AutomateDirectUSAMotion LibraryShop the parts catalog

Troubleshooting

Diagnosing a Servo Axis That Jogs in Steps With Fluctuating Current

Servo and stepper motion Published 8 min read

Short answer

Stepping motion with a 1-2 A current swing and clean encoder feedback means torque demand is changing along the travel: check brake drag, coupling condition, gibs and screw alignment under load before substituting drives or motors. Record current and encoder error together, work the cheap checks in order, and let the uncoupled motor test separate mechanics from motor.

On this page
  1. What does a 1-2 A current swing during a steady jog mean?
  2. How do I set up the controller trace before changing parts?
  3. Which checks come first, from cheapest to most convincing?
  4. Why does the axis step once the old way when I reverse the handwheel?
  5. How much drag does a 2 A current swing represent at the screw?
  6. What result proves the mechanics, the motor or the feedback?
  7. What does a completed fix look like on the trace?
  8. Questions asked

A servo axis that walks through a jog in visible steps while its current swings 1-2 A, with encoder error staying clean, is showing you varying mechanical drag — brake, coupling, ways and gibs, or screw alignment — not a drive fault, and not something to fix by retuning. The drive is doing its job: it raises torque wherever the axis gets harder to push, and current is where you see that happen. Record current and encoder error together, then work the mechanical checks in order of cost and confirm each one. In the case that matches this pattern, screw support bearings and the drive had both been swapped with no change — the checks below are what separate the causes.

What does a 1-2 A current swing during a steady jog mean? #

It means torque demand is changing along the travel, and with encoder error staying clean that points at varying mechanical drag — brake, coupling, ways and gibs, or screw alignment — not at the drive you already replaced.

Current is the drive's torque command made visible. Motor torque is current times the motor's torque constant, the figure the motor datasheet gives in N·m/A, so at a fixed jog rate current tracks load. On a healthy axis at steady speed it sits nearly flat: way friction, screw losses, and whatever gravity or the counterbalance leaves on the motor.

A swing of that size during otherwise linear travel therefore means the load itself changes as the saddle moves. Worn bearings raise friction well before they make noise; binding anywhere in the train raises the torque the drive must deliver, and the drive simply delivers it. The encoder error trace is the other half of the verdict. Encoder error is the servo's own report of how well it follows, and on this fault it stayed regular. Smooth feedback plus swinging current sends you to the mechanics; irregular or growing error would send you to the feedback chain, the encoder coupling or tuning instead. That division is the whole diagnosis.

How do I set up the controller trace before changing parts? #

Record motor current and encoder position error together, at one slow fixed jog rate, over the same stretch of travel in both directions, then repeat the identical move on the smooth axis of the same machine for a baseline.

Capture on one timebase:

  • motor current and encoder position error simultaneously
  • the same stretch of travel in both directions, plus the reversal between them
  • table position, so current peaks can be matched to specific places in the travel
  • the identical move on the smooth axis at the same rate, as your reference

Then read the shapes:

  • Peaks that repeat at the same table position every pass mark a local tight spot — ways, gibs or rail condition at that spot.
  • Peaks spaced one screw lead apart in table position repeat once per screw revolution and point at the screw itself or its support bearings.
  • An offset that flips sign when you reverse direction is gravity or counterbalance; an addition present in both directions is friction. Jog up and down at the same rate and subtract the two traces.

Which checks come first, from cheapest to most convincing? #

Run brake release, coupling condition, gib clearance, screw support alignment and the uncoupled motor, in that order; each has a confirming check, and each one you clear removes a whole family of causes before any part substitution.

