Servo drive shows COM fault then overload: check U V W phasing first
Short answer
Clear the COM- control-reference fault before anything else: a jog commanded through an open common proves nothing. Then land U, V and W from the motor datasheet before swapping any pair of wires, because an overload code during jog with nothing connected points at the phase-to-encoder sequence, and one documented two-wire swap is the only phase experiment worth making.

On this page
- Why does a servo drive show COM- and overload faults together in jog mode?
- Which fault do you clear first: COM- or overload?
- What does the COM- check cover on the jog wiring?
- How do you verify U, V and W before swapping wires?
- Why does an overload code appear with no load connected?
- Is swapping two phase wires a valid test?
- What proves the jog repair is finished?
- Questions asked
A servo drive that reports a COM- reference fault and then an overload during jog is reporting two separate problems, and the order you answer them decides how fast this repair goes. Clear the control-reference fault first: a jog commanded through an open common proves nothing about the motor. Then land U, V and W exactly as the motor datasheet maps them to the drive terminals before you swap a single wire, because an overload code with nothing coupled to a geared motor points at the phase-to-encoder sequence, not at mechanical load. The sequence below was worked out on a Leadshine LD5-400 driving a geared permanent-magnet motor rated 36 V, 3000 rpm and 200 W, and it ends with a decision: the code that returns after corrected wiring tells you which side of the wiring still owns the fault.
Why does a servo drive show COM- and overload faults together in jog mode? #
Because the display is stacking two independent faults: the jog circuit's COM- common reference is not seen by the drive, and the overload that appears once jog is commanded is a current-limit trip with nothing coupled — pointing first at the phase-to-encoder mapping, afterwards at feedback and gears.
The installation behind this article showed exactly that pair: the reference code, 1A1 — paired on this drive family's fault list with the COM- control input — stood before any motion was commanded, and 100, the overload code, followed each jog attempt. The drive vendor's setup software would not jog either, which matters: the fault is not tied to one command path, it sits in wiring and feedback that every path shares. Fault lists do not transfer between drive families — one family's manual codes over-current as 0001 and over-voltage as 0002 — so take both meanings from the manual for your exact drive before acting on them.
Which fault do you clear first: COM- or overload? #
Clear the COM- reference fault first, before any phase wire or parameter changes. A jog through an open control common is not a valid phasing test: the drive can reject or truncate the command, so an overload read in that state may be an artifact, not the motor.
Work the pair cheapest-first, the same order you would use when a servo axis faults mid move: wiring that costs nothing to inspect before parameters, parameters before parts. In this case the order also protects the evidence — the installation had already spent its free swap, a single exchange of the V and W leads, after which the overload code stayed, so every further permutation would only blur which combination produced which code.
- Prove the supply dead and inspect the COM- reference circuit end to end.
- Land U, V and W from the motor datasheet; verify the encoder pinout in the same sitting.
- Power up and record which code stands before any command is given.
- Command a short jog and record the first code that returns and whether the shaft turns.
- Only if direction is the last open question, make one documented two-wire swap and retest.
What does the COM- check cover on the jog wiring? #
COM- is the common return of the drive's control-reference circuit, and the code says that return is not seen. Lock the 36 V supply out, verify it dead at 0 V, then check the COM- terminal's conductors, each input sharing that common, and the return to the command source.
Read the drive's wiring chapter and match what you find to its diagram; the needed reference connection is not inferable from the fault text alone. The checks that find this fault in practice: continuity of the COM- conductor end to end, its landing in the correct terminal rather than an adjacent one, the command source's reference actually tied to COM- instead of floating, and terminal screws torqued on stranded leads. On this installation the motor leads are discrete wires rather than a keyed plug — the arrangement where one lead lands one position off most easily — so label every lead before it leaves its terminal. One safety note belongs exactly here: prove the circuit dead before opening any of it, using the supply verification above plus the manual's wait for the internal capacitors to discharge.
How do you verify U, V and W before swapping wires? #
Identify each motor lead from the datasheet, not its position or color, and land it on the matching drive terminal. The requirement is not negotiable: vendor guidance for this drive family says the motor phases U, V and W must be corrected to the drive before further setup.
Pull the datasheet for the exact motor and match its U, V and W lead markings to the drive's output labels one lead at a time. While the cabinet is open, verify the encoder cable pinout against the same wiring chapter, because the drive reads phase order and feedback angle together: a correct phase map with a wrong feedback assignment trips the same way.
