64 N·m at the screw; add 0.15 N·m of slide friction for 0.79 N·m; reflect through the reduction at 90% efficiency, 0.79 ÷ 3 ÷ 0.9 ≈ 0.29 N·m at the motor; divide by the torque constant, 0.29 ÷ 0.5 N·m/A ≈ 0.58 A. The example motor's continuous stall current works out to 4 A.
Decision: a dwell under this load sits far below the continuous stall limit, so the hold is thermally safe indefinitely on this example. Run your own inputs the same way, because the datasheet values decide; the method is identical to calculating servo motor current from required torque.
What holds the axis when control power drops? #
Nothing: a servo holds only while the drive is powered and commanding current, so any axis that can fall, sag, or creep under gravity or stored energy when power is lost needs a spring-applied holding brake sized for the static load.
A spring-applied brake engages when power is removed and releases when its coil is energized, which is the fail-safe direction for an axis under gravity or stored energy. A horizontal lathe slide sees less consequence from a power drop, but a tilted bed, a vertical axis, or a quill carrying spring energy changes the case. Treat power-loss motion as a hazard source in the machine's risk assessment, which is what ISO 12100, the machinery risk-assessment standard, requires: hazards from the loss of energy sources are identified and reduced like any other. The brake parks the axis; it does not position it, and what a servo motor holding brake does and does not do covers that distinction.
What should I check on the machine before cutting metal? #
Run four checks at the lowest feed you will actually cut: velocity ripple on the drive trace, holding current against the continuous stall rating, following error under a known applied force, and bidirectional repeatability at the tool against the accuracy target.
- Velocity ripple at the lowest planned feed, read from the drive's velocity feedback trace: visible modulation means ripple or loop gain is still too high.
- Holding current at standstill, read from the drive's current monitor against the continuous stall rating on the datasheet.
- Following error under a known force: press the carriage with a force gauge while watching the following-error display and a dial indicator at the tool; with the integrator active, the error must return to zero.
- Bidirectional repeatability at the tool: repeated approaches from both directions, compared against the accuracy target.
If the following error persists while the integrator is active, the current limit is saturated or backlash sits between the encoder and the tool. If velocity ripple survives after the gains are backed off, the cause is commutation, not tuning. The decision for the retrofit as a whole: buy the sinusoidal drive, run it in torque mode with the encoder on the motor, keep a reduction on the screw, hold within the continuous stall rating, and brake any axis that can move on power loss.
Questions asked
Can I drive a brushless AC servo motor with my existing brushed DC servo amplifier?
No. A brushed DC amplifier commutates mechanically through the brushes and applies one armature voltage. A brushless AC motor needs a drive that reads rotor angle from the encoder and shapes currents in the three phases in step with that angle. The two amplifier types are not interchangeable, and no adapter converts one into the other.
Where should the encoder sit: on the motor or on the ball screw?
Motor-mounted is the standard arrangement, and it is what the worked example assumes: it closes the commutation and velocity loops where the drive needs them. A linear scale on the slide measures past backlash and compliance, so it improves tool-side accuracy when the mechanics cannot be preloaded tight, but it changes neither the motor-side hold nor the ripple behavior at the motor.
How do I tell a commutation fault from a loop-tuning fault?
Jog the axis slowly and watch where the disturbance sits. Ripple that repeats at the same rotor angle regardless of axis position or load points to commutation or cogging. An oscillation whose frequency and amplitude shift when you change loop gains is a tuning fault. Heating while the axis sits still points to excessive stall current rather than to either.
What should I have ready before contacting the drive manufacturer about persistent ripple?
Have the motor datasheet with its torque constant, pole count, and continuous stall rating, the encoder specification, the drive model, and a captured velocity or current trace at the lowest feed you need to cut. The ripple frequency in that trace lets support tell quickly whether the disturbance is commutation, mechanics, or loop gain.