Short answer

A servo motor holding brake is a spring-applied, power-off mechanical clamp that holds a stationary shaft when torque or power is gone. Controlled deceleration stays the drive's job unless the brake datasheet explicitly permits dynamic duty. Size it against the reflected gravity torque with margin, and sequence release only after torque is established.

On this page
  1. How the brake is built and what engages it
  2. Holding versus dynamic braking
  3. Where the requirement comes from: gravity torque at the motor shaft
  4. What IEC 61800-5-2 gives you — and what it does not
  5. Wiring and sequencing: no unsupported interval
  6. The decision
  7. Questions asked

The short answer: a servo motor holding brake is a mechanical clamp, not a deceleration device. It is a spring-applied, power-off brake built into the rear of the motor that holds a stationary shaft against gravity or inertia when servo torque or electrical power is gone. Stopping the axis while it moves is the servo drive's job, done with commanded opposing motor torque — unless the brake's own datasheet explicitly permits dynamic duty for that exact motor and brake option, it does not.

How the brake is built and what engages it #

Nearly every integrated servo holding brake is a spring-applied, power-off design: a friction disc clamped by springs, released when DC voltage is applied to the field coil. Power to the coil means free shaft; power lost means the springs clamp the disc and the shaft holds. That is the design's whole purpose — holding or parking a stationary servo motor, as brake technical data from motor makers such as Kollmorgen states plainly, adding that the brake is not intended for dynamic braking.

The consequence of the power-off principle is that motor power and brake coil power are independent circuits. Cutting drive power does not by itself put the axis in a defined state; the brake takes a finite, documented time to develop full holding torque, and during that interval a gravity-loaded mechanism can move.

Holding versus dynamic braking #

Dynamic braking means producing retarding torque while the shaft rotates, converting the load's mechanical energy into heat — in the drive's DC link, in a braking resistor, or in the brake friction surface. A spring-applied static brake that touches a rotating shaft converts that same energy into friction heat on a small disc designed for clamping at standstill. Repeated engagement at speed glazes and wears the friction face and overheats the coil housing.

Decide each stop type separately:

Operating requirement Primary means What to verify
Decelerate during a normal cycle Drive and motor torque Braking-energy handling and deceleration limits
Hold position with drive energized Closed-loop servo torque Continuous torque and thermal load
Hold position without motor torque Mechanical holding brake Static holding torque against reflected load
Arrest motion after a fault or e-stop Designed stop-and-hold system Documented brake duty and safety requirements

If your cycle needs every-stop dynamic duty from the brake, you are reading the wrong datasheet: select either a brake with a documented dynamic rating or a drive-side solution, not a holding brake pushed beyond its written intent.

Where the requirement comes from: gravity torque at the motor shaft #

The brake restrains the motor shaft. The load on it is whatever gravity or stored energy reflects back through the transmission at the worst position — not the nominal mid-stroke position, and not proportional to motor size. On a coupled mechanism such as a Delta or SCARA arm, that worst case can sit away from the working centroid, so calculate the gravity-induced torque across the workspace using real geometry, ratios, masses and any process force that survives a production stop.

Worked example: a vertical lift on a ball screw #

Inputs: a 10 kg payload plus 5 kg carriage, a ball screw of 5 mm lead, transmission efficiency 0.9, and a gearbox of 1:1 (none).

  • Gravity force: F = m·g = 15 kg × 9.81 m/s² = 147.15 N
  • Torque to hold the load: T = F·L / (2π·η) = 147.15 N × 0.005 m / (2π × 0.9) = 0.736 / 5.655 ≈ 0.130 N·m
  • Rule-of-thumb margin (brake static torque about 50 percent above requirement, per common brake-selection practice): 0.130 × 1.5 ≈ 0.195 N·m
  • Decision: choose the brake option whose datasheet static holding torque is at least 0.20 N·m after temperature and engagement deratings, and verify the gearbox (if later added at 3:1) divides the requirement by 3, giving 0.043 N·m at the motor.

This is a calculated example for these inputs, not a measured result. Two things move it and by how much: efficiency (dropping from 0.9 to 0.7 raises the requirement to about 0.167 N·m) and gearbox ratio (dividing it directly). Note also that efficiency works against you only when the load drives the screw — backdriving — which is exactly the holding case; use the backdriving efficiency from the screw datasheet when it differs from 0.9.

The brake holds the motor shaft, so it retains the load only through an intact transmission. If a coupling, keyway or linkage downstream can fail, the brake does not retain the load after that failure; the machine's risk assessment must decide whether that state is acceptable. For the joint between a motor or gearbox shaft and the driven shaft, see the flexible-coupling selection concerns in how to calculate servo motor current from required torque when you also need the acceleration current that shares the shaft path — sized separately from the brake.

What IEC 61800-5-2 gives you — and what it does not #

IEC 61800-5-2 defines safe functions for adjustable-speed drives, the best known being Safe Torque Off (STO): the drive is prevented from producing torque-generating power, achieved without opening the power contacts. STO guarantees the motor will not be driven — it does not hold a vertical load. A gravity axis with STO alone can fall, because nothing mechanical restrains the shaft once the drive stops producing torque.