The confirming test after landing the documented mapping: power up, note which code stands, command a short jog, and watch the shaft. A shaft that locks with a hum and climbing current says the mapping is still wrong; a shaft that runs smoothly but opposite to the command says the direction relationship is inverted, which many drives answer with a documented feedback-direction setting rather than another wire swap.
Why does an overload code appear with no load connected? #
Because an overload code on a servo drive is a current-limit trip, not a mechanical-load measurement. With wrong phase-to-encoder mapping the current vector lands against or across the rotor's field, the motor stalls or shudders while drawing far more than commanded, and the drive reports overload with nothing coupled.
Nothing coupled outside is not nothing connected: the gearbox is still in the torque path. Eliminate it cheaply first — supply off, motor shaft turned by hand through a full revolution — before blaming electronics; binding or grinding sends the gear stage to inspection ahead of the wiring. Then the electrical candidates in order: the phase map above, the encoder cable, where miswired counts or a swapped complement make commutation fight the rotor, and the jog-mode current and acceleration settings.
Split the symptom by what the shaft does during the attempt. A twitch, a hum and an immediate trip is the mapping or feedback signature; a shaft that accelerates and trips partway into the ramp belongs to the profile — the trip covered in why a servo faults when acceleration ramps increase. A clamp meter on one motor lead during the attempt turns the guess into a number: compare the measured current against what the jog command asks for, the same current-side logic used when a servo drive trips an overload alarm mid cycle under load.
Is swapping two phase wires a valid test? #
One two-wire swap is a valid direction test — swapping any two of U, V and W flips the rotation — but it is the last check, made from a documented starting arrangement, never a random permutation. Three leads allow six combinations, and permuting them destroys the evidence.
The physics is symmetric, which is why the trick works from either wrong arrangement: reversing any two of the three connections reverses the field sequence the drive applies, and why swapping any two of three phases reverses a three-phase motor walks that sequence step by step. On an encoder-commutated servo the same swap tests the phase-to-feedback relationship, which is the relationship this fault is about.
The case had already spent its swap: V and W exchanged, supply restored, jog commanded, and the overload code returned. That result carries information — the mapping was still wrong in the swapped arrangement, or the fault lies outside the phase map entirely. Either way the next move is the datasheet identification above, not a second pair exchange; blind permutations across all six combinations leave you unable to say which arrangement produced which code.
What proves the jog repair is finished? #
The drive accepts jog from its normal command path, the shaft turns smoothly in the commanded direction, neither code returns across a full test session, and jog current sits near the small demand of an unloaded gearbox. All four, or keep working the sequence.
Test through the real command path — the same input or screen an operator will use — not only the setup tool, because this fault sat in wiring shared by every path. Run the jog long enough to cross the acceleration ramp and hold steady speed; a repair that survives only the first half-second is not a repair. If a code returns after the reference circuit, phase map and feedback assignment have all been verified, stop and escalate to the drive vendor's support channel with the wiring evidence and the fault order as displayed.
The decision, stated once for both cases: the reference code standing alone means the control common; overload on jog with the reference verified means the phase-to-encoder map; overload in both phase arrangements with the map verified means feedback wiring, then jog parameters, in that order.
Questions asked
How many wiring arrangements can three motor phase leads have?
Six. U, V and W can land in six permutations, and swapping any two leads moves you between two sets of three that turn opposite ways. That is why one datasheet-verified arrangement plus at most one two-wire swap covers every case, while trial and error across all six leaves you unsure afterwards which combination was actually tested or what each code meant.
Can an open COM- common damage the drive?
Unlikely. A control common is a low-energy logic reference, and left open it normally stops the drive from accepting commands rather than stressing any hardware. The real cost is diagnostic: every jog result recorded while that code stands is unreliable, which is exactly why the reference circuit gets repaired and cleared before any phase or parameter work begins.
What does the gearbox add to this fault picture?
It stays in the torque path even with nothing coupled outside, so it can mask or mimic a mechanical problem. With power locked out, turn the motor shaft by hand through a full revolution: free, smooth rotation with light, even detent clears the gear stage, while grinding or hard spots send the gearbox to inspection ahead of any further electrical testing.
What goes to the drive vendor's support channel if the codes return?
The motor datasheet, photos of the power and control terminals as wired, the fault codes in the exact order the display showed them, the jog parameters as set, the encoder pinout, and which U/V/W arrangement is currently landed. That packet lets support check the phase and feedback mapping against their documentation in a single pass instead of another round of swaps.