  1. Brake release. A dragging brake adds torque in both directions and produces exactly this trace. Confirm the rated release voltage from the brake datasheet is actually present at the brake connector when the control commands release, and that standstill current drops when it does.
  2. Motor-to-screw coupling. Inspect for a cracked spider or disc element and for clamp screws below their datasheet torque. Confirm by checking for fretting powder at the hubs; a cracked element is replaced with a flexible shaft coupling matched to the shaft bores and the datasheet torque rating, not re-clamped harder.
  3. Ways and gibs. With clean feedback this is the prime suspect, and it is cheap to feel. Confirm in the machine's lockout state: bar or hand-crank the screw through the full travel and feel for the tight spots the trace marked, and check the gib screws for an even setting and gibs that bind at one end of travel. On lathes, cross-slide gibs typically need adjustment more often than the long-axis gibs, so do not assume the axis that still moves smoothly is set right.
  4. Screw supports and alignment. Replacement angular-contact bearings only help if they were preloaded to the bearing manufacturer's figure and mounted square to the ways. Confirm with the once-per-revolution current signature from the trace; if it is present, indicate the screw for runout and recheck preload and mount squareness.
  5. Motor and feedback, isolated. One safety note, and it belongs here: uncoupling is work inside the machine's energy sources, so put the machine in its lockout state first — in the US that is 29 CFR 1910.147, which requires isolating every energy source, locking it and verifying zero energy before you reach in — and on a vertical axis, block or crib the load before the motor comes off, because the brake no longer holds anything. Then jog the bare motor at the same slow rate. Current should sit near the motor's no-load level and stay flat. Stepping that survives uncoupled moves suspicion to the motor or feedback; failing motor bearings usually announce themselves with noise and rough running before this stage, the pattern laid out in servo bearing versus feedback failure signs.

Why does the axis step once the old way when I reverse the handwheel? #

That single step is lost motion being taken up — backlash in the coupling, worn screw support bearings, or a loose gib pair letting the saddle rack on box ways — and you measure it with a dial indicator before deciding which.

Set a magnetic base on the machine frame with the indicator tip on the saddle near the screw's line of action. Wind the handwheel one direction until the indicator moves, zero it, then reverse. The handwheel rotation you command before the indicator responds is the reversal lost motion. As a rule of thumb, a preloaded ballscrew axis should show under about 0.05 mm at the table; beyond that, trace it to its source rather than tuning around it.

Two indicators localize the source: one on the saddle, one on the motor shaft or coupling housing. Play that appears at the screw side while the motor side stands still points into the screw train; movement that shows as the saddle shifting or lifting on the ways points at loose gibs letting it rack at the direction change. For the screw-side procedure in full, follow diagnosing CNC ballscrew backlash and axis drift.

How much drag does a 2 A current swing represent at the screw? #

For the worked example below, a 2 A swing is about 2.0 kN of axial force at the nut — roughly 1.0 kN per amp on these inputs — which is the scale of a genuine way or gib tight spot, not sensor ripple.

Calculated example, not a measurement. Inputs:

  • torque constant, from the motor datasheet: Kt = 0.9 N·m/A
  • measured swing on the example axis: ΔI = 2 A (the top of the reported 1-2 A range)
  • ballscrew lead: L = 5 mm = 0.005 m
  • screw efficiency assumption: η = 0.90

Torque swing: ΔT = Kt × ΔI = 0.9 N·m/A × 2 A = 1.8 N·m.

Axial force at the nut: F = 2π × ΔT × η / L = (2π × 1.8 N·m × 0.90) / 0.005 m = 10.18 N·m / 0.005 m ≈ 2036 N ≈ 2.0 kN.

Per amp on these inputs: 2036 N / 2 A ≈ 1.0 kN/A. A load variation of 2 kN is structural — way and gib drag, not electrical noise — and it is enough to make a slow jog visibly step as the drive winds torque up and down through it. What moves the number: a motor with twice the torque constant doubles the force per amp, a 10 mm lead halves it, and a worn screw with poorer efficiency delivers less force for the same current. For the reverse direction, current from a known torque, the method is in calculating servo motor current from required torque.

What result proves the mechanics, the motor or the feedback? #

Current that flattens when the motor runs uncoupled, with the encoder trace staying regular, convicts the mechanics; stepping that survives uncoupled, or encoder error that turns irregular, moves the case to the motor and feedback chain.

