Short answer

An absolute encoder overspeed alarm means the encoder counted rotation faster than the limit that applies while it runs on its backup battery, so the usual cause is a shaft that turned while control power was off. Find when the alarm fires, fix that condition, clear it with the drive's documented encoder reset, and re-home the axis before running parts.

On this page
  1. What the alarm condition actually says
  2. First checks, cheapest first
  3. Where in the move it fires
  4. Worked example: a power-off move on a 10 mm/rev screw with a 2:1 belt reduction
  5. Clearing the alarm the documented way
  6. When to replace parts
  7. Questions asked

An absolute encoder overspeed alarm is a speed-limit fault, not a position-accuracy fault: the encoder counted rotation faster than the limit that applied at that moment. Drive manuals state the trigger as rotation above the specified rate while the encoder is battery-powered — some families number the fault 41 and call it absolute encoder overspeed, and the alarm tables that use A.xx numbering list A.85 as encoder over-speed. In plain terms, the shaft turned while control power was off.

Answer one question first: did anything turn that shaft while the control power was off? If it did, that is the cause, and the fix is procedure, reset and re-home — a holding brake that actually holds on vertical axes, a full stop before control power comes off, then the drive's documented encoder reset (Fn011 on the drive families that use the A.xx alarm tables) and a re-home. If the alarm fires during powered moves instead, work the speed settings, then the configuration, then the feedback hardware, in that order.

What the alarm condition actually says #

A battery-backed multiturn encoder keeps its revolution counter alive from a backup battery when control power disappears. With control power on, the counter is fed from the drive and tracks the motor across its full speed range. With control power off, it counts on the battery, and that path exists to hold the turn count through a power loss, not to follow fast rotation. The drive watches it and raises the overspeed alarm when the battery-powered counting limit is exceeded.

Two speed numbers govern the same encoder, and both are printed in the documentation of the exact motor and encoder: the maximum speed with power on, and the battery-mode rotation limit with power off. The second is a fraction of the first — that separation is the reason battery-powered rotation gets its own alarm. Take each number from the document for your part; a figure from another encoder family proves nothing about yours.

This alarm is also not the multiturn counter running past the end of its revolution range. That condition shows up as a separate absolute encoder counter overflow alarm — A.46, encoder multiturn information overflow, in the tables that use that numbering — and it has its own handling.

First checks, cheapest first #

  1. Power-off movement. Ask what happened between control power off and the alarm: a hand-cranked screw, an axis that coasted or dropped after a stop, gravity pulling a vertical axis with a worn or missing holding brake, stock or a belt dragging the motor shaft. The confirming check: the alarm appears at power-up or on enable, only after such a move, and a slow single-turn rotation with power off — kept under the battery-mode limit — does not trip it.
  2. Commanded speed against the encoder's rated maximum. Pull the encoder's maximum speed from the motor documentation and read the drive's speed-limit settings, including jog and rapid. The confirming check: jog the axis in increasing speed steps and record the lowest speed that trips the alarm; a clean speed below a tripping speed points at the encoder's tracking limit, not at the mechanics.
  3. Drive-to-encoder configuration. A wrong motor code or pulses-per-rev setting makes the drive misread feedback that is otherwise healthy. The confirming check: the parameter matches the motor nameplate or the commissioning record, and the fault dates from a parameter change or a drive swap.
  4. Encoder cable and connectors. The confirming check: with the axis enabled and at rest, watch the drive's speed monitor while you flex the encoder cable and its connectors; speed readings that appear at standstill point at the wiring, not the machine.
  5. Swap test, when two identical axes or a spare drive exist. Return every cable to its original position and swap only the drives. If the overspeed moves to the other axis, the drive is the fault; if it stays with the same motor, the encoder or its cable is the suspect, and the cable is the cheaper of the two to clear first.

Where in the move it fires #

When it fires Most likely cause Confirming check
At power-up or on enable The shaft turned while control power was off The alarm repeats only after a power-off move
On the acceleration ramp Peak speed or overshoot above the encoder's rated maximum, or a configuration mismatch Compare the commanded peak with the documented maximum; verify the motor-code parameter
At constant commanded speed The command exceeds the encoder's tracking limit Jog bracket test from check 2
At standstill, no command Feedback signal fault: cable, connector, noise Flex test with the speed monitor on
First run after maintenance Disturbed connector, or a different encoder than the drive expects Re-seat connectors; recheck configuration against the nameplate

Faults that appear only when ramps steepen have the same diagnostic shape across servo axes, and why a servo faults when acceleration ramps increase works the same logic from the torque side.

Worked example: a power-off move on a 10 mm/rev screw with a 2:1 belt reduction #

Inputs — example machine values, so substitute your own:

  • Motor rated speed: 3,000 r/min, from the motor nameplate.
  • Belt drive: an 18-tooth pulley on the motor shaft and a 36-tooth pulley on the screw, a 2:1 reduction, from the mechanical arrangement.
  • Ball screw lead: 10 mm per revolution, from the screw drawing.
  • The event: with control power off, the axis was pushed 150 mm along the screw in about 2 s.

Rule in words: convert the power-off move into an average motor-shaft speed, then compare it with the battery-mode limit printed in the encoder documentation.