So the pairing is: STO (or the emergency-stop concept of your machine's risk assessment) removes torque-producing energy; the holding brake provides the mechanical restraint for the load. For a horizontal axis whose loss-of-torque state is a load sitting still on a slide, the risk assessment may accept no brake at all; for a gravity axis, a brake or an independent mechanical counterbalance is the answer, sized per the calculation above.

One safety note: validate the complete stop-and-hold chain — torque removal, brake engagement, sag during the transition interval — against the machine's risk assessment and the applicable standard; no datasheet value or article substitutes for that validation.

Wiring and sequencing: no unsupported interval #

The control sequence must transfer load support between servo and brake without an interval where neither holds. The usual sequence, using the timing values from the selected motor and drive documentation (not arbitrary delays):

  1. Establish controlled motor torque with the axis at the target position.
  2. Command brake application and keep motor torque alive for the documented application interval; the brake takes over the load.
  3. Remove torque or power; the shaft is now held mechanically.
  4. On restart, command torque first, then release the brake, and allow the documented release interval before moving.

A release command is not proof the brake has physically opened, and an application command is not proof full holding torque has developed. With the mechanism safely supported during commissioning, verify coil voltage and polarity at the brake connector against the motor documentation's specification, confirm no gravity drop at release, and confirm position stability through the transfer to mechanical holding. Brake-coil supply and switching interface requirements — including suppression — come from the motor and drive manuals; the drive's brake-control output must be compatible with the coil's voltage and current.

The decision #

  • Horizontal axis, safe loss-of-torque state: no brake needed; buy the motor without the brake option.
  • Gravity axis, vertical lift, or axis with stored energy: brake option required, sized so datasheet static torque ≥ 1.5× the reflected worst-case load torque, and retained only where the transmission cannot fail underneath it.
  • Every-cycle stopping or deceleration: the drive's job, always. Use the holding brake only at standstill, unless the brake datasheet explicitly states a permitted dynamic or emergency-stop duty with engagement speed and cycle limits for that exact part.
  • Emergency stop: STO per IEC 61800-5-2 removes torque; the brake holds the load; the combination, not either alone, is the validated design.

Questions asked

Can I use the holding brake to stop a moving axis in an emergency?

Only if the brake's own documentation states a permitted emergency-stop or dynamic duty with engagement speed and cycle limits for that exact motor and brake option. A holding-only brake glazing or wearing from repeated engagement at speed is a real failure mode, and a single permitted e-stop use does not make it suitable for every-cycle stopping. Route emergency stopping through the drive unless the datasheet says otherwise.

Does removing motor power apply the holding brake automatically?

On the standard spring-applied, electrically released design, yes: coil power off equals brake applied. But motor power and brake coil power are separate circuits, and removing one does not establish the required state of the other. A supply interruption removes drive torque before the spring fully develops holding torque, so a gravity axis can sag through that interval unless the design accounts for it.

How much margin should the brake have over the calculated holding torque?

A common industry practice is a brake static torque roughly 50 percent above the load requirement; treat it as a rule of thumb, not a rating. The final margin comes from your machine's risk assessment and the datasheet deratings: temperature, engagement history, and any gearbox efficiency allowance. In the worked example, the 0.087 newton-metre requirement against a 0.17 newton-metre brake gives about 2:1.

Why does my vertical axis still drift a little with the brake applied?

A few possibilities in order of cheapness: the brake engages while the axis is still moving and drags to a stop (check the sequence timing); the holding torque is below the reflected load after derating (recalculate); or the drift you see is mechanical deflection or backlash downstream of the motor shaft, which a motor brake cannot restrain. The motor encoder showing a stationary shaft does not prove the load did not move.

Do I need a brake on a horizontal axis at all?

Usually no. If losing torque leaves the load in a safe, stable state — a horizontal slide that simply stops, no gravity fall, no stored spring or counterweight energy — the risk assessment may accept a brake-less motor, and the standard spring-applied brake is not doing useful work. Gravity axes, vertical lifts, and axes with stored energy are the ones where the holding brake is the answer.

Keep reading

  • Troubleshooting

    Servo Motor Rear Noise: Brake or Bearing, Not Gears

    Rear servo noise under the resolver cover is the spring-applied 24 V brake or the rear bearing, and the motor holds bearings, not gears. Verify brake release under electrical load first: brake drag shows up as current rise, heat and noise tied to release events, while bearing noise tracks shaft speed and survives a brake proven healthy.

    Servo and stepper motion

  • Troubleshooting

    Servo Position Counts Up While the Motor Is Stationary

    Counts that rise while the motor shaft is held still are false feedback counts, not motion. Compare the controller's tell-position reading against the drive's rotor-position display: a drive value steady within 1 count while the controller climbs condemns the simulated-encoder path. Isolate the encoder output, cable, breakout and counting input by substitution, one part at a time, cheapest check first.

    Servo and stepper motion

  • Explainer

    Servo Positioning Resolution Versus Stepper Step Angle Explained

    A 0.018° move needs 360 ÷ 0.018 = 20,000 usable feedback counts per revolution, which come from the encoder and the drive's decoding and scaling, not from the servo label. Matching 3,000 command pulses per revolution on a stepper and a servo only matches command scaling; short-time overload capacity and high-speed performance still differ.

    Servo and stepper motion