The verdicts, in order:

  • Encoder error regular, current swinging through travel, uncoupled motor flat: the mechanics are the cause. Correct the gib setting, alignment or brake drag the trace marked, then re-run the identical trace.
  • Stepping or current swing that survives the uncoupled motor: motor or feedback. With the encoder coupling already inspected, weigh motor bearings and the feedback cable next, through the machine builder's test procedure.
  • Encoder error irregular or growing: feedback chain first — connector, cable, encoder coupling — before the motor.
  • Everything regular but the axis still misbehaves: only now read the gains, and do not retune to flatten a drag peak. Gains tuned over a tight spot hide the fault and pour heat into the motor.

What does a completed fix look like on the trace? #

The axis traverses both directions at the test jog rate with current near the smooth axis's baseline, encoder error flat and the reversal step gone, verified at several positions across the full travel.

Repeat the exact comparison that caught the fault: same jog rate, same stretch, same baseline axis. Re-check at several positions so one local tight spot cannot hide between test points, and again after the first thermal cycle. Keep the before and after traces; they become this machine's baseline the next time current starts to swing. If the mechanical checks all pass and the swing still exceeds the smooth axis's baseline with clean feedback, take the motor and feedback path to the builder's isolated test next — as the last step, not the first.

Questions asked

How much current fluctuation is acceptable during a steady jog?

There is no published universal limit, so use the machine's own baseline: run the smooth axis of the same machine at the same jog rate and compare. A swing several times larger than the smooth axis shows, or one that repeats at the same table positions every pass, is abnormal. On the example axis, 1-2 A against a near-flat baseline on the sister axis was enough to justify the full mechanical investigation.

What makes the axis step one extra time after a handwheel reversal?

Lost motion somewhere in the drive train: coupling backlash, worn screw support bearings, or loose gibs letting the saddle rack on box ways at the direction change. Measure it with a dial indicator on the table: as a rule of thumb, a preloaded ballscrew axis should show under about 0.05 mm of reversal lost motion, and anything beyond that deserves tracing to its source before any servo tuning is touched.

Is it worth replacing the drive or the motor first?

No. In this pattern substitution has already failed once, and a new drive tests nothing about ways, gibs, alignment, brake drag or the feedback cable. Replace parts only after the uncoupled motor jog and the trace isolate that path: current that flattens when the motor runs uncoupled clears the motor, and stepping that survives it clears the mechanics.

Do incremental encoders make this diagnosis harder?

Not for this fault. The encoder is the reference the drive corrects against, and its error trace staying regular while current swings is exactly what varying mechanical drag looks like. Incremental feedback only matters at power-up homing and reference return; it does not mask a load-induced current swing during a jog.

Keep reading

  • Troubleshooting

    Diagnosing Servo Axis Position Drift in the Drivetrain

    The drift is lost motion between the motor encoder and the load: the position loop closes at the motor shaft, so the gearbox, coupling, pulleys and belt sit outside it. Split motor-reported position from an independently measured load position at one reference with witness marks on every hub. A one-direction offset that grows for hours while the motor reads on target is index loss — slip or jumped teeth — until the marks prove otherwise.

    Servo and stepper motion

  • Selection guide

    Counting Real Axes Before Selecting a Gantry Motion Controller

    Count independent servos, not marketing axes: this machine is 13 controlled axes (1 X, 4 Y, 4 Z, 4 C), so the controller must coordinate 13. Size the payload forces first — 300 N horizontal and about 1,772 N accelerating up on Z — then use a PLC with integrated motion driving servos on one deterministic fieldbus unless robot-style kinematics or conveyor tracking saves real development time.

    Servo and stepper motion

  • Troubleshooting

    Make a Servo Jog Follow a Joystick Velocity Demand

    A velocity jog reads its speed operand only when the instruction executes, so a running jog ignores the joystick value until you re-execute it. Strobe the jog every scan with the scaled stick velocity and keep a deadband at neutral; any lag left after that is the acceleration limit, not the command path.

    Servo and stepper motion