Arithmetic:

  • Screw revolutions: 150 mm ÷ 10 mm/rev = 15 rev.
  • Motor revolutions: 15 rev × (36 teeth ÷ 18 teeth) = 30 rev.
  • Average motor speed: 30 rev ÷ 2 s = 15 rev/s, and 15 rev/s × 60 s/min = 900 r/min.
  • Powered rapid, for contrast: 3,000 r/min × (18 ÷ 36) = 1,500 r/min at the screw, and 1,500 rev/min × 10 mm/rev = 15,000 mm/min = 250 mm/s of axis speed.

Result: an axis that runs 250 mm/s rapids under power with no alarm was pushed at 75 mm/s (150 mm ÷ 2 s) with power off, and that push turned the motor at 900 r/min on the battery. This is a calculated example for these inputs, not a measured test.

Decision: take the battery-mode rotation limit from the encoder's documentation — it is the one number this check needs. At 900 r/min average, with a hand-push that peaks higher, any limit below 900 r/min confirms the alarm as the encoder doing its job. The repair is procedural: a holding brake that actually holds on vertical axes, a full stop before control power comes off, and no hand-cranking under power-off; then reset and re-home, and replace nothing. If 900 r/min sits below the printed limit, the power-off move is not the cause, and you continue with the speed, configuration and wiring checks.

Clearing the alarm the documented way #

Correct the cause first — a reset on an axis that still turns under power off will only alarm again. Then use the drive's documented path: on the drive families whose alarm tables use the A.xx numbering, the absolute-encoder fault reset is the Fn011 setting, and the same documentation gives the outcome rule for absolute-encoder faults: if the alarm cannot be reset by setting Fn011, replace the encoder. Controller-based systems document the equivalent step as initializing the absolute encoder to clear an A.810 alarm. A plain power cycle clears a latched encoder alarm only where the manual says it does, so assume it does not until you read otherwise.

Safety and verification in one pass: re-home or re-reference the axis before trusting any stored position — overspeed on battery can skip counts — and make the test run with the machine closed and the axis clear of people and tools, through acceleration, constant speed and deceleration, confirming the alarm does not return.

When to replace parts #

Replace the encoder when the documented reset will not clear the alarm, when the swap test keeps the fault on the same motor, or when inspection finds physical damage. Replace the drive when the fault follows the drive in the swap test. Repair or replace the cable and connectors when the standstill speed monitor reacts to the flex test. None of these applies while the cause is a power-off move: that one you fix with procedure, not parts.

Questions asked

Does an absolute encoder overspeed alarm mean the encoder is bad?

Usually not. The documented trigger is rotation above the specified rate while the encoder runs on its battery, and the usual source is a shaft that turned while control power was off. Replace the encoder only when the documented reset will not clear the alarm, when a drive swap leaves the fault on the same motor, or when inspection finds damage. Check the backup battery on general principle, but this alarm is about rotation rate, not battery voltage.

What is the battery-powered speed limit on an absolute encoder?

It is the maximum shaft speed the encoder can count while running on its backup battery with control power off, and it is printed separately from the powered maximum speed in the documentation for the exact motor and encoder. It is a fraction of the powered rating. If your documentation prints only one maximum speed, that one is the powered rating; the battery-mode limit is stated separately where it exists.

Will lowering the speed settings stop the alarm?

Only when the alarm fires during powered moves above the encoder's rated maximum. Compare the commanded peak speed, including jog and rapid, with the documented maximum and set the drive's limit below it. If the process cannot live under that ceiling, the feedback is undersized for the axis and the motor and encoder choice has to change, not the tuning. If the alarm appears at power-up after the axis moved with control power off, the speed settings are irrelevant.

Is the axis position valid after the alarm is cleared?

Treat it as unverified. Overspeed while the encoder was on battery can skip counts in the multiturn position, so the stored number can be wrong even with the alarm cleared. Re-home or re-reference the axis, then run it through acceleration, constant speed and deceleration and confirm the alarm does not return.

How do I tell the drive from the encoder?

Run the swap test from check 5: exchange the drives between two identical axes and nothing else. If the overspeed moves to the other axis, the drive is at fault and you replace it. If it stays with the same motor, the encoder or its cable is the suspect, and the flex test with the drive's speed monitor at standstill clears the cable before you condemn the encoder.

Keep reading

  • Troubleshooting

    Absolute Encoder Counter Overflow Alarm on a Servo Drive

    Alarm 41, absolute encoder counter overflow, means the multi-turn revolution counter passed its specified limit. Check real overtravel and the encoder parameter set first, then cable and supply, then reinitialize the position reference with the drive's documented function and power-cycle. Clearing the alarm without fixing what feeds the count only postpones the next stop.

    Servo and stepper motion

  • Troubleshooting

    Absolute Encoder Error Persists After Battery and Encoder Replacement

    When an absolute-encoder alarm survives a new battery and a new encoder, stop buying parts and split the chain: verify 3.6 V at the encoder-side battery connector, continuity-check the cable and shield, confirm the controller interface, then run the documented mastering or initialization the axis needs after any encoder swap.

    Sensors, encoders and machine vision on the machine

  • Troubleshooting

    Fix Servo Travel Error After Swapping Resolver and Encoder

    Travel that does not match the position display after a resolver-to-encoder swap is a scaling fault: the drive or the technology axis is still converting counts with the other feedback's increments per revolution. Measure one commanded move and divide actual by displayed travel; a constant ratio equal to the resolution ratio names the encoder data. Fix both layers, re-home, then re-tune.

    Servo and stepper motion